PMT14-02099 City of Menifee Permit No.: PMT14-02099
29714 HAUN RD. Type: Residential Electrical
'�i�CELA MENIFEE, CA 92586
MENIFEE Date Issued: 0811812014
PERMIT
Site Address: 29132 ABELIA GLEN ST, MENIFEE, CA Parcel Number: 333-632-016
92584 Construction Cost: $10,689.60
Existing Use: Proposed Use:
Description of SOLAR- 16 PANELS 4.24 KW LOT 69
Work: MASTER PLAN CHECK PMT14-00706
TR 31582-1
Owner Contractor
LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ALISO VIEJO, CA 92656
Applicant Phone: 9493498000
JEREMIAH ACAYTURRI License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description 011Y Amount
'o I i"I" ro IL r�hrd' 6 .
Building Permit Issuance 1 27.00
G EEWIN1'.0^
SMIP RESIDENTIAL 1 2.00
$282.00
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work Is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bidg_Permit Template.rpt Pagel of 1
CITY OF MENIFEE PLCK No: �tp
29714 Haun Road �1, 1
Date: tAMOUnt:
`�
Menifee, CA 92586 1 1 l
Phone: (951)672-6777 Amount:Fax:(951)679-3843 �Ck#: Ism
Building Combination Permit phase 3 - Sum rn I_�
To Be Completed By Applicant
Legal Descnphon: Menifee Hills / El Dorado T31582-1 I
Planning Case: F: L: Rt: R:
Property Address: Lot 69 29132 Abelia Glen St Assessor's Parcel Number. 333 632 016
Project/Tenant Name: Unit#: Floor#:
T 31582-1 - Menifee Hills- Summit
Name: Lennar Homes of California, Inc Phone N§51-817-3680 JFaxNo. _
Property Address: Unit Number Zip Code
Owner 980 Montecito Dr. Suite 302 Corona CA g
Email Address: ,
eremiah.aca urri lennar.com
Name: Phone No. Fax No.
Jeremiah Acayturri 51-403-3715
Applicant Address: same as above Unit Number Zip Code
Email Addmss: jeremiah.acayturri@lennar.com
Name: Phone No. Fax No.
Contractor Address: City State Zip Code
Contractor's City Business License No. Contractor's City State of California License No- Classification: B
Number of Squares:
Square Footage 4.24 kW/ 16 PCS / 16 PCS
Description of Work: Solar PI 404 Elevation A- Reverse Cost of work:$10689.60
Applicant's Signature Date:
7/25/2014
To Be Sp6pieted By City Staff Only
Indical s R-Received or N/A-Not Applicable
5 Completes sets of fully dimensioned,drawn to sale plans which include: 1 set of documents which include
❑ Tille Sheet ❑ Elevations ❑ Electrical Plan ❑ Geo Tech/Soils Report(on cd only)
❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8 Y x 11)
❑ Foundation Plan ❑ Structural Calculations
❑ Cross Section ❑ Plumbing Plan ❑ Single Line diagram for elec.services over 400 AMP
❑ Floor Plan ❑ Structural Framing Plan 8 Details ❑ Shoring Plan 1 ❑ Sound Report-Residential
Class Code: Indicate I New Construction Alteration' Addition' Means/Methods
Work Type: I Repair' RetrofiH ReNsion to Existing Permit' Required? YES NO
Proposed Building Use(s): Existing Building Use(s):
#Buildings: #Units: ff Stories: Will the Building Have a Basement?
Y of N
Bldg-Code Occupancy Group Indicate Indicate if Indicate all Geo-tech.Haz.Zone
At Project Sprinklered YES or NO
Completion: Constroction that apply: Coastal Zone
Type(s): C Of O YES or NO Noise Zone
Requiretl? Listed on Historic Resources Inventory
CITY PLANNING STAFF ONLY
APPROVALS: Costal Commiss Arch-Review Board Landmark Comm. Planning Comm.Zoning Administrator
Fee Exempt: City Project Elea Vehicle Charger Landmark Seismic Retroft special case:6lag.
OmoalA roval
Expedite Project(s): Child Care City Project I IGreen Building Landmark ASordable Housing
For Staff Use Only
Building/Safety I Permit Specialist City Planning I ,v,,Engineering I EPWM-Admin Transportation Mgmt. I Rent ConWI
THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM CITY PER. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE I 4.24KW I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 16 PCS, BEND I PM250MOI(265W) BUYER:
INVERTER 16 PCS ENPHASE I M2I5-60-2LL-S22-IG
ROOF TYPE TILE W7 COMPOSITE SHINGLE UNDER ARRAY DATE:_____—__ —_ —_______ -
SUR-ARRAY INFORMATION
ARRAY#I ARRAY#2 ARRAY#3
MOD CITY I6 N/A N/A BUYER:__—- _—----------------------------
TILT 23° XX° XX°
AZIMUTH I63° XX° XX° DATE
CITY OF MENIFEE
BUILDING AND SAFETY DEPARTMENT
PLAN APPROVAL
ED B 4'- 4 b
DA
'Approval of these pla s sh II not be construed to be a permit for,or an
t approval of,any violat n cif:Tnh
y pr i°s L 414J19cleral,state or city
regulations and ordinances,. ' set oTapprD�RF�'plans must be kept on
jobsite until completi ,
t -
7 i
11 L — _. —— —
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
�} MAIN SERVICE PANEL
I/ (VERIFIED BY BUILDER)
` '
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
N
PLAN 3404 ELEVATION A-REVERSE
ORIENTATION 3 LOT#69
SUMMIT AT MENIFEE LENNAR: ORIGINAL BY. DESIREE WILLIAMS DATE:14.7.17
980 MONTECITO DRIVE REVIEWED BY:TOM FIBRES DATE-14.7.17
HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION
VnanncISt;6
SOLAR
vet
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4577 Brodel.CO y Street
PLOT PLAN I I/16'=1'-0" 29132 ABELIA GLEN STREET Bo333 C080004
SYSTEM LAYOUT MENIFFEE,CA 303:44].0300
x
r
P /
� I
R
CO
I 4 1 F 7
N
PLAN 3404 ELEVATION A-REVERSE
ORIENTATION 3 LOT#69
SUMMIT AT MENIFEE LENNAR: ORIGINAL BY: DESIRES WILLIAMS DATE 143717
980 MONTECITO DRIVE REVIEWED BY:TOM CODES DATE.11.7.17
HILLS CORONA,CA 92789 REV# BY DATE DESCRIPTION
Vnamast6
DING TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Brwftay Street
PLOT PLAN 2 I/64"=1'-0" 29132 ABELIA GLEN STREET Boulder,CO 80304
MENIFFEE.CA 3034470300
SITE PLAN
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASTRAL 2% "C 37 INV. MODEL INVERTER SPEC M215-60-2L1_-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN "C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(Ac) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INV, INPUT V.(Voc MAX) INVERTER SPEC VOLTS Wc) 48
TEMP,DELTA LOW(ToeLTA) THIN-TTEST °C -27 INV. OUTPUT V,(VAc MOM) INVERTER SPEC VOLTS(AC) 240
MOD,MANUFACTURER MODULE SPEC BENS INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC PM250M01 INV. OUTPUT CURRENT, IAc INVERTER SPEC AMPS(AU 0.9
MOD.POWER STC BE) MODULE SPEC WATTS(Dc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I
MOD,OPERATING VOLTAGE (VMP) MODULE SPEC VOLTS(ac) 31.30 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD,OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(oc) 38.20 INV. GROUNDING INVERTER SPEC ISOLATED
MOD, CORER. VOLT/TEMP(COEE) MODULE SPEC V/°C -0.115 INV.STY,MAX/BRANCH OCT. INV.OTYec OTY 16
MOD. MAX VOLTAGE(VNAxnoo) (Voc i(To`LOEF)) VOLTS(oc) 41L31 BRANCH OCT.OUTPUT,IMAXBC (IAC'INV.QTYec) AMPS(Ac) 1 14.40
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(ac) 8.47 INV.QUANTITY,TOTAL INV.QTYT QTY 1 16
MOD.SHORT OCT. CURRENT(15c) MODULE SPEC AMPS RrE 8.98 TOTAL SYSTEM OUTPUT, IMAXTS (IAC-INV.QTYT) AMPS(AC) 14.40
MOD. MAXIMUM CURRENT(IMAX) (Isc. 1.25) AMPS(oc) 11.23
MIN,AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(oc) 14.03
SERIES FUSE RATING,MAX MODULE SPEC AMPS(or) 15
ELECTRICAL EQUIPMENT SCHEDULE
.KEY STY MANUFACTURER MODEL NOTES TRADE
I 16 BEND PM250MOI(265W) PV MODULE SOLAR
2 16 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URD PV AC DISCONNECT,NEMA 3R. 240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x ISATP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 TBD TBD SERVICE PANEL,MIN. 125A BUS HLDR.ELEC.
11 TBO TBD UTILITY METER, IPH, 120/240V.200A PLDR.ELEC.
12 1 TBD I TBD GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): (AMPACITY.TEMP.DEBATE °FILL BERATE) vs.NEWS(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REQ'D,(IMAX°1.25) PANEL MFR- CUTLER-HAMMER
KEY $1ZEW'NSULACAL6. AMPACITY W/0 TEMP. FILL RESULT REQ'O OCD BUS RATING AMPS 200
TYPE DEBATES DERATE BERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A COU 30 M61122,80 14,40 ALLOWED PV PER NEC AMPS 40
TERM 2525 I8.00B COU 40 36.40 14.40TERM 3535 18.00 20
C COU 40 3640 1440TERM 3535 18 AO 20
CONDUCTOR SCHEDULE
KEY I CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENGAGE CABLE. -#6G.FREE AIR CU TO ER ARRAY SOLAR
H I 3-#IQ 1-#10 EGC CID NM-B(ROMEX) I INTERIOR I SOLAR
C 1 3-#10,1410 EGC CID NM-B(ROMEX) I INTERIOR I SOLAR
O I CATSE,ETHERNET CABLE CU CAT5E I INTERIOR I SOLAR
II 6 5 0
M o o eO
0
SEE
NOTE 15
O QISA/IP
Q
�aA,zF i O O
a O
i = -- --
_ e
12
I I I
EXTERIOR-GARAGE ROOF
ELECTRICAL DIAGRAM 4.24KW
LOT#69
SUMMIT AT MENIFEE LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:14.7.17
REVIEWED BY:TOM FIBRES DATE:14.7.17
HILLS 980 MONCORONA,CEAC19O DRIVE 2789 REV.# BY DATE IDESCRIPTIONVnI
Borne
DWG TITLE: PAGE#. SCALE: SITE LOCATION:
INDIVIDUAL 4671 Broadway Street
PLOT PLAN 3 NTS 29132 ABELIA GLEN STREET Boulder,C080304
ELECTRICAL MENIFFEE,CA 303,447.0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227-3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH HJ)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3".
2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT N')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU,
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS.LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE ULO03, IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR
-
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J".
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED°PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY III
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
SUMMIT AT MENIFEE LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:14.7.17
REVIEWED BY:TOM FIDDES DATE:14.7.17
HILLS 980 MONTECITO DRIVE REV.# BY DATE DESCRIPTION
CORONA,CA 92789 Vnamasrd
SOL/R
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
tmet
INDIVIDUAL 4571 ,,D 80304
PLOT PLAN 4 NTS 303 cl. ay 304
29132 ABELIA GLEN STREET BaO
MENIFFEE,CA 03.447.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY
THE UTILITY AND A SOLAR PV SYSTEM.
DISCONNECTS ARE LOCATED AS SHOWN.
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER B
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
SUMMIT AT MENIFEE LENNAR: ORIGINAL BY: DESIREE WILLIAMS I DATE 14.7.17
980 MONTECITO DRIVE REVIEWED BY:TOM FIDDES DATE 14.7.17
HILLS CORONA,CA 92789 REV.# BY DATE DESCRIPTION
namaste
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadvay Street
PLOT PLAN 5 NTS 29132 ABELIA GLEN STREET Boulder,CO 80304
MENIFFEE,CA 303.4 7.0300
PLACARDS