Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT14-01282
City of Menifee Permit No. PMT14-01282 29714 HAUN RD. Type: Residential Electrical 9;kccr=.A. MENIFEE,CA92586 MENIFEE Date Issued. 07I10I2014 PERMIT Site Address: 29039 ABELIA GLEN ST, MENIFEE, CA Parcel Number: 333-631-036 92585 Construction Cost: $10,689.60 Existing Use: Proposed Use: Description of ROOF MOUNTED SOLAR, 12 PANELS, 3.18 kW Work: MASTER PLAN PMT14-00706 -- TR 31582-1 Owner Contractor LENNAR HOMES OF CALIFORNIA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE 25 ENTERPRISE SUITE 302 ALISO VIEJO, CA 92656 Applicant Phone: 9493498000 980 MONTECITO DRIVE License Number: 728102 SUITE 302 CORONA, CA 92879 Fee Description G1yt Amount l$1 Solar, Residential or Small Commercial ». 1' " '; ti„`. q '152.00 Building Permit Issuance 1 27.00 GREEN FEE .w., ....:u �.,_. r.. „ , . 1 !. f_ 1.00 SMIP RESIDENTIAL 1 2.00 $282.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. --W �U tJ AA_Bldg Permit_Template.rpt Page 1 of 1 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE LOCATIONS INDICATED BY THE ILLUSTRATION. SYSTEM SIZE 3.18KW MODULE 12 PCS. I BEND I PM25GM01(265W) BUYER: --- INVERTER 12 PCS. IENVKASE 1 M215-60-2LL-52Z-IG ROOF TYPE TILE W1 COMPOSITE SHINGLE UNDER ARRAY DATE_ ____— ------ SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 1 ARRAY#3 MOD OTY 12 NA NA BUYER:_—____ TILT 23° 1 NA' I NA• DATE:-------- ___ R❑I�fJln(] & Sat@{Y Deft. AZIMUTH 271° 1 NA' I NI DEC 1 8 .2014 Received i I I = o I � I I � ' I I I I I 1 a I P I I ' I I I I I I I I I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) CITY OF &JENI EE PV AC DISCONNECT BUILDING AN SAF EXTERIOR-GARAGE UTILITY METER 8 PLAN MAIN SERVICE PANEL APPROV L (VERIFIED BY BUILDER) I I REVIEWED BY I � I L—— — — `Aporoval of these plans sh II not 61 approval of,any violation of n regulations and ordinahces, in set johsite until completion. is set NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION C ORIENTATION 3 LOT#83 N ORIGINAL BY: STACEY MCKINNEY I DATE:14.6.15 LENNAR: SUMMIT AT REVIEWED BY:TOM FIDDES I DATE:14.6.15 980 MONTECITO DRIVE REV.k BY DATE DESCRIPTION MENIFEE HILLS CORONA,CA92789 Vnc3masl;6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29039 ABELIA GLEN STREET Boulder,CO 80304 PLOT PLAN 1 1116-=1'-O' MENIFEE,CA 303447'0300 SYSTEM LAYOUT City of Menifee Building & Safety Dept, DEC 18 2014 Received ABEUA GLEN STREET 0 d DE strued 1 s of tht proved N PLAN 2686 ELEVATION C ORIENTATION 3 LOT#83 NNAR: ORIGINAL BY. STACEY MCKINNEY DATE:14615 SUMMIT AT REVIEWED BY:TOM HOPES DATE:IL.6.15 9BO MONTECITO DRIVE REV.# BY DATE DESCRIPTION • I`': / MENIFEE HILLS CORONA.CA02789 t n1.maivy eoue DWG TITLE PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29039 ABELIA GLEN STREET Boulder,CO 80304 PLOT PLAN 2 1/64"=1'-0" MENIFEE,CA 303,4470300 SITE PLAN MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE]CALC UNIT DETAIL ITEM NOT ER E]CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °G 37 INV.MODEL INVERTER SPEC 225 215-b0-2LL-S22-IG TEMP,AMBIENT LOW(TMIM) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAc MAX) INVERTER SPEC WATTS(AC) TEMP,MODULE TEST(TiBsi) MODULE SPEC "C 25 INV. INPUT V,(Vac MAX) INVERTER SPEC VOLTS(DU 4B TEMP,DELTA LOW(TDELTA) THIN-TTESi 'C -27 INV. OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS UU 240 MOD. MANUFACTURER MODULE SPEC BEND IN OUTPUT FREQUENCY INVERTER SPEC IHERTZ 1 60 MOD. PART NUMBER MODULE SPEC PM250MOI IN OUTPUT CURRENT,lac INVERTER SPEC AMPS(ac) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS WE) 265 INV,PHASE QUANTITY INVERTER SPEC PHASE MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS I—) 31.30 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 ISOLATED MOD.OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(Dc) 38.20 INV.GROUNDING INVERTER SPEC MOD.COEFF.VOLTYTEMP(CDEF) MODULE SPEC V/"C -0.115 INV.OTY,MAX/BRANCH CCT. IN¢QTYec OTY 12 MOD. MAX VOLTAGE(VMAXMOD) (Voc�(TD'COEF)) VOLTS(DO) 4L31 BRANCH CCT.OUTPUT,IMAxec (Iac9NVATYeU AMPS(AU 10.80 MOD.OPERATING CURRENT(INP) MODULE SPEC AMPS(DC) 8.47 INV. QUANTITY,TOTA INV.UTYT OTY 12 L MOD.SHORT CCT.CURRENT USE) MODULE SPEC AMPS(00 8.98 TOTAL SYSTEM OUTPUT,InaxTs (lac'INV.OTYU AMPS(Ac) 10.80 MOD.MAXIMUM CURRENT(IMAX) (Isc•1.25) AMPS(DO 11.23 MIN. AMPACITY REU'U,PER NEC (IMAX° 1.25) AMPS(GE) 14A3 SERIES FUSE RATING,MAX MODULE SPEC AMPS(Dc) IS ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 12 BENG PM250M01(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC]SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,2404,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR b TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV UATA MONITOR I SOLAR ] TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBO PV BRANCH CIRCUIT BREAKERS;I X.ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,IPH,120/240V.2004 BLDR.ELEC. 12 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF L 1C , (AMPACITY°TEMP.DEBATE-FILL GERATE) VS.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM) AMPACITY AT TERMINALS- VS. REO'D.UMAY°I.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DEBATES GERATE DEBATE C4) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 CO U 30 .76 L0 22.80 10,80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS I 20 B #10 CU NM-B COU 40 .91 1.0 36.40 10.80 TERM 35 35 13.50 20 C #10 CU NM-B COU 40 .91 1.0 36,40 10.80 TERM 35 35 13.50 20 WCATSE, R SCHEDULE ORS CU/AL TYPE LOCATION TRADE ^D AGE CABLE, 1-#6G,FREE AIR CU IL-ER ARRAY SOLAR \nI 10 EGC CU NM-B(ROMEX) INTERIOR SOLAR n 10 EGC CU NM-B(ROMEX) INTERIOR SOLAR City of Menitee THERNET CABLE CU CATSE INTERIOR SOLAR Building & Safety Dept. II 6 5 D DEC 18 2014 O o o •Q7 SEE Received 10 NOTE 15 © 4 5AIP ea Pi M 3 O O feral, 204/3P 2 4 Ins m 4 12 EXTERIOR-GARAGE ROOF ELECTRICAL DIAGRAM 3.I8KW LOT#83 EEORIGINAL BY: STACEY MCKINNEY DATE:14.6.15 SUMMIT AT ELENNAR: REVIEWED BY:TOM FIDDES DATE:14.6.15EGLEN E REV.# BY DATE DESCRIPTIONMENIFEE HILLS V namasb6 'ADWG TITLE: PAGE#: SCALE: 4571 BmatlwaY Street INDIVIDUAL STREET BO21CG. C080004PLOT PLAN 3 NTS 3034470300 ELECTRICAL STRUCTURAL NOTES, SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(F)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PMoof Menifee INSTALLATION. Building & Safety Dept DEC 18 2014 Received ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH, PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM, 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS, WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. SIGNAGE- 12)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 13)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.14)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF 7 I� EN, MINIMUM HEIGHT J'. IS)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL CONTRACTOR- 161INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 17)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 18)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 19)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 20)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET FOR ENPHASE ENVOY MONITOR. ��41 it for,o Ite or ei. be kept ORIGINAL BY: STACEY MCKINNEY I GAT SUMMIT AT LENNAR: E 14.fi.15 REVIEWED BY:TOM MIDGES DATE:14.6.15 980 MONTECITO DRIVE REV.# BV DATE DESCRIPTION MENIFEE HILLS CORONA,CA92789 namasGi& .o,.. DWG TITLE: PAGE k: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29039 ABELIA GLEN STREET Boul&r,CO B0304 PLOT PLAN 4 NTS MENIFEE,CA W3,M7.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. City of Menifee Building & Safety De t. DEC 18 2014 Receive 1 EERIER Eoea -EL SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP ttt 1-877-SLR-POWR i the NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: STACEY MCKINNEV DATE:14.6.15 SUMMIT AT LENNAR REVIEWED BY.TOM FIDDES DATE 14.6.15 9BO MONTECITO DRIVE REV.# By DATE DESCRIPTION MENIFEE HILLS CORONA.CA92789 �anamasud OIL. DWG TITLE: PAGE Sr. SCALE. SITE LOCATION. 4571 BroarE vAy Street INDIVIDUAL 29039 ABELIA GLEN STREET Boulder, PLOT PLAN 5 NTS MENIFEE.CA 30344'l.0300 PLACARDS