Loading...
PMT14-00990 City Of Menifee Permit No.: PMT14-00990 29714 HAUN RD. ';kCCEL.P MENIFEE, CA 92586 Type: Residential Electrical e.Ablt, ' MENIFEE Date Issued: 05/02I2014 PERMIT Site Address: 29788 TIERRA SHORES LN, MENIFEE, Parcel Number: 340-500-010 CA 92584 Construction Cost: . $47,500.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR PV SYSTEM, 38 MODULES,2 INVERTERS, 9.5 kW Work: Owner Contractor MARY& DAVID BILLINGS AMERICAN SOLAR DIRECT INC 29788 TIERRA SHORES LANE 11766 WILSHIRE BLVD STE 500 MENIFEE, CA 92584 LOS ANGELES, CA 90025 Applicant Phone: 4242146700 AMERICAN SOLAR DIRECT INC License Number: 941069 217 N SUNSET AVE CITY OF INDUSTRY, CA 91744 Fee Description Glyl Amount($ SA -RoSidenflalO §mll Co erl, �5p pp Building Permit Issuance 1 27.00 Additional:'Flan Revlevy Electrical 120 129(i7 GREEN FEE 1 2.00 SMtP RE 8165NTIA4 1 500 $415.07 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated, a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Permit Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and Professions Code and my license is in full force and effect. contractors to construct the project(Section 7044, Business and Professions License Class (f(6 e4 License _ y46 Code;The Contractor's License Law does not apply to an owner of a property 5 who builds or improves thereon, and who contracts for the projects with a Expires r Signature licensed contractor(s)pursuant to the Contractors State License Law), WORKERS'COMPENSATION DECLARATION ❑ I am exempt from icensure under the Contractors'State License Law for the ❑ I hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' compensation,issued by the Director of Industrial Relations as provided for by BY my signature below acknowledge that, except for my personal residence in Section 3700 of the Labor Code, for the performance of work for which this which I must have resided for at least one year prior to completion of permit is issued, improvements covered by this permit, I cannot legally sell a stricture that I have Pol # built as an owner-building if it has not been constructed in its entirety by licensed 7 contractors. I understand that a copy of the applicable law, Section 7044 of the I have and will maintain workers' compensation insurance, as required by Business and Professions Code,is available upon request when this application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:htt /Iwww.le fo.ca,aov/calaw.html. permit is issued,My workers'compensation insurance carrier and policy number are: Carrier �� ' / P roperty Owner orAuthonze Agent —{��p�-�.�n �Cq' n Date Expires_ f� Jf/ Policy# )J 6,f1,6'}�rj6('"�`�/ L Name of Agent w`xZrt _Phone# �' my Signature below, I certify to each of the following: I am the property _ owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for application and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building construction. I uthortze rs presen�eives of this city or county to enter the above- 0 1 certify that in the performance of the work for which this permit is issued,I id rflTa�,pr ,ty for the'3Ra Gan pur sea.shall not employ any persons in any manner so as to become subject to the J/ workers' compensation laws California, and-agree that if should become -�—�— subject to the workers'compensation provisions of Section 3700 of the Labor v Code, I shall forthwith comply with those provisions. Rrop_e-y Owner or utho ized Agent Date Date; Applicant; City Business License# WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL HAZARDOUS MATERIAL DECLARATION SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($700,000), IN ADDITION TO THE COST OF COMPENSATION, WILL THE APPLICANT OR FUTURE BUILDING DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE DYES OCCUPANT HANDLEAHAZARDOUS MATERIAL ORA LABOR CODE,.INTEREST,AND ATTORNEYS FEES - MIXTURE CONTAINING A HAZARDOUS MATERIAL CONSTRUCTIONLENDINGAGENCY _ ONO EQUAL TO OR GREATER THAN THE AMOUNTS SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? - agency for the performance of the work which this permit is issued (Section 3097 Civil Code) WILL THE INTENDED USE OF THE BUILDING BY THE Lender's Name APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE DYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION Lender's Address FROM THE SOUTH COAST AIR QUALITY MANAGEMENT ❑NO DISTRICT(SCAQMD) SEE PERMITTING CHECKLIST FOR OWNER BUILDER DECLARATIONS GUIDE LINES I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: ' License Law for the reason(s)indicated below by the checkmark(s)I have placed DYES next to the applicable item(s) (Section 7031.5, Business and Professions Code: WILL THE PROPOSED BUILDING OR MODIFIED FACILITY Any city or county that requires a permit to construct, alter, improve, demolish, ❑NO BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A or repair any structure, prior to its issuance, also requires the applicant for the SCHOOL? permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law(Chapter 9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption. Any DYES violation of Section 7031.5 by any Applicant for a permit subjects the applicant to CHECKLIST. UNDERSTAND MY REQUIREMENTS a civil penalty of not more than ($500).) D NO UNDER THE STATE OF CALIFORNIA25533,AND AND SAFETY ❑ I, as owner of the property, or my employees with wages as their sole CODE, SECTION MATERIAL 25533 AND 25534 CONCERNING HAZARDOUS MATERIAL(1iEPORI'ING. compensation, will do ( )all of or( ) porting of the work, and the structure is PROPERTY OWNER OR AUTHORIZED AGENT not intended or offered for sale. (Section 7044,Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property X who, through employees' or Personal effort, builds or improves the property, provided that the improvements are not Intended or offered for sale. If,however, the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or Improved for the purpose of sale). CITY OF MENIFEE City of Menifee PLCK No: Permit No: 29714 Haun Road Building & Safety Dept. 0 Date: Date: Menifee, CA 92586 MAY 0 1 2014 6111ILt Phone: (951)672-6777 Amount -tom, Amount: Fax:(951)679-3843 Received ck#c:�llJ� ck#: Building Combination Permit To Be Completed By Applicant Legal Description: Planning Case: F: L: Rt: R; Prop¢ttyr�dy�s�j,� �. Assessor's Parcel Number. �cJJ.• l // as cS Lciilr Projecu tenant Name: Floor#: Na 714 4� el U r. _/ N S P e No.11. Fax No. _ Owner Add/re�ss� Unit Number �✓ Zip Cod � lr��r � ore L P Email Address: Noma: k U Ke q�� pp. Addr � � �N�-`l t7 0 -Jrt( lFaEx No.Applicant C��J,t j., �VUnit Number l Email caress:: / V v 'I f er tit ; ,Ib t Pl F Na e: n Phone No. Fax No. l t Contractor dd ss: State Zip Cod / ahsY eve onVactor's ity usmess tcensa o. Contractor's City State of California License No. I I Classification: Clb c�i Number of Squares: Square Footage Description of Work:LNJ{�IIGIgOi � W I� SttJ teiM UD vn�--✓. cost of work:g Applicant's Signature / �. Date: To Be Completed B icy S ff Onlyv Indicate As R-Received or N/A-Not Applicable '— 5'Comptates'sats'bffully dimensioned,drawn to sale plans which include: 1 set of documents which include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Geo Tech/Soils Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8 y:x it) ❑ Foundation Plan ❑ Cross Section ❑ Plumbing Plan El Structural Calculations ❑ Single Line diagram for ales.services over 400 AMP ❑ Floor Plan ❑ Structural Framing Plan&Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code: Indicate I New Construction Alteration` Addition' MeamAlethods Work Type: RePalr• Retrofit' ReNsion to Existing Permit' Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: tr Stories: Will the Building Have a Basement? Y of N Bldg. Code Occupancy Group Indicate Indicate if Indicate all Geo-tech.Haz.Zone At Project Sprinklered YES cr NO Completion: Construction that apply: Coastal Zone Type(s): Coro YES or NO Noise Zone Required? Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: I Costal Commiss Arch.Review Board Landmark Comm. [Planning Zoning Administrator Fez Exempt City Project Elec.Vehicle Charger Landmark Seismic Retrofit spac;at ase:Blag. O(fdalA .oval Expedite Project(s): Child Care City Project Green Building Landmark Affordable Housing For Staff Use Only Buildin /Solely I Permit Specialist I City Planning I Civil Engineering I EPWM-Admin Transporlalion rAgml. Rent Control THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY Project: Billings Residence M�r®p ica n fe Date:4/29/2014 29788 Tierra Shores Lane Solar DirectMenifee,CA 92584 Sheet: 1 of 2 Design Scope Design of solar module anchorage to roof of existing type V residential building. City of Menifee Building Codes Building & Safety Dept. IBC 2012,CBC 2013,ASCE 7-10 kNolk Design Data MAY 0 1 2014 #of Stories 2 Full Framing Span 21.5ft Angle of Plane of Roof from Horizontal B= 23deg Framing Size 2Xorss eived Live Load LL= 20 psf Framing Spacing 2 Risk Category II Roof DL Ceiling DL. Individual PV Module Weight W,= 41.9 lbs Tile Roofing 16.0 psf Framing 1.5 psf ` Support Spacing Parallel to Framing 4.00 ft Sheathing 1.6 psf Insulation 1.0 psf Support Spacing Perpendicular to Framing 4.00 ft Framing 2.5 psf Ceiling 2.5 psf PV Module Dimensions L= 64.6 in Misc. 1.5 psf Misc 0.0 psf W= 39.1 in (E)Roof DL 21.6 psf (E)Ceiling DL 5.0 psf Wind Data Components&Cladding(Simplified Method)-ASCE 7-§30.5.2 Mean Roof Height of Building h= 25 ft Wind Exposure Category C ASCE 7- §26.7.3 3-Second Gust Wind Speed V= 110 mph ASCE 7-Figure 26.5-1 Importance Factor(Wind Loads) 1= 1 Building Height&Exposure Adjustment Factor X 1.35 ASCE 7-Figure 30.5-1 0 T &ph is Factor K,i= 1 ASCE 7- §26.8.2 IndQik Module Area A= 17.54ft' ppP LX Roof Zones Interior(1) End(2) Corner(3) ASCE 7-Figure 30.5-1 pg.345 OSTJet Design Win ress G ,3p= -19.4 -31.9 -47.9 psf Out ASCE 7-Figure 30.5-1 pg.346 `_`\( l_ 1�`-cc� ne,= -26.2 -43.1 -64.7 psf Out ASCE 7-(Eq.30.5-1) [ ` \_OC'r ` V PnO30= 11.4 11.4 11.4 psf In ASCE 7-Figure 30.5-1 pg.346 J[`v, of t6(r�ue,= 15.4 15.4 15.4 psf In ASCE 7-(Eq.30.5-1) Is ctural r1Q smic Design C at pt�t�y �Jih¢(Mechan0 Modu ical&Electrical)Components-ASCE 7-§13.3.1 lle Type ReneSola T ^a`O Site e l�§'9�fice gh� bQ�eQ D Inverter Type Solar Edge - �r Spect ,R onse Acceleratjs- hrio ,J Sps= 2.000 Racking System SnapNrack Compo` nP ceaF�2For Ip= 1 Number of Modules 38 Co glnt ifi� Factor ap= 1 Number of Connections 78 ComponO�r `R�'DeDs�pq NSl<pmsfcation Factor RP= 1.5 PV System Weight 1984 lbs PP Comp1 O iOog M `ght per Connection Wp= 25.4 lb/leg PV Array Area 667 ft' CR,& neat\ nt Point with Respect to z/h= 1 Roof Area 2916 ftz *t!�, P� e Re�l�n�(`Q,�ean Height of Structure * Percent Coverage(Area) 22.9 % 1)4 0\a��p0 tG�� Fp= 1.60 Wp lbs ASCE 7-(Eq. 13.3-1) tte `y"CL� Fp(max)= 3.20 *Wp lbs ASCE 7-(Eq.13.3-2) Q1POES8/0A Fp(min)= 0.60 *Wp lbs ASCE 7-(Eq.13.3-3) ��O NJAF/ Fp= 1.60 *Wp lbs h C Seismic Design Force Acting on Component Fp= 40.7 Ibs/leg 12 m Mounting System(Fastener)Mounting System(Fastener)Design �I Maximum Wind Loading A x pie,= 331.6 Ibs Tension * P * Maximum Seismic Loading Fp= 40.7 lbs Shear S'j. C10. Lumber Species Douglas Fir-Larch(North) 9�pF CAUFO�e� Specific Gravity G= 0.49 NDS 2012-Table 11.33A NOS 2012(Dowel-Type Fasteners) 5/16"X 3 1/2"Lag Screws Date Signed: 2 Load Duration Factor CD= 1.6 NOS 2012-Table 2.3.2 Reference Values Design Adjusted Allowable Shear,Parallel-Table 11K ZII= 260 416 lbs/screw > 40.7 ✓ Allowable Shear,Perpendicular-Table 11K Zi= 180 288 lbs/screw > 40.7 ✓ Allowable Tension(Withdrawal)-Table 11.2A W= 258 413 lbs/screw/inch=1032 lbs screw > 331.6 ✓ :• Use 5/16 X 3 1/2 Lag Screws(w/2 1/2 Min Embedment) Project: Billings Residence �� AMeriCan Date:4/29/2014 29788 Tierra Shores Lane Sear Direct Menifee,CA 92584 Sheet:2 of 2 Loading Analysis s Gravity Load Compliance(CBC-§3404.3) 101.5% < 105% :. PV system gravity loads are in compliance. s y Lateral Load Compliance[Seismic](CBC-§3404.4) 102.6% < 110% PV system seismic loads are in compliance. Lateral Load Compliance[Wind](CBC-§3404.4) 145.4% > 110°% :. The adjacent framing ok by inspection for outward lateral loads.Review nailing. c Existing Diaphragm Nailing Analysis r' %► Assumed Plywood Sheathing Thickness 0.5 in Assumed Minimum Diaphragm Nailing 8d Common Nails @ 12"O.C.(All Boundary Edges&Field) Nail Diameter D= 0.131 in NDS 2012-Table L4 Nail Length L= 2.5 in NDS 2012-Table L4 Specific Gravity G= 0.49 NDS 2012-Table 11.3.3A Load Distributed to Adjacent Framing(Each Side) 31 plf Allowable Tension(Withdrawal)-Table 11.2C W= 30 Ibs/nail/inch penetration W= 60 lbs/nail > 31 ✓ The existing roof diaphragm nailing can sufficiently distribute excess loading to adjacent framing. '1.._ Existing Framing Analysis Uplift on Rafter/Truss at Eave&Ridge(Using ASD Load Combination[0.6D+0.6W]) Assumed Rafter/Truss to Plate Nailing 3-8d Toenails CBC-Table 2304.9.1 Nail Diameter D= 0.131 in NDS 2012-Table L4 Nail Length L= 2.5 in NDS 2012-Table L4 Specific Gravity G= 0.49 NDS 2012-Table 11.3.3A Number of Connections per Loaded Rafter/Truss 4 Maximum Wind Loading per Connection A x p°et= 331.6 Ibs ,,,•a� .x Total Uplift on Loaded Rafter/Truss 1326.2 Ibs Dead Load on Tributary Area(3 Rafters/Trusses) 0.6(DL)= 2237.7 Ibs Allowable Tension(Withdrawal)-Table 11.2C W= 30 Ibs/nail/inch penetration Total Allowable Tension-3 Rafters/Trusses W= 361.8 Ibs • ✓ Dead Load on Tributary Area+Nail Capacity 2599.5 Ibs > 1326.2 :• The existing rafter/truss to plate toenailing can sufficiently withstand uplift on the roof rafters/trusses. Assumed Rafter/Truss to Ridge Nailing 2-16d Toenails CBC-Table 2304.9.1 Nail Diameter D= 0.162 in NDS 2012-Table L4 Nail Length L= 3.5 in NDS 2012-Table L4 Specific Gravity G= 0.49 NDS 2012-Table 11.3.3A Number of Connections per Loaded Rafter/Truss 4 Maximum Wind Loading per Connection A x p...= 331.6 Ibs Total Uplift on Loaded Rafter/Truss 1326.2 Ibs Dead Load on Tributary Area(3 Rafters/Trusses) 0.6(DL)= 2237.7 Ibs Allowable Tension(Withdrawal)-Table 11.2C W= 38 Ibs/nail/inch penetration Total Allowable Tension-3 Rafters/Trusses W= 427.7 Ibs Dead Load on Tributary Area+Nail Capacity 2665.4 lbs > 1326.2 ✓ :• The existing rafter/truss to ridge toenailing can sufficiently withstand uplift on the roof rafters/trusses. VICINITY MAP AERIAL VIEW 0op American 1 PN.SE 36 5 P 3t, 340-50 Solar Direct PROJECT DEVELOPER:JAN# AmericanSoIarDin cI Inc. rc AVGUR LICENSE BtC I0/C468941089 NLOB PHGEtEB.GN@5 PH-f4m)214B?0p am:`X(424)21�W hftpj YM'.�. %% z LU w PROJECT z ity Of 'Menifee LOCATION Ui < Bulk Ing & Safety Dep U) %A LU 41 1 U)1.9 LU o 0 Do 0 Z X Lo of LU co 0 U) lIFAAq W Lu SHORES IAN LU w w (6 wNt It u z Do 00 I Lo ROAD 364 , PROJECT NIJMBE w �w w If is "if-73 ho my PROPROJECTTOP-00149111 SU: PROJECT INFORMATION PROJECT SCOPE APPLICABLE CODES SWEET INDEX 9.50KW PV SITE CONTACT: CALIFORNIA BUILDING CODE, 2013 EDITION (CIBC) T TITLE PAGE HEFT Tn1E OWNER: MARY M. I DAVIE) W. 51LUNGS S.54OKU) SOLAR ARRAY CALIFORNIA RESIDENTIAL CODE, 2013 (CRC), CA CUSTOMER APPROVAL/ SITE PLAN PVI ROOF: PLAN TITLE PAGE 213158 TIERRA SHORES LANE (3a) RENE50LA MODULES CALIFORNIA ELECTRIC CODE, 2013 EDITION/.<tEC) PVI.I SYSTEM LAYOUT PV2 LAYOUT + CONNECTION DETAIL MENIFEE, CA, -32584 MODEL NO. JC250M-241155 CAUFORNIA MECHANICAL CODE, 2013 (Ct*fg) E2 SINGLE LINE DIAGRAM CHIEFEI-IiMftl N PH: (1351)-146-419,3 IN (1) STRING Or 10 MODULES t (1) STRING OF: 11 CAUFORNIA PLUMBING CODE, 2013 (CPC) 4,T E2.1 LOAD CALCULATIONS T DANNYMCINTYRE APN: 340500e10 MODULES ON (1) SOLAR EDGE INVERTER. ARTICLE &SO, NEC 24911 CODE 500K E3 SIGNAGE I TITLE 24 RESIDENCE ENERGY EFFICIENCY STANDARDS DI RACKING SYSTEM SPECIFICATIONS (424) 214-6700 CHIEF ELECTRICIAN: MODEL NO. 5E500&A-US (240V) D2 INVERTER SPECIFICATIONS Signatum-Danny Mclnqm DANNY MCINTYRE IN (1) STRING OF: 11 MODULES ON (1) SOLAR EDGE CAL-FIRE PHOTOVOLTAIC INSTALLATION GUIDELINES D3 PANEL SPECIFICATIONS LICENSE B/ClOIC46#941069 DMCINTYREPAMERICANSOLARDIREr-T.COM INVERTER: MODEL NO. SE350*A-US (2400 GROUNDING DETAIL/ ROOF FLASHING P ER OPTIMIZER SPECIFICATIONS (424) 214-61040 eq CA CIO # 541065 7 EXISTING 200A ELECTRICAL SERVICE PANEL 13 % CONTRACTOR: A "r-Agi,+AMPS M*C V AMERICAN SOLAR DIRECT, INC. USE OF: EUILDING:SINGLE FAMILY DWELLING vr- CORPORATE OFFICE (N) IeOA PHOTOVOLTAIC LOAD CENTER 1-4 (D;i\\-V ) I 1116(o WILSHIRE 5LVD., STE. 500 (1) 50LAR EDGE POWER OPTIMIZER PER MODULE 0\ LOS ANGELES, CA 900.25 (SINGLE PHASE) MODEL NO. L-)P25e-LV RO PH: (424) 214-61ee i FX; (424) 214-615e WORK INCLUDES THE INSTALLATION OF UL LISTED DC City Reviaon/lPiva I Dote PROJECT ENGINEER: RATED GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM ATat I THE ADDRESS LISTED AEOVE. C'SM SHAAHIN JAHANGARD MG PE 211 N. SUNSET AVENUE THE INSTALLATION CONSISTSROOFTOP SOLAR MEPI�M�DIRE�NC.THIS 44 .'�H.VSEDIN'W. ARRAY, INVERTER(S) REQUIRED TO SUPPORT THE D�NGM�F EH�MDI$ INDUSTRY, CA 511 -10\1115A �HMMDEWM� Y PH: 626-435-9211 INSTALLED ED DC SYSTEM WATTAGE, AND RELATED mts - C vjl� a j�k �\%m' MERIWWI-PRDIIREaINC.N0 ELECTRICAL, METERING, AND OTHER SAFETY PMT�THI-�WNTISMBP FAX 626-333-e4403 Ltcl DIS..I.INHERS. EQUIPMENT, ALL EQUIPMENT WILL BE INSTALLED AS �001N OF ALW THEPMM�P�,SMDH Wj . . orm�S�DIRE�IHC, NEAREST HOSPITAL REQUIRED 5Y APPUCA5L5 CODES AND THE LOCAL <'?; \1111 DID R"Isi.ne UTILITY COMPANY. 'K, JEC-CAF/4.22.14 MENIFEE VALLEY EY MEDICAL CENTER St v \o\\ �0 HPtPSM4/28tl4 254ee MCCALL BOULEVARD DURING DAYLIGHT HOURS, THIS PHOTOVOLTAIC SYSTEM PERRIS VALLEY,EY, CA e2555 (SOLAR ELECTRIC)WILL PRODUCE ELECTRICITY IN PH: (e51) 619-6588 PARALLEL EL WITH THE LOCAL UTILITY SERVICE PROVIDER. NTS sheet -baq� T (E) REAR YARD 36-II"TO '/k PROPE LINE American Solar Direct PROUEO DEVELOPER: AMBNean SDIRr Dlre Inc. PROPOSED SOLAR 7�T LICENSE B/C70/C46#941069 PANEL SYSTEM (E) BALCONY awlDA EwGH 90 AR DIPEC Ixc. 11166 WILSHIRE BLVD,SURE 500 PLACEMENT PH:(424)21 Los ANGEIES,Dfi MD25 FX N� )21WNY"7WW D E': M�/Mmw ®ktlulle0.¢m P (02-STORY ® I Z HOUSE W 2 Z ti (n W N (nof M ® m U U 09 ® ® W w (n N m M A A E: ° a W � W � ml I Q Z J � Z � INV O 0) W Lo DG (n m a2 � PROJECT NUMBER INY OP-00149111 DG MEM SIZE: PY 9.50KW PV NE TTRLE: CUSTOMER APPROVAU VD SITE PLAN IEF EIECIwCIFN DANNY McINTYRE FEE oxuumxFquawvxeuuw FECf mx (424) 214-6700 Signadre-Danny McIntyre LICENSE B/C70/C46 N941069 LEGEND INV INVERTER WITH INTEGRATED (E) FRONT DC DC, DISCONNECT (E)DRIVEWAY YARD Q PV PHOTOVOLTAIC LOAD CENTER cilr ReriBIDR/I,BBe Dma T54-2X-FRONT R—P OP� PV GENERATION METER _ PV SYSTEM DISCONNECT AM ftNG 3WN 1DENll mnD0 PVD ONp M EUSEDINM XxUB: T�R1e4 8 -- UTILITY OPERATION °HLw"x„1O„az DFwGNAIIEn B`T°N awEwux sDLXR a RE4T Ixc.xD —}� �- — MAIN PANEL ESOARD o �ml:OVER WTHdR `HE pawn WPRIFN PERMI99pX CUSTOMER HEREBY AGREES THAT THE ASD SYSTEM WILL BE INSTALLED ON THE SIDE(S)OF THE PREMISES REFLECTED HEREIN (SEE APPROXIMATE PANEL LAYOUT ABOVE) FINAL LAYOUT OF DF euERcw soLen DMEcrmD CAO Rwisiom INDIVIDUAL PANELS MAY VARY DEPENDING UPON OBSTRUCTIONS DISCOVERED, ROOF CONDITIONS, LOCAL UNCWDING ANY HOA), COUNTY AND STATE LAWS, REGULATIONS, RULES AND CODES. JEC-CAF/4z2.14 HP/PS/04RBN4 CUSTOMER NAME CUSTOMER NAME APPROXIMATE PROPERTY ]BOUNDARY - (PRINT) (PRINT) SEE SHEET PV.I FOR ROOF PLAN LAYOUT — CUSTOMER SIGNATURE: CUSTOMER SIGNATURE 222 - e` 6 GA 0 1 2 3 4 5 6 1 s 9 10 GENERAL NOTES a American 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE Solar Direct LEGEND PROJECT 2, DESIGN COMPLIES WITH THE 2013 EDITION OF THE GRC,AND 2011 NEC, AND ALL LOCAL ORDINANCES American Solariea Inc. A JB JUNCTION BOX AND POLICIES. o LICENSE C�Ro#941069 11106 WILSNIRE BLVD.,SURE END 3. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CDC SECTION 1609 TO WITHSTAND A Los ANGELESCAei]025 INV PH:N2e121� 00 INVERTER WITH INTEGRATED DC DISCONNECT MINIMUM 110 MPH WIND LOAD. Ex.N2omsa2� aeam DG N 4. THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND B�e.mroi ..va.aa PV PHOTOVOLTAIC LOAD I THE UTILITY IS OBTAINED. B CENTER 5. THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. Z UJ 101 PV GENERATION METER 6. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS 'J THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL COPPER GROUNDING ELECTRODE (..) Ud PV SYSTEM DISCONNECT UTILITY OPERATION Z MAIN PANEL BOARD FIRE CLEARANCE T. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE W J 3'-O" MIN. SPACING MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. F- (n C IL FROM TOP OF RIDGE It-# INVERTER-STRING 8. REFER TO SHEET E.3 FOR SIGNAGE "CAUTION: SOLAR CIRCUIT' STICKER TO BE INSTALLED EVERY I0 } IZ' AND GABLE. I'-6" MIN. (1) w v FEET, AND I FOOT WITHIN TURNS, OR 5e DEGREE BENDS OF CONDUIT. 0 000 SPACING FROM HIP (E) BALCONY PLUMBING VENT, 4" AND VALLEY. It W (n N DISTANCE TO S. ALL CONDUIT TO RUN ON THE EXTERIOR OF THE HOUSE(NO CONDUIT TO BE INSTALLED IN ATTIC 0 MIN. M SOLAR PANEL P o SPACE). U fn D - e FL -----, ---- Rrz=cuz 10. SOLAR PANELS SHALL BE INSTALLED WITH NO PORTION MORE THAN 18 INCHES ABOVE THE ROOF _J Q' W U SOLAR MODULES, IMMEDIATELY BELOW. ILL! W �D SEE SHEET PV-2 FOR T U' ~ LL STRUCTURAL INFORMATION 11. THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS OR SOLAR VOLTAIC ROLL ROOFING MATERIAL Q Z co — 00 — SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING J J � Z `- FOR CONNECTION TO LLJ ROOF-COVERING MATERIAL O m (n .Ln STRUCTURE SEE DETAIL PL E � I_Z " i i 11. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE PRNELTNUMBER v. Iq BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC OP-00149111 SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. vsreM BUT: e 13. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANEL 9.50KW PV w ® SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULES)OR PANELS)SECURED BY HEM(r!_E: REMOVABLE FASTENERS. F AZ 210°w ® AZ 90°E ROOF PLAN 14. ONE- AND TWO-FAMILY DWELLINGS, LIVE PARTS IN Pv SOURCE CIRCUITS AND PV OUTPUT CIRCUITS `� OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE 1-I �� ENERGIZED. HiEF ELECTiaC1AN 23' SLOPE ' 23' SLOPE DANNY McINTYRE ' SermusaewoauounswEcr 15. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE D LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. (424) 214-6700 (� NV JB ,' ,' ' l7 signature-Danny MCI"I , e , �� 16. 'CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED" LABEL SHALL BE LOCATED ON MAIN SERVICE LICENSE 81C18/C48 M941089 DG ¢i PANEL PV CONDUIT - y EXTERIOR INV 11. SMOKE DETECTORS AND CARBON MONOXIDE ARE REQUIRED PER 20I3 CRC, CBC, CFC. (PAINTED TO MATCH DC `\ 18. ALL MARKINGS/WARNING LABELS SHALL BE VERBATIM SPECIFIED IN THE MORENO VALLEY FIRE �P EXISTING COLOR) DEPARTMENT PHOTOVOLTAIC GUIDELINE (CFC610.1 AS AMENDED AND OUTLINED IN THE MV nRE an ___ y, H PV I -1 DEPARTMENT � PHOTOVOLTAIC GUIDE PAGES 2-5. ALL SIGNS SHALL BE REFLECTIVE. THE PLANS SHALL PROVIDE r DETAILS FOR EACH OF THE REQUIRED MARKINGS/WARNING LABELS, INCLUDING VERBIAGE, FONT, SIZE, gq HOUSE REFLECTIVITY, AND MEDIUM. THE GUIDE CAN BE FOUND AT: �. 1-1 litl HTTP://WWW.MORENo-VALLEY,CA.US/CITY,HALL/DEPARTMENTS/FIRE/PDFS/GUIDEUNES/ V gI PHOTOVOLTAC2011.PDF Cit ftevieian/Issue Date XISTING F ABBREVIATIONS 11 p FILE ROOF�T I AZ AZIMUTH a PROJECT BREAKDOWN (E) EXISTING (E) 200A SYSTEM SIZE: 9.50KW SYSTEM (35) RENESOLA JC25OM-24/55 SOLAR MODULES TMls ox mxGevnDEEa of AMENCW EDLMDIP£Llwc.TH. CLR. CLEARANCE ELEGTRIGA IN (1) STRING OF 10 MODULES 6 IN (1) STRING OF II MODULES ON (1) SOLAREDGE INVERTER OPAfflMISCONROENn ANDM SERVICE ONLYro9E USED INCONJUCFON MIN. MINIMUM F� VVF Si wEBC nBODEscruhDDv j�e A DIMENSIONS AND MODEL SE5000A—US (240V) MEwEw I DOCUMEDTINc.NPANTBE PV. PHOTOVOLTAIC AZ: 1SO's STRUCTURAL INFORMATION IN (1) STRING OF 11 MODULES ON (1) SOLAREDGE INVERTER MODEL: SE3500A—US (240V) IE.a3 ..„. EFD`rwN O ROG. RIDGE OF PMERMN 8DIAR DIED!&C FOUND ON PV.2 M R.W.re VLY. VALLEY HOUSE HEIGHTS 2-STORIES J Gv. GAS VENT® TRUSS SPACING: 2 X 4 0 24" O.G. JEC-CAF/4.22.14 PL PLUMBING VENT Q 23° SLOPE ROOF MATERIAL.' FLAT TILE HP/PS/0428/14 AV. AIR VENT ® RACKING SYSTEM: SNAP N RACK ROOF AREA: 2916.41 $0. FT SM t ROOF PLAN SCALE= 3/32" = 1'-0' TOTAL AREA COVERED BY PHOTOVOLTAIC ARRAY-' 23 % Pvi A American Solar Direct PR°4E47f DEVELOPFA: American Solar Direct Inc. LICENSE S/C10/C4611941069 owl(E) BALCONY o u.4:wuM sous m w:cr nc. KW..WnW � L trim WLLBHIgEosAHDE�.Gaeo� we Nz,7z,aswo EM:�py NWE6:lYe/Mvx•nglymgMUYvtmn PLo FIRE LLR - FIRE cut o L W I1-S2 j 12-51Gv I J W 7y U Z QI U I2-s1 W J Ir ~ CO 11-S2 12-S1 }o � PIL "4'-" U� W Q 0' U Z 2 � Ii Iz-s R LU U � w - U W � Q (p I7-52 ® 12-51 W W d' U � ,U �Y W W W to co tl-S2 GY ® ® < U' W LWL J J Go Z / QJ � W � °PL 12-57 m 04 v� / / v . v PRaecr HUMa6rt 11—S2 ,' \� \` 12—S7 PL OP-00149111 o-L \ Y6TEM 61IE: 9.50KW PV SYSTEM INV JB '/ ',' /'.. �; 12-S1 D LAYOUT DC PL W- ,, 1F W. HIEPELEDDU DANNY MDINTYRE i , , / I aMv�,rtza.MF6mMeanwwEawx INV / / ` Iz-s, (424) 214-6700 DC Signature-Danny McInW '- LICENSE S/C70/C46#941069 PV FIRECLR. ----- �Q y,� (E)2—STORY M ; ,v q HOUSE 0� PVD �i 11-s1 is LEGEND M ®cY = GAS VENT �• OPL = PLUMBING VENT PIPE city Re amn/laeae 0a. I i AY = AIR VENT II-SI Hn nvwwDn aDP eITC nMEwux saur dvEm nc.rHe myM Ee°enDEemcMIDD aurroae usmnc°wixarn �C vmmw°xn°Esicr m., STRING NO. ua:wuxswRaw:awc.x° vwry m�s D°aMamwmac INVERTER NO. Dan°smromxew,wln+Dur mcvwatwwnw vawasnox oc wEwuaswa°wccrnc. ROOF ACCESS CAC RA JEC-CF14.na F/4.22.14 HP/PS/04R8114 FIRE CLEARANCE Sheet SYSTEM LAYOUT SCALE= 1/0" = I'—&" PVI.I ROOF pRUSS24' OC i CONNECTION DETAIL 0.06 rican SOLAR PANEL SECURING CLIPS 5/I6'X 2.15`B.B.BOLT R Solar Direct SNAP N RACKS 6/16'B.B.SPOT LOCK WASHER PROJECT OEVELOPER: SOLAR PANEL SYSTEM MOUNTING "btNLAPVN SNAP N RACK SERIES ISO RAIL AENSE B SolaCIO/Direct Inc. LICENSE B/CTOMAB#&11089 B G1RI G C SYSTEM SNAP N7��7 I )E9WILSHR &M.5 nESM = RACK. END CLA SNAP N RACK CNAMEL NIT Los MGELEB,twvoms F Pv MOUNTING SYSTEM SNAP N RACK RIHBER RAM EM H24)21 Iw n� SNAP N RACK WEB:Md1"-x•amMM•mWY,emm� POINT OF COJNECfldJ COLLAR INSTALLS TOP of FLABHNG AT ROOF TRUSS TO BE 4'-B`MAX STAND OFF CLAMP FLAVVBNG 5/16"X]'B.S.BOLT t B I/T`MAX BPAGNG POINT OF CONMECflgJ 5/I6`B.B.SPLIT WASHER 5/16'X I'B.S.BOLTG 5/16'B.B.SPLIT WASHER Z ROOF TRUSS AT ROOF TRUSS TO BE 4-0"MAX SNAP N RACK STANDOFF INSTALLED FROM BACKSIDE OF STANDOFF LLI T X 4 R 24"O.C. SHAFT BTD(VARI019 OYES) BABE PRIOR TO MBTALLATDN J LANDSCAPE PANEL(NTS) PORTRAIT PANEL(NTS) V U.l 5/16'8.5 LAG SCREW WITH FLAT WASHER BEAL PENETRATION AND WIDER BASE W ].6'MNIiJM EMBEDMENT ISBTANIDARD WITH APPROPRIATE ROOF SEALANT. POINT OF CONNECTION DETAIL SCALE = NTS F- w 42'-6., _ �€ MOUNTING SYSTEM SPECIFICATIONS a) w o � MANUFACTURER: SNAPNRACK Pv MOUNTING SOLUTIONS U Z = 04 Lij 115 FIERO LN, SUITE 200. SAN LUIS OBISPO CA.S3401 F- 0 6 W BALCONY 6-a" N MODEL •511•132.2660 EMAIL: TECHASNAPNRACK.COM W U) Qto - - SERIES 100 RESIDENTIAL MOUNTING SOLUTION I j W W_ W (gyp MATERIALS: w 0 F- � 6000 SERIES ALUM., • STAINLESS STEEL, GALVANIZED STEEL < Co Z i � Co U- CALCS +CRTIFICATIONS: O LU Lp I _ NM *ASCE 1-10 WIND SPEEDS FROM 110 MPH TO ISO FOR B AND C EXPOSURE CAT. V o +ASCE 1-10 SEISMIC DESIGN CATEGORY E PRO EC NUMBEw i I x a� x i ASCE 1-10 SNOW LOADS UP TO 120 PSF GROUND SNOW LOAD OP-00149111 ie *BUILDING WITH MEAN ROOF HEIGHTS UP TO 60 FOOT TILT ANGLES/ROOF PITCHES FROM 0 DEGREES TO 60 DEGREES, 9.50KW PV 1 ®I iB" I i GRCVND/Ms+ NEETTrrU LAYOUT + 42' ' ® *STAR WASHER CONNECTION \ I *ELECTRICAL EQUIPMENT BOND STAINLESS STEEL LAY-IN LUGS (G5L-4DBT UL DETAIL - f,' ' °•` �\ 151'-I° FILE E34440) ID'ELECTRIGM �i \, "�° �' � i APPROVED STANDOFFS TO BE MOUNTED AT INTERVALS TO PROVIDE DANNY McINTYRE ADEQUATE SUPPORT FOR MODULES FROM ALL ENDPOINTS. STANDOFFS WILL (424) 214-6700 BE SELECTED BASED ON ROOF LAYERS PRESENTED. slgnBWre-oBRny MNRryre MODULES SHALL BE INSTALLED WITH A MINIMUM 3 INCH CLEARANCE FROM LICENSE S/C70C4U#Bo7aw w I ROOF SURFACE TO PANEL g= �- STANDOFFS SHOULD BE PLACED AT EVERY ROOF TRUSS AT 4'-0" MAX l 2X4 TRUSS /(02-STORY SPACING. TYR 24'. QC pTOTAL# OF PANELS 36E.O.RUSE \ I AREA COVERED(50. FT.) bbb.52 �• ! AVG. LOAD PER CONNECTION POINT (LBS) 25.43 CRY RaPlelon/lvvuv Ovle WEIGHT PER 6Q. FT. OF SOLAR ARRAY(P6F) 2.98 Q��f�Css � w TOTAL WEIGHT OF MODULES 1638.18 �o I, H( ------- E TOTAL WEIGHT OF RACKING COMPONENTS 353.68 Co ixlsoxnwwoevaoavTrcv NQ' ti� TOTAL SYSTEM WEIGHT (LB5) 19B3.88 I W d ONLY TO ei UGONFSED iN OONJO mgM 1:_2. 6-4.: TOTAL RAIL LENGTH (FT) 258.13 p ucwsow°1WIwc °ixcTra c PutTOPTxlsooaMExr lsrovE I f f { # OF IB"SNAP N RACK RAILS (122") .=WE°rooTMER9BTMWT 11 TMEPMwa�PEnvnsswx # OF 13 SNAP N RACK RAILS (102") or MaETocav souxoMEcrxc. 19 13,_3" 16•_4„ •- 16 �'P,� �iV{L \� CPD Revivione -- 42-6 TOTAL RAIL LENGTH FIELD (FT) 266.83 o@` # OF SNAP N RACK RAIL SPLJGES II OF C�l`� HP/PB/0428/744 NOTE: PLEASE REFER TO SNAP-N-RACK MANUAL FOR INSTALLATION REQUIREMENTS. TOTAL# OF END-CLAMPS 40 2� /y TOTAL# OF MID-CLAMPS 56 Sheet LAYOUT SCALE= NITS I I TOTAL# OF STANDOFF A55EMBLIES IT8 PV2 TADLE A DC STRNG C4MIOURA7ION ow NorE EXPOBm C INDUCTORA WALL EOUTDOORORS FOR ',MODULE American CONDUCTOR CONDUCTOR LOCATION NUMBER IN SHORT CIRCUITCURRENT VOLTAGE ( CONDUCTOR CONDUCTOR CTYPE FACTOR A7 65-CC 050•F) THWN-]TUBE-2 SUNLIGHT RESISTANT. I INTERCONNECTION.DO NOT REMOVER THE OWLS K]CON CONNECTS,OTHERWISE THE MODULE WRATED� TARRANTY AND THE UL US71NG SOURCE CIRCUITS MODULES M 18G FT. VOLTAGE(DC) SIZE TYPE OSolar Direct � SERIES B OPT. IMPP W AT OPTIMIZER (.4.UIt"i) TYPE (E,.IT) PER NEC 918.15�)U)(W EXPOSED CONDUCTORS SHALL E WILL BE INVALIDATED. PROJECT DEVELOPER •INV. b FASTENED TO MODULE FRAMES OR 66 AWG BARE COPPER GROUND BILL E USED AS AN EQUPM MINT GROUND FOR THE MOD"FRAMES.USE American Solar Dllect Ire. I.1 MODULE TO JUNCTION BOX 10 8.83 A 15.5 A 350V IB URE)UBEh N/A (010 AT 150.140A Xb843.2A RACKING FOR PROTECTION(SUPPORT. MODULE GROUNDING METHODS PER THE MANUFACTURERS INSTALLATION REQUIREMENTS.THE MODULE LICENSE B/C7(I/C48#9410E9 ALL CONDUIT TOE 7 112'OFF THE ROOF. ]U EQUIPMENT GROUND SHALL GROUND ALL OTHER EQUIPMENT AND SHALL TERMINATE IN THE INVERTER om1cAlEwcarl soon ollEcr Nc. 1D ,7UNICTION BOX TO INVERTER I0 8.89 A 15.5 A 350v I0 THIUNJ-2 914' (410 AT 160•k0A XFNY]3.14 PER NEC 910.16(BX,XC) CABINET.NOTE;GROUNDING LUGS USED FOR GROUNDING;BEE GROUNDING DETAILS FOR SPECIFICATIONS. t1T30vnLsxREazw..sunEsoU 1.3 MODULE TO JUNCTION BOX II 8.89 A 15.9 A 350V IB URE)USE-2 NIA (•IB AT 150•40A X5B=79AA cos u+OEiEe,Geoszs MIA 3R JUNCTION BOX USE WEATHERPROOF STRAIN RELIEF TO BRING(PV WIRE)USE-]ITHWN-2 SOURCE CIRCUIT PR(424)2t4 1.4 JUNCTION BOX TO INVERTER 11 B.B3 A IS.S A 350V I0 THWN-T 314' (410 AT 150')40A XbOV3.2A O CONDUCTORS INTO THE JUNCTION BOX TRANSITION TO THHN I THWIYI CONDUCTORS IN JUNCTION BOX USE TO FX(424)214 9) PULL OUTPUT CIRCUIT CONDUCTORS TO BOLAREDGE INVERTERS SE5000A-M(740V)4 SES900A-US(24OV) EM:a•. ram 21 MODULE TO JUNCTION BOX M e.83 A IS A 350V 10 LIRE)WE-] WA (a10 AT 150•M0A X5B=]9.7A wEa;N•vMxwa�l®,.dmelaeaan SOLAREDGE INVERTER B NEMA 9R RATED WITH UL IT41 LISTING INCLUDING INTERNAL ANTI-IBLANJING 2.2 JUNCTION BOX TO INVERTER M B.B3 A 19 A 56BV 10 THW" 9/4' (f10 AT 150•kBA XBe &2A PROTECTION FEATURES,LIJ141 LISTING INCLUDES COMPLIANCE WITH IEEMUS FOR POWER QUAUTT,IEMWII TADUN Q AG CONDUCTOR AND CON=IDIONTFIICATM O FOR INTERCONNECTION SAFETY AND THE NATIONAL ELECTRIC CODE TIED To EkiSTING FACILITY GROUND. AMPACITY CONDUCTOR CURRENT CARRYINGS; NEUTRAL EQUIPMENT GROIIDEIG GROUNDING ELECTRODE INVERTER HAS INTERNAL DC DISCONNECTION MEANS.INVERTER IS LLL LISTED AS A WT.UNIT 15 EQUIPPED Z GQIDIlGT� VOLTAGE NUMBER OFCONDUCTOR LOCATION (VOLTS AC) PHASES WITH X 1.75E CONDUCTORS TYPE CONDUCTOR SIZE WIRE CONCUCTOR CONDUCTOR GONDW BATH LLI141 APPROVED GROUND FAULT DETECTION DEVICE THAT MEETS NEC]50.122 REOUIREMENTS FOR (AMPS) 90'C (AWG) (AWG) (EGC) (GEC) (EMT) EQUIPMENT GROUNDING. NOTE SEE ATTACHED OUTSHEETS FOR DETAILS. W 5O PV LOAD CENTER TO TO BE PLACE BETWEEN INVERTERS MAIN PANEL BOARD SEE SINGLE O INVERTER TO PV LOAD CENTER 74B IPH UP) ]b.]B A ],N,GND THNM-] Fl0 010 f8 fb 3/4` LIE DIAGRAM FOR AMPERAGE RATING AND MANUFACTURERS SPECIFICATIONS Vcc LU O INVERTER TO PV LOAD(.ENTER 740 IPH UP) JB A 2,N,GND THWN9 i10 NN0 i8 06 3/4' O PV GENERATION METER_TO BE PLACED BETWEEN PHOTOVOLTAIC LOAD CENTER TO PV DISCONNECT C g 3s W O Pv LOAD CENTER TO MAIN PANS BOARD 740 IPH UP) 4e.25 A 71 µ GND THBIN-] f6 ib r6 i6 I` METER SOCKET MODS.COOPER B-LINE 011 '^ LI.I PV SYSTEM DISCONNECT UTILITY OPERATIONS -TO BE PLACED BETWEEN INVERTER AC OIIPUT AMID V! TEMPERATURE INFORMATION lO CONNECTION TO UTILITY TO COMPLY WITH NEC 690.61 AND I AEC 93.0201 TO BE VISIBLE OPEN BLADE, LOCKABLE TYPE DISCONNECT LISTED FOR ITS USE >- X 99•C-10]'F- ASSUMED WGHEBT TEMPERATURE - (n (I.I JC]60M-]4/BB SOLAR MODULES HIGH TEMPERATURE CORRECTION LOW TEMPERATURE CORRECTION SOLAR EDGE POUTER OPTIMIZER 50-LV RATED DC INPUT POWER-260 WATTS,INPUT VOLTAGE RANGE 0 000 -l' M ]0°TU ASSUMED RATED TEMPERATURE gO -5 TO 55 VDC,MAXIMUM INPUT CURRENT-10 ADC,MAMMUM LVtPUT CURRENT-IB ADC,STRING V Z = In ELECTRIC UNITS TEMPERATURE RATED TEST TEMPERATURE HIGH CHANGE CORBEL CORBEL CORRECTED LOW CHANGE CORBEL CORRECTION C LIMITATIONS-B TO 25 OPTIMIZERS 5250 WATTS STC PER STRING MAMMUM (E250W/16 ADC=3b0 VDC) ICI U) (N DATA COEFFICIENT OUTPUT TEMPERATURE TEMP. IN TEMP. (E) (INDICATED OUTPUT TEMP. IN TEMP. (E) (INDICATED OUTPUT G1RR IS C.,UP 1 CCORDANGE H TIC 690.b IS TO 1.] SG E Q O) MIND) (a STC TEMP) CC) (•C) ('C) UNITS) C.TS) ('C) (•C) UNTO) 1.25-8.83=11.04 AD THE POWER OPTIMIZERS INCLUDE AN INTERNAL CURRENT LIMITING FUNCTION AND HAVE O CONTINUOUS OPERATION THE MAMMUM SUGGESTED MODULE IBC IS THEREFORE 10 V (n I:h PWIERUisPwrmP•Irtm) WATTS -0.4 7719 78 99 14 -8.6 -I].l4 114.T6 -1 -92 17.8 22.6 750 BEEN EVALUATED FOR B AMPS.USE OF HIGHER CURRENT MODULES WILL NOT DAMAGE THE POWER OPTIMIZER BUT CO.x D RESULT IN LLI W W U ��• REDUCED ENERGY YIELD DUE TO Cl1RRENT LIMITING.(PER MANUFACTURERS INSTALLATION b90.1(A)) OPEN CIRCUIT VOLTAGE(V.) VOLTS -0.30E 514 25 !9 14 -4.2% -0.586 35.83 -1 -97 9688 0.056 40.99 r PLEASE NOTE'•SYSTEM VOLTAGE ADJUSTMENT FOR LISTED MODULES AND DEVICE ARE MADE IN tLI W Lu (Q A DANc WITH T MANUFACTURERS INSTRUCTIONS S � F- W -tT SHORT GROUT CURRENT(I.J AMPS -8.04 OLDS M 99 14 -0.% -0.049448 B.eB -1 -32 1.28 1.28 6.8E THIS SCHEMATIC ONLY DEPICTS THE FLOW OF POSER O2 WORK FROM THE PHOTOVOLTAIC SYSTEMQ 0 00 UL r IT ALSO DEMONSTRATES THE INTERCONNECTION TO THE UTILITY GRID.INSTALLATION METHODS _ AN DIOR LOCATION OF EQUIPMENT MAY VARY DEPENDING ON FIELD CONDITIONS AND VARIATIONS. O J ( W In 10-250 WATT PV MODULES RENEeCLA C(INTERIC IDGE SE5000A241 INVERTER . m NM � TED DEC EFFICIENCY•T40 VAC INVERTER I-STRING I SOLAR I'IOOW-EB I 00 WAC CONTINJOUS PROJECT NUMBERVOC MODEL:JW60n-,4/BB M MAX AC POWER ORPUiOP-00149111 TPUT LB�NTD-FA tuL PROfEGt1OiIPR VIIDmR NEC ARTICLE&Son FOR NEC,OIFI690PRCOMPU�NICEEXISTING WAIN HOE PANEL120D420 I d9 WIRE SERVICE9.50KW PV NEMA 9R DCEDGE DUAL SAFETY BUNTCH A WAIN 700A BUS BAR RATING ENCLOSURE VAC,92 AMPS CONTHIJOUS1 C 1 'L -- -- ---- ---- -- - IALL VVCU3]UNGARwNIDEGOD"RNUOUS G TORE W)100A PV GENERATION wiSIJtt OP STEM FATIS"ON4`T DISTRIBUTIONMAIN UTILITY MIIETERMGSINGLE (JN� + j ___-__ NEC ARTICLE 690.35 PV LOAD CENTER C METER C SECTION BREAKER BFDTOJ N 30A O 60A wao� Il5A O TTOLfR DIAGRAM MAIN OANNY McINTYRE I II U 13 • • • ]B ,I 1.1 1.] I r_____ mB1�R I I TB A WITH PLACARD -�'w� omNtrwrxveaurmxEacaJ • L9 1.4 , ---- ----- ----1 P EXISTING MAIN (424) 214-6700 I 240Y IPH,2P I BREAKER ---• • • I 740V IPR2P NON FUSED I SOA °PV TO BE B 4099410 I I naUle-Dann • - - • - • - s NO, HO.161]u00RB SQUARED 1 I DE-RATED LICENSE BIC7SC46 B947088 I COOPER 13-UE I MODEL DW22 RBI L------------- I FROM 200A II-260 WATT W HL9UFJ1 MODEL;at I I ---_ ______ r _________ ______J___________ 2 INVERTERI-STRNG2 8 HOFFMAN f___--_ GEG __ _ l__ I MODEL AbRb4(bXbX4) n EF IC! Y 024 INVERTER IT-760 WATT PV MODULES 9B8 CEG EFRGEENNGGT R]40 YAG I I CONPAJOUSN INVERTER]-BTR I I 0 41W MAXX AC P OUTPUT I NIG A` I t M UV CZITpUT CIURfENlT 16AMP8 I I I O I GR NBC ARTICLE E6W.31 PROVIDED I �� SYSTEM GROUNDING j I z 3 • • • 16 IT N8M4 9R 1NTFRCa�RA `tED AA RG'FAI LtOF'ROTEcnON I II (TYPE U FOR NEC 1011 690.11 COHPLJANCE L__ _____ (�'AWG) ____ v - E GROUNDED AT 11 11 - ° . - DC AC OC/AC SAFETY SWITCH , �r FLU,f C• N 1 EXSTNG LIFER,SERVICE p. 1 ' HOFFMANMODEL;A6064(bX&X4) I a 900 VAC.32 AMPS CONBNIOUB C1,B __ ° OPENS ALL'3]UNGROUIDED LONIDIIDTORB I CIT`1 OF OR VERIFIABLE PANEL D BULB AND/ GROUNDING ELECTRODE L____ PER NEC 4RTIGLE 690.38 I �� AF,(p 5 R� CB Re4abn/Inue D•fe n III, pVA - - I T I NET ENERGY METERING(MENU)INFOR D IR It I L2 I • L maoRnvmcle vlmFRRrroF I I PANEL INVERTER NUMBER PTL RATING INVERTER AC !7 oRnRUxauwx gFnERiitQuuaHp® u I MODEL MODEL OF (WATTS) EFFICIENCY NAMEPLATE �( CIRCUT gxLrro YEuamlx conwcTlDx I N I PANELS (E) WATTAGE pl'•®BEAKER T'amwwgolacwuFn er EGC I rw-o R AID,RATING- _________________J III 6OAREmE v58 • 40I 66M-241M 6E6000Av 21 271.9 PaA.E1TROMFA'MNm•g1I1RWgAREEmCr1g8roFtqeE MAIN 9ERV1 E BUS RATING PER oBrxoamroomEFbmmour SYSTEM L4BEL9 U40V) of M.,CNI�xq�of q�qi R�iC. MAXMUM DC VCLTt -506 VOC 60wREDGE e(mltl "N .64, 105.12(DX2) NOMINAL OPERATING VOLTAGE•960 VOC , 6B� 6E INVoA UB Il 221.9 9B 3196.81 X 120%- 240A CAD N•ri3ioni all not he coll"I"d to h aeml sWJPGG N E LAUD 132A JEC-CAF/422.14 NA TOTALM1 1�Lf*r'4 o t BQ n f anY p(ovisions pf the fe be v�p�1; 4f6.25A HPIPSIO4 2E 14 014 p(oved plansi l 1 Bus LOAD- 118.25A S 240A _ Snee( SINGLE LINE DIAGRAM AND CALCULATIONS - 5.50KW SYSTEM - (35) RENESOLA JC250M-24IBt3 MODULES 1 (2) SOLAREDGE I L90*P(§�(660A-US (240V) f SE3500A-US (240V) NTB E2 �obsite until comp Electrical Load Calculations Electrical Load Calculations dAmerican S018I DRaCt Residence Residence FR EG DEVELOPER: Amerim Soler Dimt Inc. Address: Sq.Footage of House: 3,269 Address: Sq.Footage of House: 3,269 LICENSE BIC10/C464941069 mm,ue:wrwx a ova wREcr Nc. Calculations Prepared By: Raffi Dersarkissian DATE:4/14/14 Calculations Prepared By: Raffi Dersarkisslan DATE:4/14/14 'rwwa sw�wls �w k HFq 21 eW M vwffsny.e.rr,w.�,mx IipJMw:a bNMimn VOLT AMPS OR OPERATING LOAD ITEM QUANTITYX WATTS TOTAL LOAD ITEM QUANTITY X CURRENT TOTAL H (AMPS) Z A.General Load Circuits W B.Full Load Circuits J General Lightning Circuits 3269 sq.ft 3/11:2 9807 Mechanical Circuits: V W Small Appliance Circuits(2 minimum) 2 X 1500 3000 Air Conditioner or Electrical Heater* 1 X 25 5750 W Z Laundry Circuits 1 X 1500 1500 Air Conditioner or Electrical Heater* 1 X 19.9 4577 fA Electric Dryer 0 X 5000 0 Air Conditioner or Electrical Heater* 0 X 0 0 W- Fixed Appliance Circuits Electrical Heater or Furnace* 0 X 0 0 U) V O NT Electric Range 1 X 8000 8000 Pool Equipment: IX W X N Electric Counter Cooking Unit 0 X 8500 0 Pump Motor(Filter)** 0 X 0 0 H 0 M Electric Oven 1 X 8000 8000 Pump Motor(Booster)** 0 X 0 0 - W W (¢,) Refrigerator 2 X 1200 2400 Pump Motor(Other)** 0 X 0 0 W U W W Built-In Microwave 1 X 1600 16001 Pool/Spa Aerator** 0 X 0 0 of 0 ~ W It 00 LL Dishwasher 1 X 1200 1200 Pool Sweep** 0 X 2.5 0 1 J C['O Z Garbage Disposal 1 X 1000 1000 - 0 0 _3 to W Lo G7 m N � � Trash Compactor 0 X 1200 0 Electrical Vehicle Charger:per 2014 NEC 625.14 P EU NUMBER Furnace 2 X 550 1100 EVcharger 0 X 0 0 OP-00149111 Electric Water Heater 0 X 5000 0 Total Full-Load Equipment Circuits 10327 YeiE4A e9E: Central Vacuum 0 X 1800 0 C.Electrical Load Calculations 9.50KW PV Whole House/Attic Fan 0 X 1600 0 Total,Section B(Full-Load Equipment Circuit)-Amps A46.25 "�T Vent Fan 0 X 240 0 Total-Watts LOAD Garage Door Opener 1 X 800 800 Total House Load-Amps(Total Watts Divided 240 volts) CALCULATIONS Pool Light 0 X 250 0 Total PV Load-Amps HIU EIE(Mtl WHot Tub(Spa) 0 X 8500 0 Total combined Load(house+PV)-Amps DANNV MdNTYRE oe0 Size of Existing Electrical Service-Amps*** - (424) 214-6700 0 Proposed Size of New Electrical Service Equipment-Amps sigmbee-Dwnr McIntin LICENSE B/C10/C984941069 Subtotal 38407 *Air Conditioner or Electrical Heater(whichever is greater) Per 2014 NEC (FLA x 240 Volts=Watts) FLA=Full-Load Amps Subtract:per 2014 NEC Article 220.82(B) -10,000 **Pump Motor,Aerator and Pool Sweep(Amps X 240 Volts=Watts).Per 2014 NEC Table 430.248 General Load Circuit 28,407 ***The Size of the Existing electrical service to be greater than the total combined load of the house and PV Total,Section A x 40%(General Load x 40%) 11,363 Full-Load Current in Amperes lOK Watts at 100%:per 2014 NEC Article 220.82(B) 10,000 Single-Phase Alternating-Current +� To Circuit 21,363 Motors:Per Table 430.248 tal General Load �. NOTES: HP 115V 230V 1)240 Volts x Amps=Watts(VA) Watts/240 Volts=Amps 1/6 4.4 2.2 Ra4ebn/leave 0ele 1/4 5.8 2.9 2)This Schedule is Based on the National Electrical Code(NEC)and is intended as guide for preparing electrical 1/3 7.2 3.6 rMsoPnvnnu*P^��R�'� calculations.However,due to various conditions that exist on individual projects.If you have any questionsuµo� regarding the use of this form,or electrical load calculations please contact the Chief Electrician at 626-435-9231 1/2 9.8 4.9 nMroegNspmx�x:Ipx 3/4 13.8 6.9 1B�nOmWWMproP Beaosmmal�Rswnmur 1 16.0 8 avmra,e"�1B'ovno 1 1/2 20.0 10.0 cen Re4sione JEC-CAF/422.14 2 24.00 12 HPIPSM4121Y14 3 34 17 Sheet LOAD CALCULATIONS 14Te2 1 COMBINER BOX/CIRGWTSI ENCLOSURES PHOTOVOLTAIC PRODUCTION/ NET METERING .�American PV SYSTEM Solar Direct PROJECT DEVELOPER: GENERATION METER AE.NSENSoler46#S4nc. WARNINGENSE B C70/C48#941059 o xD+B AMEwral sous mREcr rrvc. PER NECNEG 690.6(G) ++>exwilsniRE alw.,sulTEsoB L�MIaF1E9,GBY115 ELECTRIC SHOCK HAZARD PH:14xp114 0 WARNING "^�+� EM:wv�woy,wwm.weasm, THE DC CONDUCTORS OF WE6.MroJ .e'.wreM.E.1q ELECTRIC SHOCK THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY HAZARD BE ENERGIZED. Z IF A GROUND FAULT IS W G) INDICATED, U W 690.56(B)I690.35(F) NORMALLY GROUNDED Z PER NEC CONDUCTORS MAY BE 2 EMT/ CONDUIT RACEWAYS AT EVERY 10 FEET UNGROUNDED AND H ©� 0 �1 ENERGIZED. U) Cl) © PER NEC 690.5 (C) LLI o CAUTION: PHOTOVOLTAIC �1 PV DISCONNECT/ BREAKERIPgNTS OF CONNECTION U U O C POWER SOURCE IX o (n C t PER NEC 690.31(E)(3)Q CFCIIPC 605.11.1.2,605.11.1.4 PV DISCONNECTLU U Q n INVERTERS -i W I J PER IFC 605.11.1,IFC CAUTION: NEC 690.15 f NEC 690.14(CX4) J Z oro Z CROSS REFERENCE NUMBER WTH 81GNAGE MAIN SERVICE DISCONNECT J LU to SOLAR CIRCUIT CI (n m N 2 6A6.11.1 MARKMG. MARKING 15 REQUIRED ON INTERIOR AND EXTERIOR DIRECT-CURRENT DISCONNECT WARNING: MULTIPLE POWER SOURCES PROJECT MUMBEw (DC)CONDUIT ENCLOSURES RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, PER NEC 690.31(EX3)Q GFGIIFC 605.11.1.2,605.11.1.4 COMBINER BOXES AND DISbONNECTS UTILITY POWER @ 240/120VAC, 200 AMPS OP-00149111 665.11.1.1 MATERIALS. THE MATERIALS USED FOR MARKING SHALL BE REFLECTIVE, DC DISCONNECT ON INVERTER MAIN BREAKER TO BE DE-RATED TO 175 AMPS WSTEM SIZE: WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS 3 PV POWER @ 240VAC, 46.25 AMPS 9.50KW PV REQUIRED IN SECTIONS 605.11.1.2 THROUGH 605.11.1.4 SHALL HAVE ALL LETTERS PER NEC T05.12(DX4% NEC 650.64 NEC 690.14(CX4) CAPITALIZED WITH A MINIMUM HEIGHT OF 318 INCH (9.5 MM)WHITE ON RED DC DISCONNECT RATINGS: HEEL TrrLE: BACKGROUND. SE5000A-US OPERATING CURRENT:21 AAC CAUTION: 605.11.1.2 MARKING CONTENT. THE MARKING SHALL CONTAIN THE WORDS "WARNING: OPERATING VOLTAGE:240 V AC SIGNAGE PHOTOVOLTAIC POWER SOURCE MAXIMUM CURRENT:32 A DC SOLAR ELECTRIC SYSTEM CONNECTED 660.11.1.3 MAN SERVICE 0*C4NECT. THE MARKING SHALL BE PLACED ADJACENT TO THE MAXIMUM VOLTAGE:600 V DC CHIEF ELECTRICIAN MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE PER NEC 690.5 (C) DANNY McINTYRE LOCATION WHERE THE DISCONNECT IS OPERATED. PER IFC 690.14(CX2% IFC 605.11.1, _ 605.11.1.4, 646.11.1.4 LOCATION of r1ARKR+6. MARKING SHALL BE PLACED ON INTERIOR AND ., INVERTERS NEC NEC 690.15 4 NEC 690.53 (424) 214-6700 EXTERIOR DC CONDUIT RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 WARNING: SI9neWne-Danny McIntyre FEET (3048 MM), WITHIN I FOOT (305 MM)OF TURNS OR BENDS AND WITHIN 1 FOOT CAUTION. LICENSE BICIOIG46#941009 (305 MM)ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR PV DISCONNECT BARRIERS. SOLAR CIRCUIT BACK FED BREAKER SIGNAGEDO NOT RELOCATE CODE ARTTIICLE EQUIREMENTS 690 MARKINGS SHOULDTO CPLYTBE AS NEC A10LLOW: DISCONNECT PER NEC 905.12(DX4), NEC 690.64 NEC 690.14(CX4) • RED BACKGROUND PER NEC 690.31(EX3)f CFC/IFC 605.11.1.2,605.11.1.4 WHITE LETTERING 4 DC DISCONNECT ON INVERTER CAUTION �� +� • MIN. 3/8 POWER TO THIS BUILDING IS ALSO SUPPLIED LETTER HEIGHT DC DISCONNECT RATINGS:CURRENT:96AAC FROM THE FOLLOWING SOURCES WITH ALL CAPITALS OPERATING CURR SE DISCONNECTS LOCATED AS SHOWN. 0. • • ARIAL OR SIMILAR FONT OPERATING VOLTAGE:240 V AC City R.,—.—w/lasue OOte MAXIMUM CURRENT:32 A DC • NON-BqLD MAXIMUM VOLTAGE:600 V DC . . PER NEC 690.5 (C) WARNING (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT)REFLECTIVE WEATHER ' • PHOTOVOLTAIC AMHSu GaoieExPOEcr'E"`m RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT DMWIN36CONFI�.ANe IS PHOTOVOLTAIC LOAD CENTER SYSTEM CONNECTED ONIX TO BE USED IN croNMDTgN THE PLAQUE WILL BE ATTACHED BY POP-RIVETS, SCREWS AND/OR OTHER APPROVED '' _ � O6q��BW MAIN DISCONNECT HAS BEEN AMEwO....PEAT IDBY PART OF THIS Dona n,T e ro BE NcW FASTENERS. (GEC 90.T, 110.3) DERATEDTO 175A OsaossDTOOtxB•s vnmaR TIE PwQi wBmEx PERMLssION ALL FEED AND PENETRATION TO BE FLASHED AND WATER PROOFED NOTICE DO NOT ADD LOADS TO THIS OFAMBBE:ATI•owtowECT•uc. MARKINGS WILL PROVIDED IN ACCORDANCE WITH THE GAL-FIRE SOLAR PHOTOVOLTAIC PV SYSTEM COMBINER PANEL ELECTRICAL PANEL CAD RwWone JECCAF/4. INSTALLATION GUIDELINE. DO NOT ADD LOADS TO THIS PANEL SERVICE POINT: SOLAR CONTACT: HP/P5/0428114H4 -UTILITY METER-MAIN PHOTOVOLTAIC AMERICAN SOLAR DIRECT MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. IT IS RECOMMENDED THAT PANELBOARD-PV ARRAY ON ROOF PRIOR TO ANY WORK UNDERWRITERS LABORATORIES MARKING AND LABELING SYSTEM 969 (UL 969)BE USED AS DISCONNECT-INVERTER 1(855)SOLAR-55 NTS Sheet STANDARD TO DETERMINE WEATHER RATING. -DC DISCONNECT PER NEC;650.56 (B) E3 Series 100 Series 100 American Tucson,Decwnber 31,2013 SnapNraek Structural Report and Calculations Snapfglraeka SnapNraek- A soiaroireer PV MounUtig Systems Structural R.Part and Calculations PV f Or Bllhl(1 SVstf1TIG PIRUECT DEVELOPER Norm•. SnafNnek I V Me..I NI]i t,u hy,II meB0e A0 Solar Direct no. 75 Ft.IanA Soil.200 litbaanmon 606T Allw R.II Tibld LICENSE B/C70/C48%841069 San Left Obispo,CA 93401 O Ate AMERIGX BpWt pRECf NO. "Bede 100 Roof Momt Cover Leiter This report describes,illustrate.and explains,We Strucnuel Calculation packet far We9MIRE BLVD.,eUIIE M 0-300.Roof H.Igbt OBARaEIEB,Geams e b e el SeepNmck's Sines 100 Mounding System,died 4fl2R012. The calculations have been PR:HitsOM419A To Wham 11 May Cowan, p�rand in acwMaine with the 2012 hoprnntimud building Code(me).The could. F111424)2148rEY y s t has been designed m widsland code g Teble]A:Rag Spans pn)for Rpvi 5lPpd antl Tih Aryks O•m 19 600ANI, M:vm awwmn yaght B^ d Imes t e forces due io its own wreighl.de W ES:Htp/MxwamtY mgemrwimm weight pfthe sohrpmd.tits:slow land;end bop the wmtl and seismic forva. and traelvral onheveperfomd provided b fmderses.Included thus sysmm bead IinIE m the infomafion provided by he calcark.easI. wid via Ira are 12 van tics is its iw ra ran as, m m m 1i antl rd-10,2012 We In theSme! mecca 2M2 Iwf IE.9 n] it.l ]69 Ll ])➢ el) aa1 IBC,ASCE d Specimen. NOS,and guidelines sMtd w de seta Amens Board a vRail sid. v - E This repan eaven e m d f t uses a optipm for Om pride)mils. offer s e ; v ive<r for C.odcsand SMndadx Sh they are g _ bed alumivrm.arm mil option uses a 6063 alloy(25 kyi)into)erW de ode U9m a 6005 3 Z ' ' Same of the wrvponmis in the SnapNnck tan data wore used to determine the allay(35 kai ylaid). 8 m is W sou ssCMu. capacity and adfi profanes of modal[.We collected fire tt data using the 5 as do' ) a,Ca mindoorour 1vms outlined in de 20121BC Ch t 1]. Despite having dlf tyieM eOenglha.lmd types ormikaoppan the rV panels.Asfm m at J encess... f aPa the m115 th�selVm,the U latasxmataai Y ate m e espy by coo inclu hardware which attaches than tv de m W We includd de fali0wing ty➢cs of 1oM comldaanom coo sallow,nar.maas roof swctrw with apes that vi cxOrvssd in mchm. RCFm 10 the tables Mivw for roll m Z ryssaors spmsmdersaryingcoMitiamofmilall dr fbeiht. SM1Md cells edge m a>-gel—amo- into our calculations: .no adjushwent(sa III following chards). g requircan ge u W • ASCE 7-10 wind pads fiom 110 mph t0 IN fan 9 and C exposure as tan n a ,^ calegorms Nato for Tables IA then 2H ran m w 'I— V/ • ASCE 7-10 Sdsmic Design Category E 1. Determine de mom hoof hw hh tilt ap I mW rail ells r n u w ro w n n a u En W • ASCE T-10 Soow Leads up to 120 pefgnund snow g g c, y(i Yen are umure,ode 0-300.RmfAeight Uy/ na�r -scataeel,s.E. • Building[with rem roof lief dos up m 60 foot tilt angles I rmfyitchm the 6063 allay velum).For mesh turf heights Imp Nen 30 fed,use fable IA)2A >_ IX far WI angles less than 19 degrees,Table IBRB for fill angles between 20 end 36 U) /LU _ firm OdegreesmbO d.grecs. tlegtga,Table lC2C far fill angles between 37 and 45 it,,.,eM Table ID12D Table le:Rail SWm(in)far Real We.and MArgIm A'to 36' 601i3Alby y TO W E� m for tilt angles between 46 and 60 degrees For mean hoof heigher hetwan 31 and U Z 2 Lo N our opinion,the momnng system outlined by SnapNrack•s Sprint 100 PV Wloe WM N -rrwrrrossma.,® W fed use Table[ME fan till angles kd than 19 degrees,Tabk IMF fan till vau ss us W N Mal,the Syn®Code Compliant tined ianm Manual 20@ is eitepmbic end its LPL anglesbetween20 and36 de Table102U liver fill6degrees. 3]and 45 ash eM a mall the loading rryuiremenis m cord above.see the report and,ymddiurw ��• angles a v4 m r m9 w Q n`ra•i "'e' included with disienaibrmoe information.l digras,mdhe ble vend an hands angles bdwecv 46and 60teegrecs. e,w m2. Ddmmine the who coo mow load for the project site from the building 4 e U Q Sure soh liZ Iftbac me any harder emotions,plems armed Norm Schal. deferment.Make cenainm use 20121BC wind loads. l.aam the wind load in `g m a W W �+ de table.crass lop eons aM de mow land down the]ell selumus m had 9 m Is J LL v deadpanning madman rail span. m an W N W W (I Stow Covers 3. ForsrowlmiL,column Pg ymislhe Bound snow. a m rs 4. Shadd cc]Isasuim application 4anedgemmadjusmrns(demilstoPoUow). O ,n Ur H' W e.wa:ieIte ,is r5kLL a rMewigdsw ansUlal PE,sE A w J J OD Z ^ i-e.m�nuwn irEouapac.i..'11— No.ZW7 tan O J � CW Fnt'AscE Ep.17fJ1ns CO m CV G ?aF PROJECT NUMBER: JAN 0 2 2014 NNE marsou.m.amaeevilPineves sausit tn).1. Rm depsot) NSSE tan learva.affirm cAtmovens),)Q>ma Rw.tl,tned OP-00149111 YSIEM B2E: 9.50KW PV HEETTfRE Simple RACKING puKaeaeemhhand.1..r.-min,truth SYSTEM peso wrcnm era ryWaln me[acem SPECIFICATIONS • • • •L—Pmaainsamwn...r, & EF EIECENCUN Adaptable DANNY MDINTYRE .eomwrmuwnn.rn.aar an mend n rant mge„a[ wuiriwF,paumnwewRnRrcrma olusis,n -In wmwn lnamaManwwa (424) 214-6700 .ase.rmnnela ao.ida,mpm.eD was m recan n, SIENSE ICIO/ Mc94108 Strong LICENSE BIC101GS0B910W The Snaps designetorermOuntil .verthuneld hic.,cusammowiwdrgwwection SySrems is designed its eU t0 reduce total Vernceland homm�W edivamen¢encore superior at installation costs.The system featwez t amn-rre ZZPK echnical innovations proven on more m metal namlrp mrrre[warcr prwa ne than 100MW of solar projects[0 simplify _ Innovative Universal Entl Clamps imtaleb.o and reduce costs. •pw arcane anr.ranmm Lrrame medwe ries' Pitched Roof Arran Simplified a� s •L.,-It.-or Ii,cmes,,hace n1,1IIirames J� The SruPNn.Y eir 1.c M nr S,Slem[an .Lela w.aate ra [ngrna motto coon mWul¢[ r� rcknrvualYaP I'rg, vdtaielPV)modue ,�w Hess's,I'vem5r nrM dYa A nee Dra rnsaw—cl ".er'maranera. -''�;. r•�9 leer evil rw[ uieaaenincw tin slam u e,,r. aDa con cWietll Folzllara SttaWure worlo it, ROOT$Ynlem In 4 Simple Steps: here's .6000SQ'iusalumnum leading rnsuanDOn Danes ar.amievee with-c— _ „11,u, r 1,r, •suiviesa sleet CR ReWdan/leads Dole sraa-in ustanes and lmiv aeiusranlarnmporcnu rNr Nr N:r ix•troe.iVnx d,�Suw Loam) .Galvanized steel n ui rwrmouned sals—use easy z.us .,e Freese soaIhr Ergmar.,. mmen Flom .Clear and black anWiaed aluminum wM1ieacnienng lowenruralleucn mars. In-I rewnkee zr w.,am:na r.cem Installation •Buln4 and elliclen odes, up re3 or neigm advstabirnYal root canne[nan 3.Cnm•eote(flea •Adlu[lablahartlware[o en[We Clean antl level lir.[M1 c or Bla[V)erd rooi .Wany-irae owasoof tla[n' •W.cerp mrlalLmeUl llashmB arexn tool Pereualim, ak..M,ent t'pe D N Ca1c;.9C.,uncations •leitroom.supultait e.a.d.ii—loadseo130P5F AERICAN NAposeC WC.. :s Place Brer nitss'uvfirst:Dora ai ruse DRA"NotaLBNFgERVIAL m. WOM1s on virWaiy ea comppirle'iaNtezroars ai lc a•n5lrppc-in+.e nr� Grounting �LNisner.ElKiritat Equipment Bond{WEEe)orlayrin tops pNLYTola"an INWNa% pN n Sngle wrencesze lore ryseen narevan Dvlss..n�s Warmnty •10Year mataM x9Msmanshmscownload full details at snapnnek<om) WIniscons c.13NATEOBr Corse—aws.ry nor low amlleer rift in se o agrees) -Fails vu:W ru l:6:nV RDoi _ PAuZym tie M(:ItMEMMIp BE - Ai:acnr¢nrs /�.aaa rD.nnela WDvmea..alle,r wire rwwgemenr .Fray"—eoea Snap rack Oou HE Po.. B Ipp MWIMWr 1NENE wRRTENP@Ir64LIXi pF MIENICNi BIXM pNECr @C, PV fl.. ..r.; 1 CAD Rwiaivns cut"tPenernq Snap rack (877)7322e60 wwwSna s.fackcom JEC-CAF/422.14 '.•;n; o HPIPS/04R5/14 /A bh..l SNAP—N—RACK SYSTEM SPECIFICATIONS D1 Di American tj Solar Direct PROJECT DEVELOPER American Solar Direct Inc. LICENSE BIC10/046#941059 solar=@9 Single Phase Invertersfor North America ° LSI ,SlnmvnLsxlRE alw.,aullEaooSoar SE3000A US/SE3800A-US/SE5000A-US/SE6000A-US/ PR 14a4)21a50 ■ FR HN)a1"AND SE7600A-US/SE1000OA-US/SE1140OA-US EI,E'a:uroa°" �, SE300DA US SE3111OWUS SE500DA US SE6000A-USI SE760CA-US SE10000A US SE1140OA-US OUTPUT SolarEdge Single Phase Inverters Nominal AC Power Output 3300 ___ 3840 5000 6000 7690 9980@208V 11520 VA W For North America 10000 @znDy W Max.AC Power Output 3650 41SO 5400 @ 208V 6 0 8350 1680o @ n8V iZD00 VA V Z .. 5450@240V 10950@240V J SE3000A-US / SE380OA-US / SE500DA-US / SE6000A-US / ACOctpulVoltageMin:Nam Max' H 183 208-229 Vac AC Output Voltage Min.Nom Max` SE760OA-US / SE10000A-US / SE1140OA-US zn z4o-z64vac ✓ r r ✓ r r } W AC Frequency Mm.-Nom;Max' .3-60 605( th Hl country setting 57 60 60.5) Nz W W OIt 24 @ 208V i. 48 @ 208V V V Lo Max.Continuous Output Current 14 16 25 I 32 48 A ZLo 21 @ 24oV 42 IS 240V V. GFDI 1 I... ... H Q 0) C7 Cu lity Monitoring, slanding `+ertsx• Protection Country Configurable Yes 1U1.I W V e Thresholds INPUT W W W CO tr0ltty Recommended Max.DC Power" � `',Na �s• Isrq 4100 4aoD 6250 ]soD 9600 12400 14400 w Q Z tLE.0 a1j°N Transformer-Iess,Ungrounded Yes J J CPO Z +h� Max.hiput Voltage _ 500 .._ - Vdc 0 m N Nam.DC Input Voltage 325 208V/350 @ 24oV Vdc Max.Input CurrenP°` 11 13 18 23.5 35 Adc UM 16 5 @ 208V 33 @ 208V Plini NBER 15 5 @ 240V 30.5 @ 240V Max Input Short Circuit Curren[ 45 Adc OP-00149111 Reverse-Polarity Protection Yes .. YSFEM SIZE: Ground FaultIsolation Detection 600kn Sensitivity 9.50KW PV Maximum Inverter Efficiency 97.7 98.2 98.3 Stu 98 98 98 % 97.5 @ 208V 97 @ 208V REETTITIE: CEC Weighted Efficiency 975 98 97.5 975 97.5 % 9a @ z4ov 97.5 @ 24ov Nighttime Power Consumption c .5 _ cq INVERTER_ W ADDITIONAL FEATURES — - — SPECIFICATIONS 7 Supported Communication Interfaces R9485,R5232,Ethernet,Zil(optional) 1 !' STANDARD COMPLIANCE - - CHIEF ELECTRCIPN DANNY McINTYRE Safety ULN41,UL16998,UL1998,CSA 22.2 Grid Connection Standards IEEE1547 (424) 214-6700 Emissions _. _ _ FCC Part15 class B INSTALLATION SPECI FIfAT10 NS Signature-Danny McIntyre AC output conduit sae/AWG range 3/4' mmimum/246AWG 3/4"minimum/8-3 AWG LICENSE B/ClOtG46#941069 OC in ru n n duit size/it of strings/ AWG range 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG Dimensions with AC/DC safety 30.5 x 12.5 x 7/ 305 x 12.5 x 75/ In/ 30.Sx12.5x10.5/775x315x 260 S � SwRch(RxWxD) 775 x315x 171 ]]5x315 x191 min Weight with AC/DC Safety Switch 51.2/23.2 54.7/24.7 88.4/40.1 lb/kg Cooling Natural Convection Fans fuser replaceable) Noise c 25 nrr The best choice for SolarEdge enabled systems Min M n"" Miss.Operating Temperature 13 to+140/-25 to+60(CAN ver5io -40 to+60) F Range - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Protection Rating NEMA 3R �• — Superior efficiency(98%) F ,n a m I:r of a aeB „ - u dF vsul a n m mtiv 8 Fish 1 P b n%zsc eo lasZ'lo,locations wnem l-s meow rnft5er City Rrlvieion/beue OaG F i t L•tl f p 1 M1ryll d /ryl tl!/ d "dr o9 Small, lightweight and easy to install on provided bracket •�a Kish.ra : ry Le re-�. �;In s,mac. M1¢ awr_m„ed • .e r4N P/N.-•a ell¢iM1lf lrrr fFs tint-'in 41-xnr�ryi''nFl(,rr,�Fli erg SF I19N:14-IISF41F1 - Built-in module-level monitoring - Internet connection through Ethernet or Wireless ,waaavma°ImoPEmraF urEa aowFuxcra+c.ma — Outdoor and indoor installation ON NM 1EC MIm1PL,WCIa oxLr ro aE usm lu CONAGIpN Fined voltage inverter, DC/AC conversion only vmxxnlu oeawrwmer /JIEe1GN501AfteIRECr ML He P/Rr0F ixle aDCu EW ISmaE alNA�m m_E-Nmlpn Pre-assembled AC/DC Safety Switch for faster installation ..T.-i-•ram.r . • T„EPwanwxm NP,:a,i OFMIzan iNaoARDRECTNL. CAD RfIW... us,,, - GFRIv1ANv - ITAIY PP.M.i:F - iAPAN CHHOS - ISRn.FI - AUIRRAIIA VJWIN.SOIaredge.Us. JEC-CAF/4.22.14 HP/PS/13428/16 SOLAR EDGE INVERTER SPECAFICATIONS /A Sheet D2 ��American 5oiarr Oiro�4 _ _ __ pRaELT DEVELOPER: Amencan War Direct Inc. LICENSE B/C70/C46p941069 otion An4Ewcv2 spunplREcr Wc. Ren a _ 111�WILSHII2E gI,VO..BURESm LOS ANGFIf$,GgWgS 250W, 255W 26OW PI:(.x.)2lai Rene,S*ia A(42.I g,/ET0 TT EM:va aawyV�wmx r 11 1YEB:NIA/Mrw'anlMamdaNY<mn 39.1 inamea S61n<Ms 3)41rchc r —. ._. Z tmOWhn' w 250W, 255W, 260W — --Kill —� J w omvrr U.1 Bit a mla C11) fn 5 I 0 zprnvml 616aevry Nigh Module Conversion Efficiencies - m (n w 3 -. z O � U Z 2 Lt) m 11 >o 11 11 N O I � vpna9e In# � � � � M W aar.pr, Easy Installation and Handling for Various Applications '•mwWaa — ., 0 in Q w w Q' U � III � U) UU Drawlly OnlY3w Belertnu Fllklenry Mile, S6 xM 163% 16.1% 16.0% Q! � I— w II� Mechanical Load Capability of up to 5400 Pa , J J 00 Z OLo ili�l a w 0) Maaimum POWpllPma] x50W $$SW x60W •• " � v Powerlouppaie 0-KVI 0-.5W 0_15W PROJECT NUMBER Conforms With IEC 61215:2005, M^ameEWeie^ev lses ssaW w.pX I�I�� Maaimum power Curlenl limp 933R 9.39E &53A OP-00149111 .ape IEC 61730:2004,UL 3703 PV Standards Maaimum va.er Vala,1pa l gaa v 3O.4 V 3osv yB rnp l2E: xr.'r crmil current 1Nq LB3 P BHA &95 A r O,-Ormi1VapaaeNoQ 3].4V 37.5V 37.6V 9.50KW PV Value at S,andard7.10inditbm 5TC(Air Mass IS,Imedianve I000W/m',C¢Il Temperature x5°Q MEET TR1E: ao9ool,oHsasleool,ISD34001 Certified PANEL maximum Power lPmv) IB W 189 W 193 W SPECIFICATIONS ZM P memllm Gpl GS7A 6639 634A pp M P r Value,(,mpl 1&2 V HS V 28.6v D HIEF ANNV MCIN7YRE ELECrwCUN Application Class A,Safety Class II,Fire Rating C - - m.a c a y ..nl([t0 nTA],12A 7.20A Open Circuit Vale,noc) 35.9v 35.1V 352'a D1bXlYPFy„FItlUN9ttAepIPERepI Vameaar normal Operating Cxn Temperature.trodgn¢ofgc9W/m',scectimi 1.5,amtientumpenwre3lPc,wird:p 1I Ms (424) 214-6700 Signature-Danny MGrltyre LICENSE BICIOIC46 k941069 cell Type 6inrameartyka11,WorII.,mine4G010lam peain seriez Tempratre Caewtlenl orvo[ Lail �� Glaas XI94 Tranimlxsbry towlmn,Temper-0Glssa Temperature cnewcienlal Uc 0.0ll 4X/'C 6W' frame Anodhea Aluminum Alloy Temperature CoeMtlemialroaa AAOX/'e Iuncliou B. IP651IP67 rated,with bypew diodes Nominal Opendng Cell Tem"exam NOCTI 45°E.pt ]004 sa pimpnsmn '64.6a391a1.6imna, ❑' ❑ 9' 9Sl"v ..mm Gmp 13AWG,39immes _ An ►` material& Welgm 40PIN5 +� _ sox Ded Va/ue F' wwkmanshlp msratunanxmeloredon snpnwmsAbwe u as% E 80% ,'� �. 0 y, eantaioer 21 all WHIR Ocera9ng Tempratue d p� T Ilnearpawer ash palle.pon"nuiner 12 28 a Matlmum5yetem Voltage 1pJ9v0[[UI/aDVDC1U5l Cily R&v 9ian�leeu6 Date 0 1 5 10 3i 20 25 Output q� Plewaper Cnntalner 300 TW AO Maaimum Ynb Fufe Paling 304(EU)/30P IU51 TXIS ANW91a6P9DFpnYCF A AMEWGNSCON ENyVA ANDS PV CYCLE ONLYm)Bi UUSEEowmXnlcun LIB® K \ ImMeY !'4$ir�A WTm WJNXOESIGpp Gr AMEwfAX.m AR Mai INC.NO PASTCETXI6DOGIS"TISTOBE Ol9CLWEDropfXERS W9MWT TXEPwgi'Monc IPERMlS51CN OF AMERICM'BIXMOI9ECT WC. CAO Rvyieione JEC-CAF/4.22.14 ReoeSola.corn HPIPSM426/14 B NOTE: ALL Jr25OM-24/55 MODULES COME IN BLACK f EeLACK FRAMES JC250M-24155 PHOTOVOLTAIC MODULE SPECIFICATIONS prowel N/A Sheet D3 GROUNDING (USA AND GANADA ONLY) // American YOU MUST GROUND ALL PV MODULES,USING AN ELECTRICAL CONNECTION FROM MODULE FRAMES TO GROUND. Generated t) F1t PDF C(eatof©FOXIY SOftWar@ Sol r oire i THIS MUST BE DONE ACCORDING TO THE FOLLOWING STANDARDS: yOX FROJECTDEVELOPER: ERDE 3812W.WASHINGTON ttp://www,foxitsoftware.com For evaluation only. American saarDirectInc. • USE A UL-LISTED GROUNDING LUG,SUCH AS THE TIN-PLATED VERSIONS OF ILSCO G5L-4D6 OR CMC CL 50-DB LAY IN LUGS,OR THERE PART NUNBER1.0 SIT LICENSE B/CIWC46 A941069 PHONE: AZ 85009 EQUVALENr. PHONE: 602)2724559 a x1GM�ERcaN soLAR pREcrlNc • ATTACH THE GROUNDS TO THE EASTING GROUNDING HOLES IN THE MODULE FRAMES. FAX: P�SOLAR TILE FIASHING:FIAT&$-TILE,CONCRETE&CLAY L0S KILSNIREeLVD_SUTE EW • TO ENSURE A CONDUCTIVE CONNECTION USE A COMBINATION OF SCREWS,STAR WASHER AND LOCK MIT TO MOUNT THE GROUNDING LUG INDUSTRIES,INC. ( )272-A336 PReµ`,",�BB B 19.50 X 19,50 BASE WITH T'ID,CONE FX(424)suaiw ONTO THE FRAME Eft DR.••ne �� • PLACE THE STAR WASHER BETWEEN THE FRAME AND THE NUT,USE SIZE N10 STAINLESS STEEL SCREW,WASHER AND LOCKING NUT TO - ----- wEe:nlnw.w..nenaiudemrecLmm MOUNT THE LUG TO THE MODULE FRAME,AND TIGHTEN WITH 5 FT-LBB(6.SNM)TORQUE • THE GROUNDING WIRE SIZE SHOULD BE BETWEEN 4 AWG AND 14 AWG(21.2MM 2-2.1 MM2). • CANADA:T14E INSTALLATION SHALL BE IN ACCORDANCE WITH CSA C22.1, SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS,CANADIAN SPECIFICATIONS [— ELECTRICAL CODE,PART L z • THE TORQUE FOR WIRE FASTENINGS SHOULD BE IN ACCORDANCE WITH THE FOLLOWING TABLE: �+, SOLAR TUBE LIU ¢� MATERIAL ALUMINUM ALLOY3003 GROUNDING DIMENSIONS AND TORQUE THICXNESS 0.03E NON. LLj WIRE SIZE [AWG] CROSS SECTION IMMI] TYPE TORQUE TORQUE TORQUE o S01AR BA$E V[IN-1-1551 [FT-LB Z5] [NM] z a-6 21.2-13.3 STRANDED 35 2.9 -3.9 MATERIAL'ALUMINUM ALLOY O-TEMPERED(DEAD SOM 8 8.4 STRANDED 30 2.5 3.4 THICKNESS 0.019" W 10-14 _ _ 5.9-2.1 STRANDEDI60WD 25 ZI Z8 I U) DID >_ UJ GROUNDING 2.90 z c= � V N U 55 Qto � U j LU W l f LU U) ~ l W ir z � _ J � LU z — 19.50 I U) m N C./l ..¢ I PROJECT NUMBER: OP-00149111 ve�[y i VSTEM SIZE 9.50KW PV MANUFACTURED FROM HIGH STRENGTH COPPER ALLOT WITH STAINLESS STEEL SCREW. NEET lIT1E UL LISTED AND GSA CERTIFIED FOR DIRECT BURIAL IN EARTH OR CONCRETE. GROUNDING TESTED TO UL 461 DETAIU ROOF LAY-IN FEATURE FOR EASE IN INSTALLATION FOR COPPER CONDUCTOR ONLY. FLASHING RATED FOR 600 VOLTS CHEF ELECTPoCIPN ADD A"T`TO THE END OF THE CATALOG NUMBER FOR TIN PALTED VERSION AS SHOWN BELOW. d TUBE AND BASE JOINED i DANNY MCINTYRE UL FILE E34440. _ - WITH ULTRA-SONIC WELD CATALOG NO. GROUND WIRE RANGE LENGTH WIDTH HIS BOLT SIZE HEX SIZE FEATURES N.AE.D.NO. /// (424) 214-6700 GBL-4DB 4-14 STR. 1.150 .315 .625 10 S_ CLEAR PLATE 18366996011 Signature-Danny McIntyre G5L-4DBi 4-14 STR. LI50 .315 .825 IB 6 TIN PLATE is 1 LICENSE B/C G1L-4DB-14 _ 4-14 STR 1.150 .412 .625 114 5_ CLEAR PLATE _ 18966996019 STORM COLLAR OR SEALANT ON STANTION G51--4DBT-14 4-14 STIR, 1.150 1 .412 .625 114 S TIN PLATE 18366996020 FIELD TILE I 41lF '— PROFILE TILE FLASHING �. (CONFORM ALUMINUM FLASHING TO PROFILE OF ICK, Ra W.r/I....I Dora — TILE.) TO MAINTAIN DRAINAGE TO TOP OF - TILE T4S DRAMNG W FMKRrYM MIEgGNSGWi MR cTINC.T DMMNGIS WNWEN¶KMDIS I.. DNL TOBEUSEDINCDNAN,' M verN.DE.IGxATFDeY BATTEN MERCAN SGLAR NREC�I . A UL-LISTED GROUNDING LUG MAY BE USED,SUCH AS THE 18C0 GCL-406 LAI-IN LUG OR EQUIVALENT.THE EJASTING au+CLOSEDTc`TH OTHERSMHOUF (WHERE REQUIRED) RSDLDSRMr NFRERNMIT GROUNDING HOLES IN THE MODULE FRAMES SHOULD BE USED AS THE PONT OF ATTACHMENT TO THE MODULE FRAME. TO ENSURE TNF RRORwRTr.ry RERrnsnox A CONDUCTIVE CONNECTION,I.E. TO PENETRATE THE NONCONDUCTIVE COATING ON THE FRAME,A COMBINATION OF SCREW,STAR WASHER DFAMERCAR sa_AR DwecrwG AND LOCK NUT MUST BE USED TO MOUNT THE GROUNDING LUG ONTO THE FRAME.THE STAR WASHER MUST BE PLACED BETWEEN THE FRAME -= BOTTOM OF FLASHING MUST CAD Revision. AND GROUNDING LUG. USE ALL STAINLESS STEEL HARDWARE TO MOUNT THE LUG TO THE MODULE FRAME. BE ATOP LOWER TILES JEC-CAF/4.22.14 HP/PS/04r2W14 MFFR ICf'.-FS FSR-71`115 RFONIRFMFN[S —_ ELECTRICAL GROUNDING DETAIL (STAR WASHER) WITH LAY—IN LUG MANUFACTURERS ROOF FLASHING DETAIL N/A Sh..1 emu: D4 ���American Solar Direct PRCJELTDEV CPER: Amedcsn Solar Direct Inc. . LICENSE BIC!O/C46#941069 solar =seSolarEdge P©wet optimizer OJ424) 1"70050W DIRE INC. PH:I131)R1181W® --' ao a rM(424)E1"7ffl WJRv rR(1211 R116)W Module Add-On for North America EMweu>Aa,umrumwep . WEB:M9uMWW..r Na o,,E Nx. 0 D250-LV/ OP300-MV/ 0 P400-MV/ OP400-EV SolarEdge Power Optimizer - W OP250-LV OP300-MVT OP400-MV OP400 EV J Module Add-On For North America -INPUT --- - - -_- _ - _ -_ z Rated Input DC Power 250 300 400 i 400 W Q OP250-�V/ OP300-MV / OP400-MV / OP400-E1/ • Absolute Maumun Input Votagel6'ocl 65 75 75 125 Vdr - 1 — MPPT Operating Lange 5•55 5 75 1 5 75 15 125 Vdr w ID Maximum Short Grcuil Curerrt 1150 of conrrcled PV 10 10 7 Act, } ModuleU) Lu O "t . - Maximum DC Input Current. 12.5 12.5 12.S 8,75 Ad, V Z = Ltd Maximum EfficiercY 99.5 % Of 0 � Weighted FRi6emy 98.8 % C9 H M Overvaitaga CateFOry II W Lu V a- _ OUTPUT DURING OPERATION(POWER OPTIMI ER CONNECTED O OPERATING INVERTER) J W 6r UJ Ma.lmum Ovtpvt Clo vint 15 Ad It c 1¢arie i Operaung Daigle Voltage 5-60 WE Q Z co Ld IN- OUTPUT DURING STANDBY(POWER OPTIMIZE DISCONNECTED FROM INVERTER OR INVERTER OFF) J ,J oc, Z 1- Safety Outp.t Voltage per Power Optimizer - 1 Vdc O J CD I LC9 STANDARD COMPLIANCE U) 00 (V2W EMC fCC P rU5 CIa5s R,IEC61000 6 2. IEC61000 6 3 PROJECT NUMBER: Solely IFC62109-1 (class n swre ly i,511 1741 OP-001491 1 1 eti Material UL•94(5-VA).UV Resistant 3nMEM Ste: ROHS Yes — — - -- 9.50KW PV _ _ _ _ _- _ _ IN_S_TALL_ATF_ONSPECIFICATfONS__ _ __ ___ _ _ __ ______ .. _ _ _. ._... — __.- __ - -__ - __ _ HEET TIRE: Mariun m Afioxe]5Vsu m Voltagc 1000 Vm POWER Dimene ons IW. ..Hj 143.2:L0.45/S.63 x R.26 a 1.75 m:n/in OPTIMIZER - - Weipht 450/1.0 gr/lb SPECIFICATIONS input Cornecto MC4 7 TtGp/H+5/Amphenol-Hh GRIEF EiECTRICIAN Output VJrP Type Double insulated:6mm';MC4 DANNY WINTYRE Output Y'v:TE Length 0.95/3.0 0.55/3.0 1 12(3-9 1.6/5.25 m/it DrAxnRByxxewvWsawmiucrmJ op".thng Temprn&,rc Range :ID +65/ 40 -150 -f,/'F (424) 214-6700 pmlecbnn Riling I P65/NF64A4 Signature-Danny McIntyre Relative Hum;day 0-200 q; LICENSE BICIOIG469941069 PVSY INVERTER DE516N USING A SOLAREDGE SINGLE PHASE THREE PHASE 2D8V THREE PHASE 480V �! lPueeer OPbmizersi 6 B 1R +� PV power Optimization at the module-level M9umun:SVing iengto fYla%-mum,itr+ng i¢rngin(Puwrr OP}'+'i'zers) 25 15 '. 50 - Up l0 255-.mGTE energy Maximum Pc,'eE"Pe'SCring .5250 61I00 ]2750 W �• Superior efficiencV[99.5%) Parallel 5tnngs of Differ ell t Le ng1h5 or 0 w.rltatar'- Yes j Mitigates all trees of module mismatcfr losses,from manufacturing tolerance to partial shading coy RaW.IDD/I.sDe ware Flexible sVsten design for maximum space ptfliration a Nextgerleratton maintenance w11h modulL-Ivvel monitoring THisoravmGrs PROPERnar MIEFKwsaV DIRECTINC.ms Module-level+'oilage shutdown to,installer zrid firefighter safety DM NGISCDNrIDENR MDES GNLYTO BE USED IN WNNCr as NTH WORK DESIGNAM-, A11E..W.D'RECT1.0 xD PMr Or r HIS OCCUMEW IS ma" biloaca.100THERS Wrr. rNs PwoRwwnEx PExML55X)X DFPMEAIChVs DBsCTINC Lis W Rwieiona JECCAF/4.22.14 HP/PS10428/14 OPTIMIZER SPECIFICATION : NIA SN.et CSI VICINITY MAP AERIAL VIEW /®American ,-r PRSE ?E -.SS ,P.3w ,;,;:; 340-50 bNG114 E ` American Solar Direct Im. LICENSE B/C70/C46YS41089 `I ' y � 1p10 MEWGW°qM pIECT NG. wEnw,°w1Em° N ANGHF4 fA 'µ21)2'MW —WBI:Ngnewwa•w,arerunemn al Z 4 1 1� W • a.! e ULU ap g ■ �N1 � W PROJECT ° �❑ I' W `w LOCAT.. ` U) Lu m LL (n CN pu..1 SHORES - LANE „I " J It w EJ ay`z`v*v-�- i 31 —_ W U) W W Q ° _ V, I— Wd co e "I - .�s ' e 1I '� z ` .' I LLr-- � Z � AlxEwro4r tea" - -- -. O J W L0 ROAD UI Q N 2 �... .,. li 1E51eY11 'aal■s a I>aaEcrRUANx II w nee OR0014911 PROJECT INFORMATION PROJECT SCOPE APPLICABLE CODES SHEET INDEX 9.bUKW f'V SITE CONTACT 9.54�K1U SOLAR ARRAY CALIFORNIA BUILDING- CODE, 2013 EDITION (CBC) T TITLE PAGE .T t, OWNER: MARY M. I DAVID W. BIWNGS CALIFORNIA RESIDENTIAL CODE, 2013 (CRC) GA CUSTOMER APPROVAL/ SITE PLAN PVI ROOF PLAN TITLE PAGE 29188 TIERRA SHORES LANE (38) RENESOLA MODULES CALIFORNIA ELECTRIC CODE, 2013 EDITION (GEC) PVI.I SYSTEM LAYOUT MENIFEE, CA, 92584 MODEL NO. JC25OM-24/55 CALIFORNIA MECHANICAL CODE, 2013 (CMC) PV2 LAYOUT + CONNECTION DETAIL • E Ec°�uR PHA (951) 146-4163 IN (1) STRING OF 10 MODULES f (t) STRING OF CALIFORNIAPLUMBING GORE, 2013 (GPG) E2 SINGLE LINE DIAGRAM 11 E2.1 LOAD CALCULATIONS JASON ATKINSON APN: 340500010 MODULES ON (1) SOLAR EDGE INVERTER: ARTICLE 690, NEC 2011 CODE BOOK E3 SIGNAGE CHIEF ELECTRICIAN-' MODEL NO. SE5000A-US (24OV) TITLE 24 RESIDENCE ENERGY EFFICIENCY STANDARDS D1 RACKING SYSTEM SPECIFICATIONS (310) 560-3297 02 INVERTER SPECIFICATIONS DANNY MCINTYRE IN (1) STRING OF 11 MODULES ON (1) SOLAR EDGE CAL-FIRE PHOTOVOLTAIC INSTALLATION GUIDELINES 03 PANEL SPECIFICATIONS L�ENSEC10/C46 14D4 DMCINT'rREPAMERICANSOL.ARDIRECT.GOM INVERTER: MODEL NO. SE38OOA-U5 (240V) D4 GROUNDING DETAIL/ ROOF FLASHING 000 (424)214-6100 CSI POWER OPTIMIZER SPECIFICATIONS zz7r CA CIO # 541065 EXISTING 200A ELECTRICAL SERVICE PANEL CONTRACTOR: APPROVAL STAMPS �� AMERICAN SOLAR DIRECT, INC. USE OF BUILDING SINGLE FAMILY DWELLING +� CORPORATE OFFICE (N) IDDA PHOTOVOLTAIC LOAD CENTER 11166 WILSHIRE BLVD., STE. 500, (1) SOLAR EDGE POWER OPTIMIZER PER MODULE LOS ANGELES, CA 130025 (SINGLE PHASE) MODEL NO. OP250-Lv PH: (424)214-6160 / FX (424) 214-6150 WORK INCLUDES THE INSTALLATION OF UL LUSTED DC RATED GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM AT egOFESS/p '' B.vWon/I..u. 'nee PROJECT ENGINEER THE ADDRESS LISTED ABOVE 11 City of Menifee ��eY� t1 JAh N� American qe IJILLT� M., SHAAHIN J A H A N G A R D MS PE Building & Safety Dept. G9 I Solar Direct AS CC 211 N. SUNSET AVENUE THE INSTALLATION CONSISTS OF A ROOFTOP SOLAR & -fJ CA.LICENSE6,cmic4604100 msauwx°■egwetrrov ARRAY, INVERTER(S) REQUIRED TO SUPPORT THE ¢ i?�YU-/ 'L7 Y*' °°1E°A'�wo■ mirvMo INDUSTRY, 35 91144 INSTALLED DC SYSTEM WATTAGE, AND RELATED AUG 1 1 2014 AS BUILT ,T, wa.ro°°Eem.wuc,nx PHA 626-435-9211 * U L 1 ELECTRICAL, METERING, AND OTHER SAFETY EX� �'F` 'a rAmavms°ccm■xrwro°° FAX 626-333-0403 °mo°mroom°mwmour EQUIPMENT. ALL EQUIPMENT WILL BE INSTALLED AS Q' corvsr°vrnox ANO AmvRuceuuus sxauconsown orr aMix"ew"in°w¢c 'rs REQUIRED BY APPLICABLE CODES AND THE LOCAL9•c CAL`EpQ`�\ wmm APPucaeie Nsc Ann awnwc couvs.omcmAr-APPRovcR NEAREST HOSPITAL: ReceivedSFT SR DIRAi,PROlECIS° MOF WORK CAD Rwbi°n° UTILJTY COMPANY. JECCAF/422.14 MENIFEE VALLEY MEDICAL CENTER zw _ Pmna° so HPm6ra2e/u N REF PERM DATE 28400 MGGALL BOULEVARD DURING DAYLIGHT HOURS, THIS PHOTOVOLTAIC SYSTEM I ¢ JECJZfAM.16.14 PERRIS VALLEY, CA 92585 (SOLAR ELECTRIC)WILL PRODUCE ELECTRIGTY IN __ 716.14 _ JZ-ABCC-WV14 RE r VAL DATE ShN{ PH (951) 619-8888 PARALLEL WITH THE LOCAL UTILITY SERVICE PROVIDER Nte r 4�Amerlun L.J � Solar rD ectIm.���� vaaEm OEveLOPEn American Solar Dhect Ix. N LICENSE BIC1 DIC46 M941059 010 MEMoM$°tAR DI UM INC. 1 n19 WILSNIHE (E) REAR YARD 36-II4to WMGF S.o&L 'Su"a EW A W PROP Y LINE PH:(e24)]14 00 W4)21MW I $vie:Np/Aw.a.are.�.e.me PROPOSED SOLAR PANEL SYSTEM (E) BALCONY 1 Z PLACEMENT _�. w o J U w ° (E)2-5TORY 1 W g HOUSE ® IC0 W U) w 01 ° ® ® I� W (A rn N w w of < o N J Luc; r nn . ® . o w w L2 o ® ® A Z 00 LL P- Z m $ O _i Lu ELJ AI A U'J F1 CV L O a —� ■�QEDT NUMBER r M l 1 Z ' 7P_00149111 m LWT&ate: C INY American I 9.50KW r V Solar Direct CUSTOMER INV C&WC SEBCIOC96 1069 APPROVALI DC SITE PLAN PV JASON AS BUILT ON ATKIN7KINSON coxsmvcnGHAN°.M+v vNocmlmPs sx4umHPGaM +Ne�mv.HavAaNanm, ® NAP C BEEN cAma aow°`°ac.auG" '"° (310) 560-3297 $Ef$N.1LL UR-!R]E➢0.°IEC13$COPE OF WOPK p ������ 5214 PMi14d W SI9rldWra-Jason A*Imw /\ ER o. ItEF PEwMrr DAIS LICENSE C10/C46 M941009 1 �� M IIE D OVAL DAiE LEGEND 1 INVERTER WITH / INY l DG INTEGRATED " \I 1 DC DISCONNECT PHOTOVOLTAIC LOAD 10-I" PY CENTER City Re slor/lasuaj De1e AS SULT "" PV GENERATION METER AS SULT Y v.A4 (E) FRONT AS CC a1M,t 1HI8 pUW W°6 PR0Pm1YlF (E)DRIVEWAY YARD PVD PV UTILITYSTEM OPERATION NEC) om w. ON'W aE.ED IN WNP1°rCN WrtX WIXiKOEaMIMTF➢M •MEWGNBIXMgaELTNGtq M MAIN PANEL BOARD PM1OFT18°011�"'aroBE ��. ------� oaaasmmorHEPswmnur IHE vN1oG vmmel PePMasgx w.wEnru1 eaAH onmr xc. CUSTOMER HEREBY AGREES THAT THE ASD SYSTEM WILL BE INSTALLED ON THE SIDE(S)OF THE PREMISES REFLECTED HEREIN (SEE APPROXMATE PANEL LAYOUT ABOVE). FINAL LAYOUT OF CNl FeWeiona INDIVIDUAL PANELS MAY VARY DEPENDING UPON OBSTRUCTIONS DISCOVERED, ROOF CONDITIONS, LOCAL ONCLUDING ANY HOA), COUNTY AND STATE LAWS, REGULATIONS, RULES AND CODES. JECCAF/422.14 HPIPS/D426/14 CUSTOMER NAME CUSTOMER NAME APPROMMATE PROPERTY BOUNDARY JECJ7JAB/6.16.14 (PRINT) (PRINT) SEE SHEET PV.I FOR ROOF PLAN LAYOUT JZ-ABCCA/6/14 .- sheet CUSTOMER SIGNATURE CUSTOMER SIGNATURE 1•_ . CA 0 1 2 3 4 5 6 e e 10 GENERAL NOTES ®� rican Ame I. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE Amer®Irncr LEGEND PROJECT DEVEL(PER: 2. DESIGN COMPLIES WITH THE 2013 EDITION OF THE CRC,AND 2011 NEC, AND ALL LOCAL ORDINANCES Aneedr Solar Dined Bw. JUNCTION BOX ® PV GENERATION METER AND POLICIES. LICENSE BIC1wC0#941069 A FAB 40+4 N.+Ewux EouR raw:m mc. nm vnLExerE elw.,sunE FOR INV PV PV SYSTEM DISCONNECT UTILITY OPERATION `` 3. iHl9 PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE GBG SECTION 1609 TO WITHSTAND A `w�c Ro�+�4aTm� INVERTER WITH INTEGRATED DC DISCONNECT MINIMUM 110 MPH WIND LOAD. �W4)21 1mw DG EEI MAIN PANEL BOARD N Pk:Np ,,.•dam 4. THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND PV PHOTOVOLTAIC LOAD #_� INVERTER-STRING I THE UTILITY IS OBTAINED. B CENTER 5. THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. Z ��_�������������� I _W FIRE CLEARANCE 1 6. IF THE EMSTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS J 3-0' MIN. SPACING THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL COPPER GROUNDING ELECTRODE L) W Z FROM TOP OF RIDGE AND GAB LIE LE. MIN. T. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE W J SPACING FROM HIP (E) Fj, ,LGQl.JY MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. F- (n G M51NG VENT, 4" LU IN. DISTANCE TO AND VALLEY. 8. REFER TO SHEET E.3 FOR SIGNAGE "CAUTION: SOLAR CIRCLET' STICKER TO BE INSTALLED EVERY 10 U) SOLAR PANEL cud RRE u: P° FEET, AND I FOOT WITHIN TURNS, OR 50 DEGREE BENDS OF CONDUIT. U Z 0 1 a S. ALL CONDUIT TO RUN ON THE EXTERIOR OF THE HOUSE (NO CONDUIT TO BE INSTALLED IN ATTIC Of W 0) LAR MODULES, 04 4P SPACE) () (4) CV) SEE HEET PV-2 FOR D STRUGTUR L INFORMATION O ie Q 10. SOLAR PANELS SHALL BE INSTALLED WITH NO PORTION MORE THAN 18 INCHES ABOVE THE ROOF W Le fr (' W iF IMMEDIATELY BELOW. LL ~ LL Lo W L 1 FOR NEGTION TO (9 LL STRUGTU SEE DETAIL °PL H. THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS OR SOLAR VOLTAIC ROLL ROOFING i 1AT`RIAL Z 0 — 1 SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING � Z V. B ROOF-COVERING MATERIAL o J 0) LL 4J ❑ 5 U CO N2Z E ® V 12. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE FliO.ECTNUMBER av e`v li BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC OP-0014911 1 AZ 210°w AT 9E SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. ® ,I � ® rvsTEMsig: a ' . ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANEL 13 T P 9.50rCW rV SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)OR PANEL($)SECURED BY SHEE775 E: REMOVABLE FASTENERS. F 23° SLOPE i-1 FL° Y-1 23° SL E ROOF: PLAN ' 14. ONE- AND TWO-FAMILY DWELLINGS, LIVE PARTS IN Pv SOURCE CIRCUITS AND PV OUTPUT CIRCUITS �� OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUAUFIED PERSONS WHILE ENERGIZED. U ELIFUMC R JASON ATKINSON INV t7 �IO M0.RpREQLV 15. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE PV ONDUIT - DC ' �� a LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. (310) 5560-3297 G XTERIOR INV ' 16. "CAUTION SOLAR ELECTRIC SYSTEM CONNECTED" LABEL SHALL BE LOCATED ON MAIN SERVICE LICENSE C180/C46 R941009 (PAINTED TO MATCH DC PANEL EXISTI G COLOR) PV rx¢E CLR ___ �e yA `� IT. SMOKE DETECTORS AND CARBON MONOXIDE ARE REQUIRED PER 2013 CRC, CSC, CFC. (E)2—STORY 18. ALL MARKINGS/WARNING LABELS SHALL BE VERBATIM SPECIFIED IN THE MORENO VALLEY FIRE HOUSE � DEPARTMENT PHOTOVOLTAIC GUIDELINE (CFC610.1 AS AMENDED AND OUTLINED IN THE MV H I-I +� VD I�y PHOTOVOLTAIC GUIDE PAGES 2-5. ALL SIGNS SHALL BE REFLECTIVE. THE PLANS SHALL PROVIDE • II@ DETAILS FOR EACH OF THE REQUIRED MARKINGS/WARNING LABELS, INCLUDING VERBIAGE, PONT, SIZE, 1u' TI FLAT REFLECTIVITY, AND MEDIUM. THE GUIDE CAN BE FOUND AT: M 0 T EXIS HTTP//WWUJ.MORENL- vALLEY.CA.US/CITY,WAWDEPARTMENTS/FIRE/PDr$/GUIDELINES/ �• (E) 206A PHOTOVOLTAIC201LPDF American City RaARi°./Ie.V. Dm ABBREVAA ONS ELECT RIII GAL Solar Direct AS BOLT cnsn4 SERVICE A9 BUILT 2 vun4 I AZ AZI UTH �Q. y�A DIMENSIONAND CA LICENSE BCIO/C46 p JM PROJECT BREAKDOWN AB OC 0ASh4 (E) EXI TING AZ 180°4 SYSTEM SIZE: 5.5OKW SYSTEM (38) RENESOLA JG250M-24/55 SOLAR MODULES TM�OA TMG6�^O GLR. GLE RANGE STRUGTUR L INF TITTTTT � s V 1L 1 IN (I)STRING OF AO MODULES IN (I) STRING OF II MODULES ON (1) SOLAREDGE INVERTER ORLvroREMvmmmxucwH MIN. MNI M FOUND ON V. L 1 1 MODEL SE5000A-US (240V) " MHOR o`"M"Am° ••-RKIH dRMAR BISECT M.1 V. HO ALGo ;�_-a_ �a o��o ti �Ls �L� SSTOSE EOOSTRUCnONAnv AFTPRO O aes sw ar" IN CI) STRING OF I� MODULES ON (1) SOLAREDGE INVERTER MODEL SE380®A-US (249V) Pw�M WroR�FHNE�MPE RDG. RIDGE 23' SLOPE WMT APFUCARLE NEE AN°Rua°mG EVOES.OwcwAL APPROVE SET SHALL DI rATP PROTECTS SCOPE OF wORa HOUSE HEIGHTS 2-STORIES rs MxERrJ.H eaAR oxEm Nc vLY. VALLEY GAD Rwtiw. J GV. GAS VENT® Pmnam vo TRUSS SPACING: 2 X 4 A 24" O.G. JEC-CAF1422.14 P NO. REF PMhM DATE FLAT TILE HP/P$/042BH4 AV PLUMBING VENT Q ROOF MATERIAL JEPJZ/AB/6.i6.ta AV. AIR VENT ® ATE aEQ. P ova nA RACKING SYSTEM-, SNAP N RACK JZ-ABCC-M14 ROOF AREA: 2516.41 $0. FT snee ROOF PLAN SCALE= 3/32" = I'-0" TOTAL AREA COVERED BY PHOTOVOLTAIC ARRAY: 23 % PVi American solarpirecl mDJEmt1EV krea W is AmMran soar anc. LICENSE B/C70/C46#941069 ao,o/u.Ewcu:!IXM DIIECi rlc. fF. OS.NGEIFS�,G WMb IIE� (E) BALCONY N _ Pao PRE CLR WE CLR — — Z ---------------- r- ______ o II-52 W 12-S1 I J Gv U zW � Q z-51 LLI JJJ U) 11-52 Cl) LLj I2-S1 Of Lu U Z a: � 12-51 U.I (n 04 () p � C;w 11-S2 12-S1 W W (j GV J W r11 GVuj w t 11-S2 ® OD LL _ ® 12-Sl --- - � \ .ROJEC=NIINBER 11-s2 OP-00149111 n-sz 9.50KW PV ' n-s1 Iz-s1 8HEET TIME: SYSTEM American LAYOUT Solar Direct Es, cA.ucENSE eremlcae avaioc9 JASON ATKINSON 12-51 V l AS BUILT (310560-3297 \ Bi9roWn-Jtl Agdr \ corvsmurnon Anv awr vxocmuus v,.,corvioxm LICENSE ClO/GS 9941069 n \ wiiHApiuGBLENEC M'D eLI.X C..P,.1 MPPOVkI) \ SEI SHALL OIRAIE]0.0hCI5 SCOpF Oi WOP% PRE CLR. ______, � 12 Pmn,nosse _ \ PG N REF PERMIT OAT, j 11-S1 (02-S I OR 1y �p I� HOUSE r� ai 11-s1 'WE LEGEND _ LEGEND GAS VENT �• . Q OPL = PLUMBING VENT PIPE CityB.4.bn/bu. Dot. (v- AS BULT Ithh4 ® Av = AIR VENT Ae BULT 2 1n.n4 AB CC I&W4 uEww,o,.,i o�n[cr rz.F� oRANVlpf mrmowxrne STRING NO. vAmavna oocui�xraro.s INVERTER NO. D,A�UCMi YOt/d,oP�1 NC. tii �ti J ROOF ACCESS CAD R.W. .2Y1a HP/PSM4/MI4 FIRE CLEARANCE JECBCC- .I4 -1614 JLABCCAlS/14 SYSTEM LAYOUT SCALE= 1/6" = 1'-6" S. PYI.I SOLAR PANEL ROOF p F TRUSS CONNECTION DETAIL 6991argirficl pmer�can SECURING CLIPS 6h6'X 2.15'B.B.BOLT SOLAR PANEL SNAP N RACK. I 5/I6'B.B.SPLIT LOOK WASHER American SDIW L ble. PV MOUNTING V, SNAP N RACK SERIES IN RAIL SECURING CLIPS SYSTEM LICENSE&C20/G871941009 mt R AIEFIrAx a"u"drEm rHc 1 SNAP"RACK tree W WIRE Ew.9urtEe00 = NAP N RACK* END"MP SNAP N RACK CHIAN4EL Nlf �, F2FA,G V.2 S y Pv MOUNTING t,�Fs H2QSINdlIB POINT OF CONNECTION SYSTEM .a"F SNAP N RACK RUDI R RaN M)21 W m Dk� AT ROOF TRU88 TO BE SNAP N RACK eauAR NBTe„•roP w FLASHBNG W®:RWrlNwan�lyeal•BrieCm 4,-0'MAX STAND OFF G.AYP FLga� 5h6'x Y 56.BOLT I B 1/2'MAX BPAGNG PANT OF CONI�CT�J 5h6'B.S.SPIT WASHER Sh&'X i'B.S.BOLTt She SB.SPLIT WASHER Z ROOF TRUSS AT ROOF TRUSS i0 BE 4-0'MAX _ INSTALLED FROM BACKSIDE OF STANDOFF 2 X 4 R 24'O.C. sro( K B) BADE PRlae TO NSTA LAT J w LANDSCAPE PANEL(NTS) PORTRAIT PANEL(FITS) V w Dh6'5.6 LAG SCREW WITH RAT WASHER SEAL PENETRATION AND UNDER BASE w 2.6'MNMUM EMBEDMENT B STANDARD WITH APPROPRIATE ROOF SEALANT. JJ POINT OF CONNECTION DETAIL SCALE = NTS w I MOUNTING SYSTEM SPECIFICATIONS Cl) wof 21'-3" 4-1-" MANUFACTURER: SNAPNRACK PV MOUNTING SOLUTIONS VQ, W � 0 N 115 FIERO LN, SUITE 200. SAN LUIS OBISPO CA.w401 O Q 811.132.2560 EMAIL: TECHASNAPNRACK.COM U u) (E) BALCONY b'-e` I MoDa-1: w w t' • SERIES 100 RESIDENTIAL MOUNTING SOLUTION Uj x W w Cp MATERIAL& 0 N- n • 6000 SERIES ALUM., • STAINLESS STEEL, GALVANIZED STEEL Q Z Go • i CAL08 +GERC/FIGATIGYJB' O _J_ pM) W L^ i 0 'U 0 •ASCE 1-10 WIND SPEEDS FROM 110 MPH TO 1930 FOR B AND C EXPOSURE .:AT. n N i } •ASCE 1-10 SEISMIC DESIGN CATEGORY E x ; •ASCE 1-10 SNOW LOADS UP TO 120 PSF GROUND SNOW LOAD OP-00149111 i *BUILDING WITH MEAN ROOF HEIGHTS UP TO 60 FOOT TILT ANGLEWROOF `rB'EN"6g' PITCHES FROM 0 DEGREES TO 60 DEGREES. 9.5vKW PST i ® GRGi/ND/NCs BEE TNLE: •❑ •" LAYOUT + 42-3" ® ` ® *STAR WASHER CONNECTION •ELECTRICAL EQUIPMENT BOND STAINLESS STEEL LAY-IN LUGS (GBL-4D5T UL DETAIL FILE E34440) ElECT61CNN JASON ATKNSON i n• APPROVED STANDOFFS TO BE MOUNTED AT INTERVALS TO PROVIDE ADEQUATE SUPPORT FOR MODULES FROM ALL ENDPOINTS. STANDOFFS WILL (310) 560-3297 1 BE SELECTED BASED ON ROOF LAYERS PRESENTED. SISmbre JFNn ASiMm -tr p MODULES SHALL BE INSTALLED WITH A MINIMUM 3 INCH CLEARANCE FROM LICENSE CNNC4ENBHaw IV ROOF SURFACE TO PANEL Z25'r .I e STANDOFFS SHOULD BE PLACED AT EVERY ROOF TRUSS AT 4'-0' MAX zx4 TRuss Q. y SPACING. �F TYP. 24" O.0 iA +� (E)2-STORY TOTAL B OF PANELS E24.84 E.O.R HOUSE AREA COVERED(50. Ft.) AVG. LOAD PER CONNECTION POINT(LI56)American WEIGHT PER 50, FT. OF SOLAR ARRAY(PSF)Solar Direct QOFESSIO Ae B ILTTOTAL WEIGHT OF MODULE5 Qe ®� • A8 WALT 2 TMM cA ucErvs>=SrclDrcNe uv°Iav TOTAL WEIGHT OF RACKING COMPONENTS 356.83 �N4�w'�� Jay°`L'���C n TOTAL SYSTEM WEIGHT U.BS) 1581.03 C QTT wu "'weu®w"rFmiry iioe qq A (U ,e ` IXIT roeEumnmSecrox AS BUILT TOTAL RAIL LENGTH(FT) 258.13 G; W �! �"- eaRIl"'""in 'aAD FiEcr�Rcw corvsmurnon u+u nn�'vaocenuRrs snnucorvroa" % OF IB SNAP N RACK RAILS (122') WRH MPLICABLlNEC pM)9D6DP'GCWFSDRIGPAL MPRDVED -I I nc Nnolt tmrTBl NeRee>ol srr sxuL mcrnre ea�nor woex " OF 13 SNAP N RACK RAILS (162") I6 _ TOTAL RAIL LENGTH FIELD (FT) 266.83 '4jF CIVIL UJEC-W/422.14 42'-6 33.1° PAfil°-0D A OFCALFRLEPERMRNO. RCEPERM1fft DATe B OF SNAP N RACK RAIL 5PUCE5 II JZ NOTE PLEASE REFER TO SNAP N-RACK MANUAL FOR INSTALLATION REQUIREMEN S. " TOTAL B of END cLAMPs 4e RFRarrgeeaovAt. "ATETOTAL B OF MID-CLAMPS 56 LAYOUT SCALE=ITS TOTAL a OF STANDOFF ASSEMBLIES 80 TANA a a OTRNG C4NPk lAesITION I *American coNoucTCR C X4DUCTOR LOCATION NUMBER OF SHORT CIRCUITCURRENT NOMNAL CONDUCTOR CONSULTOR CURRENT CONDUIT FACTOR TOIi AT 68ONDUIT RLEUBB•F) CONDUIT DERATE $eiar DireC1 S SOURCE GROUTS MODULES M SO(A) IMPP(Al VOLTAGE(DC) NZE TYPE CARRYING TYPE PER NEC 310.I6U3X2XC) FACTOR PER NEC NOTE:EXPOSED PROECfoEVELUPFR SERIES 6 OPT. 0 NV. AT OP11M28R (AUTO) CONDUCTORS (EMT) 910.15(0)(2xc) CONDUCTORS SHALL BE American Soler Direct Inc. THWN-21UBE�2 SUNLIGHT MODULE TO JUNCTION BOX 10 8.89 A 18.E A l60Y IS, (PV MRS)U&I ] 3W p1B AT IS0.1+BA Xb8.29.2A WA RESISTANT.EXPOSED LICENSE B/C10/046#941059 CONDUCTORS SHALL DE 0 m1o0.E1WGNsoD,n olRScr Rc. S2 MODULE TO JUNCTION BOOK II 6.03 A HIS A 350V He (PV WRE)SUS MI 2 3/4' (010 AT 150')40A XBD..1A N/A FASTENED TO MODULE Ire wla•laeelw.,WISE em ay 4N1DBEs,G1aoB R N'IODW.E TO JUNCTION BOX It 8.83 A 13 A 350%? We (PV URE)U6E�I 2 5/4' (010 AT I50.1rBA X58n"A WA FRAMES OR RACKING R2Q2149Na0 FOR PROTECTION I X(42412VMRS) W J-DOX BTU15 UP TO INVERTER 98PER 03704a WA 350V a THWN4 6 1' fib AT 15011ISA Xbe•31.9A 31.%,A X6•2112A SUPPORT.ALL C 0KVM Mom:� .1 JUNCTION BOX TO INVERTER 10 OS9 A I6.6 A 3bB H THWIIN-2 2 1' (06 AT 160955A Xb891,SA 31.9A)TS•16.,2A TO BE 2 1/2'OFF THE ROOF.PER NEC UN i JCTION BOX TO INVERTER II H.09 A I6.6 A 3SBV a TNWN-2 2 i' (06 AT 150'S5A X"nl.S.A 31.%A XD•16.B2A lIO.IBUlX2)(C) L JUNCTION BOX TO INVERTER It S.W.A 13 A 35 OV 8 T4 WN-2 ] I• (06 AT I5,0965A XBB•91.9A I 31.9A XS•2B.82A Zr TAeI e 6 AG C40NDUl=0R AND OONWT CONTIPICATION W VOLTAGE ATH x 1.25NUMBER C4TN000iOR CURRENT LAIRRYMCM !8-LTRAL EOIAPMENt GRgBpAJC GROIADING ELECTRODE T REIEBCLA JL250M-]4/BB MODULES INC all AUG OUTDOOR RACED MG4 CONNECTORS FOR MOOLLE �--♦I W CONDUCTOR CONOICTOR LOCATION (VOL PNAe� WffN X 1.]fab CONDUCTORS TYPE CONDUCTOR SUE WORE CO DUCTOR CON DUCTOR IEMT) OI INTERCONNECTION.DO NOT REMOVE THE OUCK CONECTS,OTHERWISE THE MODULE WARRANTY AND THE IL LISTING U(AMPS) 90Y (AUG) (AWG) %0C) (GEC) WW.L BE MVAIIDATED. Z O INVERTER TO PV LOAD CENTER 240 MPH(2P) 16.2b A 2,N GND Two" •IB a10 00 •b 314, •6 AWG BARE COPPER GROUND WILL BE USED AS AN EOUPMENT GROUND FOR THE MODULE FRAMES.USE � 4 20 M ,.LE GROUNDING METHODS PER T14E MANUFACTURERS INSTALLATION REOUREMENTS.THE MOD" ui ...J.1 O INVERTER TO PV LOAD CENTER 140 MPH op) 2B A 2,K GND THW ON-] RB a10 f8 f6 !14• EOUPMENT GROUND SHALL GROUND ALL OTHER EOUPFEHT AND SHALL TERMINATE IN THE INVERTER CABINET.NOTE:GROUNDING LLfn6 USED FOR GROUNDING,SEE GROUNDING DETAILS FOR SPECIFICATIONS. U) Lu O PV LOAD CENTER TO MAIN PANEL BOARD 240 IPH UP) 46.25 A 21 K GND THUM-2 a6 f6 ab 06 I' NEMA SR JUNCTION BOX USE UUATHERPROOF STRAIN RELIEF TO BRING(PV WORE)USE-NWII SOURCE CIRCIT �3 CONDUCTORS INTO THE JUNCTION BOX TRANSITION TO THHN/THAN-2 CONDUCTORS N JUNCTION BOX use TO U) LU O � TEMPERATURE INFORMATION PULL OUTPUT CIRCUIT CONDUCTORS TO SCLAREDGE INVERTERS SES000A-S U40V)4 SE9DOBA-US(240V) U U 0 CIO N 39'C•102'F- ASSUMED HONEST TEMPERATURE SOLAREDGE INVERTER IS NEMA 9R RATED WITH UL 1141 LISTING INCLUDING INTERNAL ANTIiSL4NIDING Z JW60M-74IBD BOAR MODULES NGH TEMPERATURE CORRECTION LOW TEMPERATURE CORRECTION-T•CT ]0'F- ASSUMED LOWEST TEMPERATURE O PROTECTION FEATURES.W141 LUSTING INLWDE6 COMPLIANCE WITH IEEE FOR POWER OUALTTT,EEE929 II.I 4 FOR INTERCONNECTION SAFETY AMID THE NATIONAL ELECTRIC CODE TIED TO EXISTING FACILITY GROUND. I- 0 cr) B.ECTIRIC IlN1Te TEMPERATURE RA TEBt CONIDRION HIGH CHANGE CORBEL CORRECTED LOW CHANCE COR CORRECTION INVERTER HAS INTERNAL PC DISCONNECTION MEANS.INVERTER IS LLL LISTED AS A UNIT.LENT 16 BOUPPED U G� (�DATA COEFFICIENT O TPUT TEMPERATURE TEMP. N TEMP. IS) SNDWATED OUTPUT TEMP. N TEMP. (5) UNDiCATED OUTPUT WTN W141 APPROVED GROUND FAULT DETECTION DEVICE TWAT MEETS NEC 260.121 REQUIREMENTS FOR w (1) (bl'W CO OTC TEMP) <YJ ('W (Y) U4T8) (•C) PC) UNTO EQUIPMENT GROUNDING. NOTE:SEE ATTACHED CUTeNEETB FOR DETAILS. -,J X w 01''POUERPMw ni'•aR) WATTS -0.4 2ne 25 59 14 -5.6 -U.14 214.16 -1 -3] 12.8 12.5 250 PV LOAD CENTER TO TO BE PLACE BETWEEN INVERTERS MAIN PANEL BOARD BEE SINGLE U j U) W ••Y OLINE DIAGRAM FOR AMPERAGE RATING AND MANUFACTURERS SPECIFICATIONS �' W �r OPEN ORCUT VOLTAGE IV.) VOLTS -0.306 314 25 99 14 -4.2% -0.b88 35.03 -1 -A 960E 0.096 40.99 4� � � (L I� PV GENERATION METER-TO DE PLACED BETWEEN PHOTOVOLTAIC LOAD CENTER TO PV DISCONNECT -,L OD r SNORT CIRCUIT CURRENT 0*0 AMPS -0.04 8.83 IS 39 14 -0.bb -0.045448 &M -1 -32 I.M 1.28 e.p9 O METER SOCKET MODLU COOPER DIRE 01 ^ J S lOPV SYSTEM DISCONNECT UTWTY OPERATIONS -TO BE PLACED BETWEEN INVERTER AL OUTPUT A6) 1 m N L CONNECTION TO UTILITY TO COMPLY URT14 NEC 690.N AND LAEC W 020-L TO BE A VI8OLE OPEN PLEAF, LOCKABLE TYPE DISCONNECT LISTED FOR ITS USE OSOLAR EDGE POWER OPTIMIZER 50-LV RATED DC INPUT POWER-250 WATTS.INPUT VOLTATME IkANGM OFJ-00149111-b TO b5 VDC,MAXIMUM INPUT CURRENT-10 ADC,MAXIMUM OUTPUT CURRENT-15 ADC,STRING D TO ILO OPTIMIERB 52W WATTS BTC PER STRING MAXM EI (5250W I ILO ADC•!60 VDC) SySrSW' V 2`7L 0 1.2b8.83•Mara ADC.THE POWER OPTIMIZERS NGLIDE AN INTERNAL CURRENT LIMITING FUNCTION AID HAVE 9.54'KW PV SOLAREDGE OCIAC SAFETY SWITCH O BEEN EVALUATED FOR L401,11INUOU9 OPERATION THE MAXIMUM SUGGESTED MODULE IBC 16 THEREFORE l0 l0-T60 WATT MOOUFb O WO VAC,!2 AMPS CONTINUOUS AMPS,USE OF HIGHER CURRENT MODULES WILL NOT DAMAGE THE POWER OPTIMIZER BUT COLD RESULT IN 8N•fl TURF. INVERTER 1-6 1 SOAR MODUES 41.1 606 O,32 CONDUCTORS ORB REDUCED ENERGY YELD DUE TO CURRENT LIMING(PER MANUFACTURERS INSTALLATION 690.1(AD -- -- __-- _-- -- iMcosJ�b6M24Ee O SINGLE LINE stl 4 PER NEC ARTICLE 6S03b '•PLEAD NOTEUnBYeTEM VOLTAGE ADJUSTMENT FOR LISTED MODULES AND DEUCE ARE MADE M DIAGRAM W%SO-CFC EFFICIENCY BIENCY*-U9 INVERTER I 9B8 CEL E WAC ON•IOU VAC I 2 3 • • 9 iB 1 O 5450 MAX AC POWER OUTPUT EXISTING MAIN HOUSE PANEL MAXIMUM OUTPUT CURRENT TI AMPS 120/240V 1 03 WERE SERVICE EFEIECTRmpN I I HEM OR GRauND-FAULT PRorEcnpN PRwmEo O O O MAIN 20eA SUB BAR RATING JASON ATKINSON lIJL11JBIRE _ PER NEC ARTIGIE 6%.35 1 T x IMp N• INTIERGRATED ARC FAULt PROTECTION 4 (N)IBBA PV GEIgRATION PV SYSTEM DISCONNECT yy�y. Rm I • (TYPE I FOR NEC toll 690.11 GOFPIJAIIGE DISTRIBUTION MAIN LITUTY u )I 4 METER unurr oPERAnON9 SECTION BREAKER SECTIME�RING I `---- ----- � I L L L (310) 560-3297 I W I 60A TO I 116 A Siprrea•-Jaam AtlUrm N WA O b O TO LICENSECID)CONS410BD 1 11 IT 15 • • ]0 21 81 I L----------- -- MAN EGG _�� ____ - SCE METER 1 I GODUT BODY 1 •]0 A WITH PLACARD 22]01I-669165 I - • - ' - - ` _ • p.2 'T l,r=' ____ ____. 240V IPR;tP T a `EMOTING MAIN L__ ______________ GEO 240V IPH,1P BREAKER NONE TO BE • • I I l l l I 60A a PV Bat I MODEL' I COOPER B 1 SQUARE o I I DIE-RATED +� eOLAREDGE DG/F' SAFETY SWITCH HOM612LJBBIRB I MODEL:fNll MODEL D1G7•N RB - L _-____-_ FROM 200A 4 600 VAC,92 AMPS CONTINUOS I -� II-160 WATT N'IpOLLEe 600 VDC,92 AMPS CONTINUOUS I I I 1 I ❑ ] INVERtER1-B 2 B O��UNGROIIDED CONDUCTORS ARTICLE 6150.2161 _ ______GEL_____L 11-2"WATT MODULES • gpLggEpC�SE3S00AYS INVERTER 1 ICHY r_ RavNon/bsu6 8•ls INVERTER 2-S I 988 LEC EFFICIENCY 8 240 VAC N __ _ -1 r___ Y I A MAw4NAM MAX rCPR POWER OIE UNPUT j I AS BUILT M4 I I I SYSTEM GRONDNG AB BUILT 2 VI6114 1 1 2 3 • • I 1 GR PER NECARTICLE b 11��� NET ENERGY METERING NEMU RiORMgnON I TO BE GROUNDED AT AB CC "114 16 Il INTERC�RCWWN ARC FAULT PROTECTION L___�a- ------ EXISTING.EXISTING UFER,SERVICE TwpuwxRserlws2naM (TYPE I)FOR NEe T011 690.11 LOMPLIMIeE PANEL GROUND BUB ANDI NUEarnw sp,vtoRecre1c.Twg PANEL INVERTER NUMBER PTCRATING INVERTER AC -1- OR VERIFIABLE 12MMRI'r Nr6HerIW Np6 MODE. MODEL OF (WATTS) EFFICIENCY NAMEPLATE - GROUNIDING ELECTRODE °Y MUR�oHariwn�rvOa (4) WATTAGE • • L_ _ - I PANELS �i�i�i�i v Irrm�_ _ _ _ I I URENEBOl4 90L.aRmGE •P.V CIRCILt BREAKER npac•lnroomlornmour I u 1 24/6B pE3BB6AM6 21 Me SO 4690.1D AIC RATING- IOKA TxE NlMannRrrrelNOOS•ox u (2+ev) MAIN SERVICE BUS RATING PER °F""R"1GXE01N10^S'Yf'� I N I REE90LA SOI.ARE]X.E (IJ)5/e'COPPER NEC 690.64,105.I20X2) CAD R•H•Ions I T n-241BB SEx®®A-ue M MS 9B 3196.N GROUND O N ROD JEC-CAF/4.2Z14 L_____________ Ec_c U4sv) 200A XI20$• 246A ________________ 8.3 SYSTEM LABELS TOTAL,AC EXBTING HOUSE LOAN 132A HPIPSGM14 38 NAMEPLATE WATTAGE �1� PV LIoAP 46.25A JEGJLA&8.16.14 T TOTAL BINS LOAD- 118.25A 5 240A JZ-ABCC4W14 SINGLE UNE DIAGRAM AND CALCULATIONS - 5.50KUJ SYSTEM - 38 RE ESOLA JC250M-24/6B MODULES / (1) SOLAREDGE INVERTERS SE5000A-US (240V) 1 (1) SE380OA-US (240V) NITS E2 Electrical Load Calculations Electrical Load Calculations ��American eG Ci;C Residence Residence PRO E S DEVELOPER: Address: Sq.Footage of House: American Solar Dived Inc. 3,269 Address: Sq.Footage of House: 3,269 LICENSE B/CK/C46 M941 W9 Calculations Prepared By: Raffi Dersarkissian DATE:4/14/14 Calculations Prepared By: Raffi Dersarkissian DATE:4/14/14 „�°nLsN"E BlVO 8°IIERSp'ND. ��21 c.soros '(424)2Mrmo N2II214-0IW M: MplMnwilMbnwlMJYwi¢m LOAD ITEM QUANTITY X VOLTAMPS OR TOTAL LOAD ITEM OPERATING WATfS QUANTITY X CURRENT TOTAL H (AMPS) Z A.General Load Circuits B.Full Load Circuits WJ General Lightning Circuits 3269 Sq.ft 3/ft2 9807 Mechanical Circuits: IJ W Z Small Appliance Circuits(2 minimum) 2 X 1500 3000 Air Conditioner or Electrical Heater" 1 X 25 5750 W J Laundry Circuits 1 X 1500 1500 Air Conditioner or Electrical Heater* 1 X 19.9 4577 (n Electric Dryer 0 X 5000 01 Air Conditioner or Electrical Heater• 0 X 0 0 U- W Fixed Appliance Circuits Electrical Heater or Furnace` 0 X 0 0 U U O Electric Range 1 X 8000 8000 Pool Equipment: — IZ LO Electric Counter Cooking Unit 0 X 8500 0 Pump Motor(Filter)** 0 X 0 0 0 M Electric Oven 1 X 8000 8000 Pump Motor(Booster)** LJ 0 X 0 0 W W V Refrigerator 2 X 1200 2400 Pump Motor(Other)** X _J Q' W p 0 0 LU W r� Built-In Microwave 1 X 1600 1600 Pool/Spa Aerator*• 0 X 0 0 Q Z LLU Dishwasher 1 X 1200 1200 PoolSweep"* 0 X 2.5 0 D Z Garbage Disposal 1 X 1000 1000 C+ J p�j UJ tL 0 G; 00 N -q on Trash Compactor 0 X 1200 0 Electrical Vehicle Charger:per 2014 NEC 625.14 NUMeErt - Furnace 2 X 550 1100 EV charger 0 X 0 0 OP-00149111 Electric Water Heater 0 X SODO 0 Total Full-Load Equipment Circuits 10327 sraiEMsl Central Vacuum 0 X 1800 0 C.Electrical Load Calculations 3.50KW FV Whole House/Attic Fan 0 X 1600 0 Total,Section B(Full-Load Equipment Circuit)-Amps 10327 sNEer Tm Vent Fan 0 X 240 0 Total-Watts 31,690 LOAD Garage Door Opener 1 X 800 800 Total House Load-Amps(Total Watts Divided 240 volts) 132.0 CALCULATIONS Pool Light 0 X 250 0 Total PV Load-Amps 46 25 HIEP EIPCRUOWI Hot Tub(Spa) 0 X 8500 0 Total combined Load(house+PV)-Amps 178.3 rrm�JASON ATKINSONpMe>ae®p,AHeecrm, 0 Size of Existing Electrical Service-Amps*** 200 (310) 560-3297 0 Proposed Size of New Electrical Service Equipment-Amps 175 signature-Jason Abdrreon LICENSE C16/C46 R941089 Subtotal 38407 *Air Conditioner or Electrical Heater(whichever is greater) Per 2014 NEC (FLA x 240 Volts=Watts) FLA=Full-load Amps Subtract:per 2014 NEC Article 220.82(B) -10,000 *• Pump Motor,Aerator and Pool Sweep(Amps X 240 Volts=Watts).Per 2014 NEC Table 430.248 General Load Circuit 28,407 •*"The Size of the Existing electrical service to be greater than the total combined load of the house and PV Total,Section A x 40%(General Load x 40%) 11,363 Full-Load Current in Amperes 10K Watts at 100%:per 2014 NEC Article 220.82(B) 10,000 Single-Phase Alternating-Current +� Total General Load Circuit 21,363 Motors:Per Table 430.248 ■ NOTES: HP 115V 230V '' 1)240 Volts x Amps=Watts(VA) Watts/240 Volts=Amps 1/6 4.4 2.2 American CRY ReWebn/leave Dote Solar Direct AS E1IxLT nen4 1/4 5.8 2.9 AS ex6LT 2 va4 CA.LICENSEB/CID/CG MIM9 A6 GC IAW4 2)This Schedule is Based on the National Electrical Code(NEC)and is intended as guide for preparing electrical 1/3 7.2 3.6 16g1^ s" 1*� calculations.However,due to various conditions that exist on individual projects.If you have an A S BUILT R.E NeDueo .�,H® p t y any ",,,,,ee,re ,,,,Le,rore regarding the use of this form,or electrical load calculations please contact the Chief Electrician at 626-435-9231 1/2 9.8 4.9 wavrotre uem"carueS rmxroac ofregxAPmer AeFPo(JN souswREcr"c.No 3/4 13.8 6.9 PRATaR Pare ocaLrexrreroeR CONSTRIICIION M'pgNl'pRDCEOIIRES$HALL CVNfORM D"ROemlOOf1EB W11XO1R 1 16.0 B NP AP SF HALLEDIMAR PROIECISSCOPEOOFWORRAPPROVLO �NI eOIM aIflECTHC 1 1/2 20.0 10.0 P uD Remrom sz a IV ffr 9vo A _ JEC-CAF/422.14 EF ERMIT NO. — REf PCaMFr DATE 2 24.00 12 NPmsro4n6/14 -- 7.16.14 JEC-MAB/6.16.14 3 34 17 �Q_BY IAPPAUVAL --DATE JZ-ABCCB/S/14 NT6 Sheet LOAD CALCULATIONS E2 COMBINER BOX/CIRCUITS/ ENCLOSURES 6 PHOTOVOLTAIC PRODUCTION/ NET METERING dAmerican V P SYSTEM Solar Direct PRO.IE4T DEVELOPER: GENERATION METER Ama4pD solm Direct Inc. LICENSE B/CI0/CM#941069 WARNING PER NEC 690.5 (C) ommALffmre =S NEc INC. l 7W misNiRE alw.,sunE soo ELECTRIC SHOCK HAZARD OSANGEES.GBWLWARNING P I"4)21° 0 WEB:NrouM.wa,•nm.awt.e.W,. THE DC CONDUCTORS OF ELECTRIC SHOCK THIS PHOTOVOLTAIC SYSTEM HAZARD ARE UNGROUNDED AND MAY BE ENERGIZED. IF A GROUND FAULT IS W INDICATED, J NORMALLY GROUNDED U W PER NEC 690.5600690.35(F) CONDUCTORS MAY BE QZ EMT/ CONDUIT RACEWAYS AT EVERY 10 FEET UNGROUNDED AND LLI J O ©0 L`J ENERGIZED. CO W PER NEC 690.5(G) } o CAUTION: PHOTOVOLTAIC PV DISGONNECTI BREAKER/POINTS OF CONNECTION V O DOD POWER SOURCE W U) ~ w LC Q M PER NEC 690.31(EX3) GFGhFC 605.11.1.1,605.II.t.4 (D PV DISCONNECT w w INVERTERS ll4 W W c�0 In PER IFC 605.11.1, IFC 605.11.1.4, LL. r CAUTION. NEC 690.15 Q NEC 690.14(CX4) Z CO '^ ^ cRo99 REFERENCE NUMBER wrH BIGNAGE MAIN SERVICE DISCONNECT J C -J L^ SOLAR CIRCUIT v c^ m N L o; 605.11.1 MARKINI6. MARKING IS REQUIRED ON INTERIOR AND EXTERIOR DIRECT-CURRENT DISCONNECT WARNING: MULTIPLE POWER SOURCES PROJECT NUMBER: (DC)CONDUIT ENCLOSURES RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS PER NEC 690.31(EX3)i CFGhFC 605.II.1.1,605.11.1.4 UTILITY POWER @ 240/120VAC, 200 AMPS OP-00149111 605.11.1.1 MATWO". THE MATERIALS USED FOR MARKING SHALL BE REFLECTIVE, �1 DC DISCONNECT ON INVERTER MAIN BREAKER TO BE DE-RATED TO 175 AMPS BYSTEM SDE: WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS PV POWER @ 240VAC, 46.25 AMPS 104 c n REQUIRED IN SECTIONS 605.11.1.2 THROUGH 605.11.1.4 SHALL HAVE ALL LETTERS DC DISCONNECT RATINGS: S.vOKW I'V CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8 INCH (9.5 MM)WHITE ON RED PER NEC 105.12(DX4), NEC 690.64 NEC 690.14(CX4) BACKGROUND. SE500RREN L�� OPERATING CURRENT:21 AAC l�Dler1Ca11MARKN6 CONTENT. THE MARKING SHALL CONTAIN THE WORDS "WARNING OPERATING VOLTAGE:240 V AC CAUTION: Solar DirectNAGE PHOTOVOLTAIC POWER SOURCE". MAXIMUM CURRENT:32 A DC SOLAR ELECTRIC SYSTEM CONNECTED cA ucENse.Brclaic46av41D6sMAXIMUM VOLTAGE:600 V DC605.11.I.D MAN SERVICE DISCONQ�ECT. THE MARKING $HALL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE PER NEC 690.5 (C) �� TT TTTLOCATION WHERE THE DISCONNECT IS OPERATED. INVERTERS PER IFC 690.14(CX1),IFC 605.11.1 B U 11 LNSON 605.II.1.4 LOCA710N oR MARKNG. MARKING SHALL BE PLACED ON INTERIOR AND NEC 605.II.1.4, NEG 690.15 +< NEC 690.53 ( ) 560-3297 EXTERIOR DC CONDUIT RACEWAYS, ENCLOSURES AND GABLE ASSEMBLIES EVERY IB CON$i"OC1O"A1YO""`'PftOCED°RE5 SHAH CO"nOR^+ CAUTION: WARNING: �LE �Ga�n ° �o G l° FEET (3048 MM), WITHIN I FOOT (305 MM)OF TURNS OR BENDS AND WITHIN I FOOT sr�sxALLmnAif rs°recrs score Dr w°ae Signature-Jason AWn (305 MM)ABOVE AND BELOW PENETRATIONS OP ROOF/CEILING ASSEMBLIES, WALLS OR PV DISCONNECT LICENSE CI0/C46#941069 BREWER REF FER NO RTE?M% BARRIERS. SOLAR CIRCUIT BACK FED UAATT SIGNAGE REQUIREMENTS TO COMPLY WITH NEC 2011 DISCONNECT DO NOT RELOCATE _ 7,16.14 CODE ARTICLE 650 MARKINGS SHOULD BE AS FOLLOW PER NEC 690.31(EX3)Q CFG/IFC PER NEC 105.12(OX4), NEC 690.64 NEC 690.14(CX4) aep.Bv/APraovAL DATE 605.11.1.2,605.11.1.4 • RED BACKGROUND DC DISCONNECT ON INVERTER CAUTION \/��, • WHITE LETTERING Y V A U T I O N WARNING DC DISCONNECT RATINGS: • MIN. 3/8" LETTER HEIGHT SE3800A-US POWER TO THIS BUILDING IS ALSO SUPPLIED PHOTOVOLTAIC • ALL CAPITALS OPERATING CURRENT: 16AAC FDiscor4NEcas�ocATED AS SHOWN. SYSTEM CONNECTED OPERATING VOLTAGE:240 V AC MAIN DISCONNECT HAS BEEN • ARIAL OR SIMILAR PONT MAXIMUM CURRENT:32 A DC DEBATED TO 175A City Rwi.w/Is.u• Dote MAXIMUM VOLTAGE:600 V DC AS BUILT 6h•h4 ®• NON-BOLD PER NEC 690.5 DO NOT ADD LOADS TO THIS(C) A9 BUILT 2 N•h4 BRis Deuwwca AB CC PaDEmrcDr •/ah4 (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT)REFLECTIVE WEATHER PHOTOVOLTAIC LOAD CENTER ELECTRICAL PANEL® CONTACT: ,VIEAICµ 80C1Q<LT I16111G RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT U ® AMERICAN SOLAR DIRECT DM NGLSDDHFa)Em MD6 DNLYMBEUSmwmiuumq" NOTICE PRIOR TO ANY WORK w R DESGM. BY THE PLAQUE WILL BE ATTACHED BY POP-RIVETS, SCREWS AND/OR OTHER APPROVED 1 855 SOLAR55 "AE01�'"m'A0.01'f4T1N0.NJ FASTENERS. (GEG 90.T, ue.3) PV SYSTEM COMBINER PANEL I 1 PrRrormis DocDNseR'a roeE DBclosm rootRaravmm°ur ALL FEED AND PENETRATION TO BE FLASHED AND WATER PROOFED DO NOT ADD LOADS TO THIS PANEL CAD Revisi•n. MARKINGS WILL BE PROVIDED IN ACCORDANCE WITH THE GAL-FIRE SOLAR PHOTOVOLTAIC JEC-CAF/4.22.14 INSTALLATION GUIDELINE SERVICE POINT: HP/PS/04/W14 PHOTOVOLTAIC -UTILITY METER-MAIN MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. IT IS RECOMMENDED THAT ARRAY ON ROOF PANELBOARD-PV JECJ7lAB/6.16.14 UNDERWRITERS LABORATORIES MARKING AND LABELING SYSTEM 969 (UL 969)BE USED AS DISCONNECT-INVERTER JZ-ABCC-8/5114 STANDARD TO DETERMINE WEATHER RATING. -DC DISCONNECT Nr5 SR..t PER NEC 690.56 (B) E3 Series 100 Sna�Nraek Series 100 American Tumdey,December 11,2011 /�/� r SnaQNraek` Selaf Direct SI Mp1�ra�k' Strnfira d Repart end Calculation. Puf Mountln(J Systems straaNM RePart•nd Calculatimm PV Mou ting Systems p�mO Off' No.xi.v 775 Ft [t P V MaIIl,uoy Spstebn LICENSE BB/C1e0/C46NB410W JJn Luis arr,swim 930 loboderdon San Luis Obispo,CA 93401 606.1 Affair Roll Tapks 9p10 ALER1GN BDWt ONELT NIG This r describes, dlue0ne,end eR 1Mg N9ENg9E gLVD.,6Ut1Ele0 ,best `SerialW Roof Manot'Cover l.ener aeon plains the Splrmlvel Glcldtiaf PoCk¢I fro &M It.R.M.lghf ANpHEg,GgWLG SuMNmak's Series 100 Mamfing System,dmcd 4n2R012. The aleWeliwu have bean Hd)214rmg T,Wham II May Covcan, performed in accordanrc wide the M12 Iam muaeoal Building Lade(IBC).The lacking R:ism)R1441rgo system has bzn designed to wimsmhd crdo-prasriblf due to in awn weigh,the Tabi,Ud Rag Storm fin)for Real Slopes and Th Aryks g'to 19' 6063A1.by Mooamwmaa¢rewan amp We have feerforned calwletiove for the l W lurid roof mount"syszam based weight ofthe mlmpmela,the mow load,and bosh the wind and seismic forces, wiHLne WE&Iawy .IrammWmuadaon 1 r e r t v rd on ma information provided by SnepNoreek,IachadM wim this Imc ue the Yee reds as ror to on ror rn m sin on E egmd a eWofioem.W.did the edculmins be erroNmee with me 2012 Ran spa., o m9 w T4 EI as n m, s a e s w ` IBC,ASCE 7-10.W12 NDS,and gaidalia naled'w We SOIN A Brace Board This rc ml rover two diR l meredd b ns for the s tam rails. Alllmu m arc o w y rw r a Iv<.r far Cedes and Strrderds. P op'a ys yfr ty R bosh aluminum,one it option use.6063 alloy(25 load yield)and the other erns a 6005 Z Sorge of the.nmpafmis in the SmapNeah lest dais were,used to dmmniaa ma alloy(35 tsi yield). y m rf W_ svnsam.xlw and scrirp fineledals.We mllecrcd maim dale usi me 9 a.n CSm.CAl" s opeelry pnrMniesa se n mid aanu pmndmes outibl in the MI2IBC Chapter 1T. Despite having diffmml yield strmglim,hoer type rfseip auppon the PV{rods.Mine n ar J fmma3 toss) fia ands themselves.flay aresupponedbymountingha,dwme which allmnethemtothe n or m m U W n4wma We included the following types of toad combinations and building paremmers sooteWchee wim Rare that ere asp,emd in inches. Refer to the%hies below Our roil w o m n11 11 isu C Z a..my.nw.a. inlnomalcWeGans: spans radar prying eormifiom ofmil alloy and ronfhcighl.Shledselismquimanlge m m n C Q erne aaiaxmem(rce eera0e r nmeing rnarml. xi m . W J . ASCE J-10 wind surd from 110 mph to just for R and C exposure Iw T a41 am'sme Notafor Tablee]A thm IN ror w : . ASCE 7.10 SeirmicDaigs CnagoryE En . ASCE T-10 Spow Land,of to 120 psfgmrmd mow 1. Dmemrinc me mom raft hoght,tilt mgle,and rail allay(if you a2 aroma,use 0-30%RoofflelgM of Rome usims g.E. . Buildings with mere half heights no I.0farm 01,angles I roof tnchas the 6063 Why value).Fin mum roof heighm leis Use 30IM,use Table IARA IY finer 0 degre,m to 64 degrees. fro hit loss Ihan 19 degree,Table IBRB for fill orgies berweo 20 and 36 (n W O ame_sa Eegfea,Table ICRCfvrfihanglabmwem3Tand45degrvs,andlbble IBM TBWIB:PIISmmPn)imlmaf51cl and Tut Arale2Pn35' 6P63AIby V 60 r=Awd In cm opinion,she mounting eystan radial by SmpNrack's Seder I W PV ror till mgles beweer146 and 60 degrees.Fm mum roil M1vighm bewem 31 and widalm Z = LO Mounting S Code Corr lied!Insmlli fion Mormal 2012 is exceeds and W fro um Tabk IME fro fill=gin lee Hearer 19 degres,Table IFQF for Olt BeN g m® p c between 20 fold 36 de vs roro Iu Be r m W Bd.Corr mess the loading mquiremmt m d.tl phone.Six me rgxm and vlmlaioos deg ai grew,Table ICnc d fro an N de between 3J tied 45 a Iu e a zr i m e are xi sv nut < Q i! (Y) c— Included wim file Inner for more infarrom. degree,and Table lH2H froti0 angles baweev 96 antl 60 tlo&as. P. P. �t V Lj �Nf. ` d""u 2. IIessome, ft wired add snow bad fro the M*t site firm ors huildl'ng o it LL, < _ 5lewgmpb F.F. If mwaue,my fmt6m malims,pkam.ovmd Nam Schad, deprdera 1.Make certain b we 2012 IBC wind loads. imaefe me wind load in g r I IL W rV ♦1 ,® the mole across turn rows and On mow bin down fie left.1.n ford 9 of m w •_J LL v tea' corresponding minimum fail span, m w r I V W W f I teen Cdeksq 3. par snow load,...OR egoala the ground snow. son-we C Snouted cells admire Hmlicafim of an edge yeti adimmrm(Jeede to follow). so oar r sea «is as as N '^ F_ Ws sires 11 , so tea rerYlr WLltlav CD do M LL V� �Y uo.rd Noman Schm3 PC SE A o r . �•.. J ... 11 wilds— LEfprwBo.c.LEsn.AP x,.n.. "a Inn o r G J ~ W n .Me . / * Ear gins * _ I V.km N4O? ?4e ut°'�,dgy PftMCr NIMBER rglsurU9rr�" JAN Oy �014 NR.�R 1nti6ma{x nwl[wtlPeFCYUG9S6M 1916)fM9fkf assurreas XSW Srz35wri¢BuukmdEm'0bfA9M391916)fb9fef ew'.INIINII Op-00149111 so L r bNNETgM : S.JOKW f"✓ bfGET mmm Simple RACKING O—k a[z<mGb a,d vlidnaewrwdi[lmo, SYSTEM .on.wwdcn la,d—,par m%...rem SPECIFICATIONS CHIEF EtECTMCIAN Adaptable JASON ATKINSON .onsiones d r.nuaay.a mine 11.11 moo,le, m�rtea dusm.[ [mdr dm,— iwmlLaanwn<r< (310) 560-3297 w, nd os,<put—con—sM. .o.ewi..ma.aeensm Slpnaume JB A6dsgon _lu strop, LICENSE ClOIC46 M1009 TM Snsis decline !solar mrto 'fl:, .cdlem mem:e,arm I'd--load,vow«non systems Is designetl to reduce total i chmiatUn Coomic esystem features vemd.I am nwieams aarvnm<n�enra.a.,p.,mr m terhnic&innovations proven on more •nalotgnem.rar mmrq ensures wa,drw—nry than 10OM W of solar projects to simplify Innovatlw U.I.enal End Clamps installmo,and reduce,costs .or<son al-Irmor m c oame min ue, �F •Clean look-so..."it-dr es,'...".o.me, r� P.t.vf Roo-Annular Simplified ad r • rs were rn Nngmz.relcM1 n moll na,.rea a iF 5 N - r0 Iss 5 e ta - nx 1. - A a 1 i 1 an- In •i mnn x o A - a[aoy w .rq laded•,. _ ._. •%�,�~ ayaR2 ' ❑. a m 9 .ror. se Inn' ode rue 1 1 1 Roof System In 4 Simple Stapes e ' •. a me t 11 m Hmnlols .Goons,I.alumparer spa Date n .sn mess neat F�1TlencaD AB BUL7 M nap ror a r.,n n r. ear L, a. .Gamamzea et«I —lo ,In .. material Eneh .cedar one wan a:weuea.wmllmm Solar Direct Ae BUILT 2 T-IanA wn [n[vn9 carer par ar[n<o[.. 1.c, I,iY ar wrv..int na[r'.c.m. Imdeltallrn .Ouckand divided,mormmn9 .unl.1..,na9M 1dednmmy:9•om,—mnn. s;s>wsry cnk•¢Im-n•Mecurerd roar •Aeiunable hardware!Demure cleanena level finish CALICENSERICIOIC46p9Uf169 ABW ladill •w......Iewelerpand awho9 TagpMWNp BPWPFR1YpF •W.reryroul ldllmeral llar.nq al exnrunr ce.M.ariclr anicnnuzr l.T.e CBICS.e CnlnGtions •Wodsoco nel.150 MPH andsnvx lraesmoh is, NENCNIVIXMp1ELTNC.T® e11don 1.dv,1 •wa:u n•rvnu.yeu[m:wn,nunam.ree wed. M' Gmdir unx Wmhw..Elf-Beal Evervianz Bond(WEER),,le,-1,Inns pLYro.EUaan IM WNkIL11p11 Sngle a.¢ndnsze lo.ell[,roam Mrd�are Iv adsli}'.al siv,na,-n 1 Warranty .IpY¢ar maRnal anp work.mensnip(tlrwnlred ow al umpnmek<om) AS BUILT WItXMgi140E6gMAlmpY -Bnl.Y.i .C4,n: PTEDOCVIEMNITE •<mrqu.aeazi,Y e¢law pro4la woe lO60 Mgreerl ,pa rA:'.r�M, uenm®ro ollaltg varxd)r .nan[I.anaen nwiad<,an.m wedm,m,naoam.nr Snap rack eoxs'rnurnoN Al4DA.uv vaoeEODxfs slue confoRM n<Pmonmmnel rEmn9oa Snap 15 wed'1'BAPUI LEn CANOxW.DWGCODES,ORMINAEAVPROVFD Uf At1ERtLJMyryppPEyl.y SETGBALLmCf PROJECTSSCOPEOi WOM k B =: E61 . ..s,:.,:a<k<rm GB Randalln. Snap rack- sE l4 SUvEn' 0 A JP/PSM4=14 .14 p _ REP PERMR NO. Rp'PERhfII OATS HP/PSA42BN4 " 7.16.14 JECJZIAM.16.14 REQ.BY(APPROVAL GATE JZ-MCC-0/6H4 SNAP-N-RACK SYSTEM SPECIFICATIONS p) T---- American Solar Direct Ame&PI tMav DhWuW Eder I2lncl Inc. LICENSE 6CIM184WIN9 Single Phase Inverters for North America solar_ =ee solarSE3000A-US/SE3800A-US/SESOOOA-US/SE6000A-US! xe")2) SE760CA-US/SE10000A-US/SE1140OA-US was,ftw .4.eu,.a.a4em�e SE30D0AUSij -US S.E.6.0.M,.A. US SE760CA..U,S i SE000 AUS .-.S.E..140O_A U OUTPUT SE3800A .-..-.-,. = wSolarEd a Single Phase Inverters ,Nominal AC Power Output 3300 3840 5000 6 0 7680 9680 000 @24DY 11520 VA 5400 @ 208V For North America Max AC Power Output 3650 4150 5450@240V 6000 8350 @D 208V 12000 VA IJ— Uj Z Du 10950@240V. SE3000A-US/ SE380OA-US/ SE5000A-US /SE600DA-US PutydtageMm.Nom.-Max'' I g 08-229 Vat W SE760OA-US SE1000 A Output Voltage Min:Nom Max.' / 0A-US SE1140OA-US/ 211 z4o-26aVac ✓ ✓ ✓ ✓ ✓ ✓ ✓ } U) A Frequency Min Nom Max.' .3-60 605( th HI country setting 57 60 60.5) 1. Hz a) LLI O Max.Continuous Output Current 14 16 24 @ 268V 25 32 48 @ 208V 48 A (,� Z = 9 21 @ 240V _I. 42 @ 240V fV -` Utihly Monitoring,Islanding I ccoo xgvarte, Protection,Country Configurable Yes r Z5 $ Thresholds _ _-_I __ _ - ...I IY U - ' INPUT _._.__ .. �UJI � 1 years q � _ _ _ ' , 9 CD Recommended Max.DC Power ' j ti s Wart RC 4300 4800 6250 7500 9600 ` 12400 14411p 'N ^ Transformer-less,Ungrounded Yes Co Max.Input voltage 500 Voc O J On,. 41 m � M.DC Input Voltage 325 0) CV 208V/350 @ 240V � Vic_ ti ' 16.5IS 208V -- j _i.. Max.Input Current"' I 11 13 18 235 33@208V : Yfr Mir-Elt 1ss @ 240v 3Ds @ _ ,Max,Input Short Orcuit Current 4s 35 Adc Adc OP-0014y 11 1 Reverse-Polanty Protection Yes - _. Groum'um I vIsolationciencynon 600k98.3 Sensitivity 9.11�K PV Maximum Inverter Efficiency 9Z7 98,2 9g 3 98 3 98 98 .�� 98 % . 40Y C C Weighted Efficiency 97 5 I. 9g 97.5 @ 208V 97 5 I .97.5 97 @ 97.5 @ 2V 97.5 % ersr7mE: ..... INVERTER b Nighttime Power Consumption � - ADDITIONAL FEATURES - ------ < .5 _-- ,.-._ - _ __-. _ _ <4 - _ _ w -- SPECIFICATIONS Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) STANDARD COMPLIANCE JASON ATKINSON Gris d C�s FCC echon Standards- - --` -- - -� - UL1741. IEEi1 Emissions dassBB (310) 560-3297 INSTALLATION SPECIFICATIONS AC output condwt size/AWG...So 3/4"minimum/24-6 AWG 3/4"minimum/8-3AWG I LICENSE aCIO�C48 iND4089 _ .. -_ DC input conduit size /of strings rags/ �' 3/4"min mum/1-2 strings/24-6 AWG 3/4' minimum/1-2 strings/14-6 AWG AWG range Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x Z5/ I in/x Switch(HxWxD) 775 z 325 x 1 30.5 x 32.5 x 10.5/775 x 315 260 72 775 x 315 x 191 mm - - - Weight with AC/DC Safety Switch 512/23.2 54.7/24.7 58.4/40.1 lb/kg CoehoB Natural Convection Fans(user replaceable) Noise <25 <so d8A 1 The best choice for SolarEdge enabled systems Min.-Max.Operating Temperature -13 to♦140/ 25 to 160(CAN version**** 40 to+60) -F/-C 17� Intiiatecl arc fault protection(Type 1)for NEC ZOli 69U.11 compliance F'.tectioi Hating NEMA 3a .. .. - �. — Superior efficiency(98%) r rh al m g of uesw tdg peon n eat s%r 1 a he Ih ye HY , hi,h 11.11. aNwr)]i/25C nam 135%f I4unons" Nis Nebw mr/lsac — Small,lightweight and ea to install on provided bracket American �e on 14 ° e : xn / i mi / ar e�d iti �a ar 7JEC-J?JA6M.1&14 'a�OA/�"' DOW ry P ahaha �r .ru ,m m .wn4ma - Pu..u,renr�P rh i sar�a B BUILT +Built-in module-level monitoring .Solar Direct "'a 1nN P/N. n ngNi m.rhr nm.n rn n imn_IR_ nT sn 1401AM IAr ) BUILT] M"4— Internet connection through Ethernet or WirelesscA.ucENSEarclo/cAsx°41osg .�io.enT'1°^+.aur ograr xra Iris— Outdoor and indoor installationAS BUILT °�"`�eeuemrxw%gcrxxa— Fixed voltage inverter, DC/AC conversion onlyw°fw°�eg�r'®c:orn rxx altar�ro ea- Pre-assembled AC/DC Safety Switch for faster installation CONSTnucnDN ANDA PRD UMS Sa CONrDg,aw�.nO11e�r`,e w�,�gOi,Agg�.ggg`.dswUSA - GFRNAANY - 11A1Y FRANCF - IAPAN - CHINA - ISRAFI - AIISTRAIIA WWlM.S �dr rioaatac PMrinn°4m M22.14RErPERhM DATE 4zrat4 6M.15.14REQ.BY/APPROVAL DATE -1W4 SOLAR EDGE INVERTER SPECIFICATIONS D2 American Solar oirew PRENECrO OPFR: o _ Amadoan Solar Dimal Inc. Virtuslla LICENSE BIC101C46 N941060 A15AtElUCM,adARpRFGr PIO. eneSfflaR 25OW, 255W, 260W ;,; w pa.m..aRM.waeRrmr 5�9prww.m.1{s.b.{mni . • _ 39.11n[IMs. 1blr _ 37.A Irchc_ 250W, 255W, 260W AA ° -- w J 2 g OW WM• U.1 a p fn aUJI Bmaan[y . High Module Conversion Efficiencies „ s zSGwma I V O 3 w. mlw a, ° io Z. { w R .P V N ZLin O a vrxaWe M M Easy installation and Handling for Various Applications �T-. 8UJI W � LU It !�®V a _� xF: �goww wowra $*Winn• LU J1 f0 ���a� Ra "¢ Ellkl my 15.gR 162% 3639t I6.1% 16p% N f3V I I !11cc LL Itt Mechanical Load Capability of up to 5400 Pa STCt Vj F Z - ll�iW o =.1 I Cm . to M ialmum Power lPmaal xspw zssw x,w m N � � Ppwer Tder.n¢ 6-nw o-.5w o-.sw wl'DCS'rn1aE6! Conforms with IEC 61215:2005, M°°ukBffidemy "AR 153% �P-001�9111 6®� IEC 61730:2004,UL 1703 PV Standards Ma.imum Power Gr¢nlllmpl 6 a31A 6.Ep 53A Maalmum Power VuhaBewmpl 3alV 3BAV WAY rm�: Lw,I CV[ull Cunmllls[I 863p g.wp 895p - ,fig' Cpen Clrwh Vph,ge lVod 3fAV 37.5V 37,6V 9' 50Kyy pV Woos BWndard Test Cardhbm STC IAr MassAMS.S,Ir,WwK .10WW/m1,[ell Tempearure xY) Pt(FaalllE: , ISO9001,ONSAS18001,IS014001 Certified ,r :, PANEL { MaaMum Power IpmarJ I63 W Now 03 W SPECIFICATIONS Matlmum Power Cunenlllmpl 6,57A 6.53A 5.74A Maximum Power VabeBe lvmpl $82V 9b.SV xAV s•terosl..� JASON ATKINSON Application Class A,Safety Class II,Fire Rating C - spnm eirwan..emllwl 7.12A INA 717A _. Open Clrmlt Vdlape lVuJ 95.0V 35.1V 353V VaWeal NvnulOcemXnBGII TemperaNrq lmEbn¢ofPopW/M,epe[WmpM i.S,ambient tem¢p[urt1G°C,vlMspeed]Ma (310) 560-3297 alalNbinl-Jaacn AWnwon LICENSE C10W4a aa41066 COT9ce 6mawWNup nlPpMmtanbe2 wlmplpamreriv Toro......ecoemuemelV. a.wRre U we GW,s RW ttaramlssbn,imvwn,Temp¢rPl Glaze Tem,e¢ure Qefiaentoflsc ao,%Pc G' Frame AnoB[eD Wuminum Aby Temperature CoeMtlenlof Pma. 4A c n IDO% Iuncuun Box INSAP67 mted,wah b,paas dlola Nomlrul 0pemdn6 Cell Temperature(NOC) ArM-c n d` Oimemon IZAWG9.AWk.hs � $S9$ pueµit Gble 11AWG,39A M[Ires u4�r soB Added � materia& d workmanship wmewarat nW,L...W BSY Value wsese albaa wlrG pbpse O i eongaine. zW GP WGP WNa Operaprg em,oratum n 0% yp linearpower Pallets cercnnelner 3x x x k'w°It/bw 0alm O 1 s 10 25 20 15 Fr output we¢exrronulm, BOB 7oB no mxxjm mSen.Fu mb M(E /6B5*menc Maumum5eriet Fuse PaXng 75pp 2dA ,4Sfg�T MA YEAR smart - d ��. INblar Direct Ae OULT z IvwBA4 �.m�nm� � �•R ,•��•r- CAIICENSEBICI0ICa6p991659 AS CIC I&W4 c�05 C E ❑❑ !sY..; - ,�s � CzuY:-;C LEf PV ;M AS BUILT MBI°M At{{MMmEEDMEwP4WTnagMIl�OeIml 1O -PM —. PMSCF31O0p1]aa31I{lOE o{¢wmroo71ga3mxwr LONSIRUCfION ANDpNI'PRCCEpU SHALL CONF9PG1 71EIwAt Wlang,PgaaEN wrI11 APPLICABIF NFL ANO BUROL\'G COp .UPJGPALAPP0.UVEp aPpaa3RJNgMpaY4TNC. S Ef SINCE pICTpiE PRGlECT55C PE Oi WORI[ t✓b aaYIaIBM 2i TI10G090 JEC4-A!7922.14 REF PER kFne50la%. ff5R'"IF DATE HPIPWOMAM4 NOTE: ALL JC250M-24/55 MODULES COME IN BLACK a 5LAC FRAMES 7A614 JECJZ/A&0.18.14 REQ.BY DATE JZ-ABCC4M4 JC25OM-24/55 PHOTOVOLTAIC MODULE SPECIFICATIONS D3 GROUNDING (USA AND CANADA ONLY) YOU MUST GROUND ALL PV MODULES,USING AN ELECTRICAL CONNECTION FROM MODULE FRAMES TO GROUND. '' Amariaa T14I5 MUST BE DONE ACCORDING TO THE FOLLOWING STANDARDS; enerated by FOxlt PDF Creator©Foxit Software Solar Direct httpalwww.foxitsoftware.com For evaluation only. PRaEcr VE Lo R: �E RD E 361E W,WAZ 85ODON Y AENSE n Eder 45#9410 • USE A UL-LISTED GROUNDING LUG,SUCH AS THE TIN-PLATED VERSIONS OF ILSCO GBL-4D6 OR CMC OL 5e-DB LAY IN LJGS,OR THERE PHOENIX,AZHINGT PART Nw .foxitsoft LICENSE B/Colar Dh {t Im EQUIVALENT.H PHONE 602127E-4559 ®2ptD AMEPoCNI30lAR gPo:Ci LNG 069 • ATTACH THE GROUNDS TO THE EXISTING GROUNDING HOLES IN THE NODULE FRAMES. ( 1°SOLAR TILE FIASHING:FIAT&S-TILE,CONCRETE CLAY ''i 11766 WSHIREeLVq,$WEW • TO ENSURE A CONDUCTIVE CONNECTION USE A COMBINATION OF SCREWS,STAR WASHER AND LOOK NUT TO MOUNT THE GROUNDING LUG INDUSTRIES INC. FAX:(602)2 1-0336 LOSANGELES.CAe S Ono THE FRAME. 19.50 X 19.50 BASE WITH T'I.D.CONE PK 1424121"7W Px:F2p 21"70 • PLACE THE STAR WASHER B EM nw,¢nxryu•wu,caumvpc,.µw.ETWEEN THE FRAME AND THE NUT,USE SIZE MIB STAINLESS STEEL SCREW,WASHER AND LOCKING NUT TO - ------�--�--- -------�--- - MOUNT THE LUG TO THE MODULE FRAME, AND TIGHTEN WITH 5 IeT-1_156(6.8NM)TORQUE. • THE GROUNDING WIRE SIZE SHOULD BE BETWEEN 4 AWG AND 14 AWG(21.2MM 2-2.1 MM21 s • CANADA+ THE INSTALLATION SHALL BE IN ACCORDANCE WITH CSA C22.1,SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS,CANADIAN ' SPECIFICATIONS ELECTRICAL CODE,PART 1. Z • THE TORQUE FOR WIRE FASTENINGS SHOULD BE IN ACCORDANCE WITH THE FOLLOWING TABLE; 4t-, SOLAR TUBE GROUNDING DIMENSIONS AND TORQUE 2 MATERIAL ALUMINUM ALLOY 3003 W 035•NOM WIRE SIZE [AWG] CROSS SECTION [MH°] TYPE TORQUE TORQUE TORQUE z THICKNESS 0. Q LL ON-LBs] [FT-LBS] [NM] N SOLAR BAD Q a-6 n.2-13.3 STRANDED 36 2 e 3.8 MATERIAL:ALUIdINIKdALLOY D-TEMPERED(DEAD SOEf) LU J 6 e.a STRANDED se 2.5 as s THICKNESS0.019" F 1e-14 _ 5,3-2.1 5TRANDEDI60LID 25 7.1 28 - U) GROUNDING 2.90 'O.IO V U O � LY LU fn 04 H U !n < �cw f� L1J (D LJ IL11� - IY C9 I L -�I J J Z a�- 00 O - �� 19.50 - 1 n m N2 S" R•we T3JFE NUMBER' OP-00149. 111 BYSTE Nm p .MANUFACTURED FROM HIGH STRENGTH COPPER ALLOY WITH STAINLESS STEEL SCREW. € S::E_TTTLI::9.50KW PV OL LISTED AND CSA CERTIFIED FOR DIRECT BURIAL IN EARTH OR CONCRETE. GROUNDING TESTED TO UL 461 1L DETAIL/ ROOF LAY-IN FEATURE FOR EASE IN INSiALIATION r� FOR COPPER CONDUCTOR ONLY. a FLASHING RATED FOR 600 VOLTS HIT ELECTN" ADD A`T'TO THE END OF THE CATALOG NUMBER FOR TIN PALTED VERSION AS SHOWN BELOW. ; TUBE AND BASE JOINED JASON ATKINSON UL FL NO.e. _ WITH LI7RA-SONIC WELD 4NNan�/tlEWLNISCUPq•eCLLM CATALOGOG NO. GROUND WIRE RANGE— LENGTH_ WIDTH HEIGHT BOLT SIZE HEX SIZE FEATURES _NAE.D.NO. L (310) 560-3297 GBL-4DB 4-I4 5TR LISe .3T5 .825 le 6 CLEAR PLATE _T8366996011 SlgnaWre-Jason Atgnean GB -14 STR L-4DBT 4 1.I Se .315 .825 IB 6 TIN PLATE T8306886eia I LICENSE C70/C46MNn1 G5L-4DB-14 _ 4_14 STR. I.ISe .412 .625 114 5 CLEAR PLATE_ 183669960IS STORM COLLAR OR SEALANT ON STANTION 069 GBL-4D5T-14 4-14 STR 1.16e .412 .H25 114 JS TN PLATE 1836699602e FIELD TiLE M ALUMINUM 0• A G *PROFIILE OF a ReY1S1eD I.eMe Sa e TILE 0an AS BU LT &h&h4 AGES ��t AS BUILT 2 lhoh4 cA.LR'e ert6ft ewloa3 AB CC WMA TILE TKSpPA GISPRpPER M �• - - .. ,i 0.`AEgLPN 3pWigRELTINL.TN3 BUILT T T�T p MN1NGI3GNigDENIIRLM`p15 Acp ,LRj _U L ONLYTOeEUSEDINGWWLTON A E. WJRM0E9GMMBY RMEWCM'£DIAP CT M. A UL-LISTED GROUNDING LUG MAY BE USED,SUCH AS THE LeCO fidSL-4DD LAI-IN LUG OR EQUIVALENT. THE EJCSTNG - r@ PMTMT SD MEWISTOSE t`T r•M-nl unr•J1 gef1mmE DOems NRMOUT 5 €L5. U1lgCL.FLJ1{r)IRCQI)'lDl HnI.I CUNTDRM THEPR.w M PERM M GROUNDING HOLES IN THE MODULE FRAMES SHOULD BE USED AS THE POUT OF ATTACRIMENT TO THE MODULE FRAME.TO ENSURE w11u arrt AAq� r ANn I me ORIGmAL ArPROvrp OPAMEPoGNSWJigRECTIxr.A CONDUCIVE CONNECTION,I.E. t0 PENETRATE THE DI NONCONDUCTIVE COATING .T THE FRAME,A RUSTBECOMBINATION A SCREW,STAR WASHER BOTTOM OF FLASHING MUST "1 3 mu NInAIT rsoncr3 uoPl OT wOR� AND LOCK NUT MUST BE USED TO MOUNT THE GROUNDING LUG ONTO THE FRAME.THE SCAR WASHER MUST BE PLACED BETWEEN THE FRAME CAD ReviWane AND GROUNDING LUG. USE ALL STAINLESS STEEL HARDWARE TO MOUNT THE LUG TO THE MODULE FRAME. BE ATOP LOWER TILES s 2214 __ PMn4.gYiw JEC-CAF/4.2ZI4 RFF PFRMII'NO RFT PI':RMR DATE HP/PS/04/28/14 _7FF7S JECJZJA9/6.16.14 RCV-UYl4PPROVAL cAli JZ•ABCC8/5H4 ELECTRICAL GROUNDING DETAIL (STAR WASHER) WITH LAY-IN LUG MANUFACTURERS ROOF FLASHING AI DETL NIA Sheet D4 ���American Solar Direct PROACT DEVELOPER American Soler Cited Inc. LICENSE S/CIOIrA6#941069 m1B MIERGN souR DiREcr xrc SolarEdge Power Optimizer "'�wa�"'RER`PD.BD�54D solar - solar - - `�ARDExE670) S FX(424)214 59 '` Module Add-On for North America A:.­�m Vaal:5R4,A.•x r OP250-LV/ OP300-NiV/ OP400-MV/ OP400-EV SolarEdge Power Optimizer W - - - -- OP250 LV OP300-MV OP400-MV OP400 EV J Module Add-On For North America INPUT _ _ -___--_ W Rated Input DC Power 250 300 400 400 Vol OP2i W Absolute Maximum Input Voltage)Voc) 55 25 25 125 Vdc 5(� 3©0 40 40(l U MPRT Operating tangs 5 SS 5 75 5`75 15 125 _ Wdt (n W Maximum Short Circuit Current(Isc)of connected PY 10 1❑ 10 7 Ark >_ ' Module CO Lu 01 Maximum DC Input Current 12.5 12.S 12.5 8 75 Adc — Z = LO Maximum Ettiaerxy 995 % IX LU U) N CD Weighted Efliciv.my 98.8 % — O7 OvervoltageCategory II f LU V OUTPUT DURING OPERATION(POWER OPTIMI ER CONNECTED O OPERATING INVERTER` _ J X IU W I_ Lu (o Maximum Output Current 15 Ark ~ LLI• st h 251W� — OpenatingOutputVOlW le 0ge 5 60 Wit Z sHG6tt>i OUTPUT DURING STANDBY(POWER OPTIMIZE DISCONNECTED FROM INVERTER OR INVERTER OFF! J . .._ __ u i Safety Output VOL'aEe Per Power D_pNmr:er f Vole Q J I(lx 0) STANDARD COMPLIANCE EMC FCC P n15 Class B,1EC61000 6 2,IEC61000 6 3 I»•D�Ecr xunlaE... ' Safety IFCG2109-1(class it safety),u11741 I OP-00149111 Material L)L.94(5-VA).DIV Resistant ererexl ate: RoHS_ ----___ yes 9.50KW PV INSTALLATIONSPECIF CATIONS- _ ------_ --- ___ ..__-- IbidET nRE: Maximum A6oweJ System Voltage_ -_ --� _-�- — ---- —low Vdc POWER Dimensions X.x H) 143.210.4S/S.63 x 8.26 x 1.75 mrn/in OPTIMIZER Weigh 4SO/1.0 grllb SPECIFICATIONS Input Connector MC4/Tvco/H+5/Ampherol-H,1 CHIEF ElEcnaceN Output Wire Type Double insulated:6mm':MCA JASON ATKINSON Output Wire Length 0.95/3 0 0.95/3 0 I 1.2/3-9 1.6/5.25 m/it uaP.ogGCRxwreanmiRxcrx� r Operahng Tempeiature Range 40 +65/ 40 .l S0 - �c/T (310) 560-3297 Pro,e(Fou Rating IP65/NFMA4 Signature-Jason At wean Relative Humidity D-100 °/P LICENSE C10MA6#941069 PV 1 I V SYSTEM RTER DEIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V �! PV power optimization at the module-level Mip;q,W1»String ength lPpwer Optimize=sl 8 B 18 1� aximu ,String ungm fPOwel Optimizers) 25 25 1 50 Up to 25%more energy Maxima ,Power per 5tnng 5250 6000 IN50 4V �. Superior effid2rucy(99.5%) ,t Parallel rings of 0ifterem LPngtfis pr Orirntallons YDs American Coy ReA.In/issu.1 oux, Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Solar Direct AS BUILT2 1a naRaon. A9 Flexible systen design for maximum space vdlira6nn cA LIOERSE et,olc4o xa4,B4v BNLT AB CC IOWA Next generation maintenance With module-Itvel monitoring AS BUILT °" Module-level 7oliage shutdown for installer and Hrefightes safely BRAxlxaewrA•oExTxuAaoe axcrroarem xmruxaox CAD Raivi.i.. Wn111 YAMBmgrNTm BY NERN/N BCURtlRECr WG NJ CGNSiAVCI1ON M'DANY PADCFDVRFS SfW1CgiNRM FMT KTM9p.QaEMeTp BE WI'In APPIJCABLE NEC AND aULLDP'G CGDES.GRW W/ygpppOVFD BB0.0am TD(RNEPa Mnpll! S ETSIlA1.L DILTAik PRDefIS SLOPE DF gORx irE PPopRYMni61 FE11x6Vx1 OP NIHU%YBpMOPCCr MC. .. ,.. l`dV.'Le i 11 Yia• PERMIT NO Rer PERnRr�mngmTe JEC-CAF1422A4 zs.r4 HP/PS/04/M14 aEQ RY/APPROVAL DAre — JEC-JZ/AB/6.16.14 JZ-MCC-8/5114 OPTIMIZER SPECIFICATION 5nea GSl City of Menifee Permit No.: PMT14-00990 29714 HAUN RD. Type: Residential Electrical /�-lCG�7J4�-. MENIFEE, CA 92586 MENIFEE Date Issued: 08/26/2014 PERMIT Site Address: 29788 TIERRA SHORES LN, MENIFEE, Parcel Number: 340-500-010 CA 92584 Construction Cost: $47.500.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR PV SYSTEM, 38 MODULES,2 INVERTERS,9.5l Work: Owner Contractor MARY&DAVID BILLINGS AMERICAN SOLAR DIRECT INC 29788 TIERRA SHORES LANE 11766 WILSHIRE BLVD STE 500 MENIFEE, CA 92584 LOS ANGELES, CA 90025 Applicant Phone:4242146700 AMERICAN SOLAR DIRECT INC License Number: 941069 217 N SUNSET AVE CITY OF INDUSTRY, CA 91744 Fee Description Qy Amount 1$) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 Additional Plan Review Electrical 113 112.50 Additional Plan Review Electrical 129 129.07 Additional Plan Review Electrical 129 129.07 GREEN FEE 1 2.00 SMIP.RESIDENTIAL 1 5.00 $656.64 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ I, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and my license is in full force and effect. Code:The Contrador's License Law does not apply to an owner of a property License Class License No. who builds or improves thereon, and who contracts for the projects with a Expires Signature licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ lam exempt from licensure under the Contractors'State License Law for the ❑ I hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Labor Code, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that 1 have permit is issued. built as an owner-building if it has not been constructed in its entirety by licensed Policy# contractors. I understand that a copy of the applicable law, Section 7044 of the ❑ 1 have and will maintain workers compensation insurance, as required by Business and Professions Code,is available upon request when this application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:htto'//www Iecinfo ca oov/calaw htm1.. permit is issued.My workers'compensation insurance carrier and policy number are: Property corer or Authorized Agent Date Carrier Expires Policy# ❑ By my Signature below, I certify to each of the following: I am the property Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit Is for application and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and stale laws relating to building construction.I authorize representatives of this city or county to enter the above- 0 1 certify that in the performance of the work for which this permit is issued,I identified property for the inspection purposes. shall not employ any persons in any manner so as to become subject to the workers'compensation laws of California, and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Property Owner or Authorized Agent Date Code,I shall forthwith comply with those provisions. City Business License# Date; Applicant; WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, OYES OCCUPANT HANDLE A HAZARDOUS MATERIAL ORA DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES ❑NO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS INFORMATION GUIDE? I hereby affirm that under the penalty of perjury there is a construction lending agency for the performance of the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE Lender's Name DYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION FROM THE SOUTH COAST AIR QUALITY MANAGEMENT Lender's Address ❑NO DISTRICT(SCAQMD)SEE PERMITTING CHECKLIST FOR GUIDE LINES OWNER BUILDER DECLARATIONS PRI NAME:• 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the reason(s)indicated below by the checkmark(s)I have placed OYES )NIL POSED I�I�G OR MODIFIED FACILITY next to the applicable item(s)(Section 7031.5.Business and Professions Code: B L ( T OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, ❑NO SCHOOL. or repair any structure, prior to its issuance, also requires the applicant for the 3 permit to file a signed statement that he or she is licensed pursuant to the ' -.x provisions of the Contractor's State License Law (Chapter 9 (commencing with I HAVE READ TFi'E.�i HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or DYES INFORMATION GUIDE AND 'fHE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY a civil penalty of not more than($500).) CODE, SECTIONOUS 25505RIALf�E 5533 AND 25534 CONCERNING HAZAR❑ I, as owner of the property, or my employees with wages as their sole compensation,will do( ) all of or( )porting of the work, and the structure is PROPERTY OWNER OR AUTHORIZED AGENT not intended or offered for sale.(Section 7044,Business and Professions Code; X The Contractor's State License Law does not apply to an owner of a property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion,the Owner- Builder will have the burden of proving that it was not built or Improved for the purpose of sale). EsGil Corporation In Partnership with Government for Buirding Safety DATE: 08/20/14 El APPLICANT ❑ JURIS. JURISDICTION: Menifee ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: pmt14-0990 SET: Revision I, Set II PROJECT ADDRESS: 29788 Tierra Shores Road PROJECT NAME: Billings 8800 Watt (5000 + 3800) Solar Photovoltaic Systems ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person E-mail: ® REMARKS: Revision to single line diagram, deletion of junction box and grounding modification. By: Eric Jensen Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ PC 08112 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax(858)560-1576