PMT14-00927
City of Menifee Permit No.: PMT14-00927 29714 HAUN RD,MENIFEE, CA 92586 Type: Residential Electrical ' iGC1.%4 MENIFEE Date Issued: 05/12/2014 PERMIT Slte Address: 29081 NECTARINE ST, MENIFEE, CA Parcel Number: 333-621-005 92584 Construction Cost: $9,593.40 Existing Use: Proposed Use: Description of INSTALL RESIDENTIAL ROOF MOUNTED SOLAR PV SYSTEM Work: 14 MODULES 14 MICROINVERTERS 3.57KW MASTER PLAN CHECK PMT14-00706 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR STE 302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone: 9493498000 AMY WILLIAMS License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description (�yt Amount f$1 's �. a wm� �!'^n �. J�q' ryry F'.'^'ip 'n.-+ax*" � � E-}'1°K".�'6{' o• °ry Building Permit Issuance 1 27.00 aG�REEN F��E� F� •' i�',E��.i .aF '" ' �`a�� � atc����� u3�i��.,�. - ,pa�,,' � 0'` SMIP RESIDENTIAL 1 1.00 $281.00 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 }� ( E �g�['Y OFiVl�iNIF�i PLCK No: Mc;4 29714 Haun Road Date: Oat,:Menifee, CA 92586 � � Phone: (951)672-6777 Am00°`' °ud�� 00 Fax:(951)679-3843 Building Combination Permit ��G To Be Completed By Applicant Legal Description: Menifee Hills/El Dorado Plann ng Case: F; L: Rt: R Property Address: -" eseor's PgcgNpr�rbar. �Sr T31582-1 Loth ` J Projec7Tenant Namr31852-1 El Dorado lunit#: Floor#: Name:Lennar Homes of California,Inc. Phone No.951.207.3045 Fax No. Property Address: Unit Number Zip Code 1 Owner 980 Montecito Drive,Suite 302 Corona 92879 Email Address: j. Nama:AmyWilliams Phone No.951.207.3045 Fax No. Applicant Address:Same as above Unit Number Zip Code . Small ddresa: amy.Williams@lennar,COM I; Name: Phone No. Fax No. �.. Contractor Address: - city State Zip Code i Contractors City Business License o. Cont 72810cly State or California License No. Classification: B Number of Squares: _ ]' Square Footage Description of Work: /� �/�/ Cost of Wark:$ S" Date: Applloant's Signature G To IBa Completed By City Staff Only O 1 nil cabe As R-Received or N/A-Not Applicable 5 Completes sets at fully dimensioned,drawn to sale plans which include: 1 set of documents which include ❑ Tide Sheet ❑ Elevalions ❑ Electrical Plan ❑ Gee Tech/Solis Report(on ad only) ❑ Plotl Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8%x 11) ❑ Structural Calculations ❑ Foundation Plan ❑ Cross Section ❑ Plumbing Plan ❑ Single Line diagram for alec.services over 400 AMP ❑ Floor Plan ❑ Stlucluml Framing Plan&Details ❑ Sharing Plan ❑ Sound Report-Resideptlai Class Code: Indicate LJNFwConstructlon Alteration' Addition' MeanslMethods Work Type: Repair" - Retrofit* ReAslon to Exisgng Permit'Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: #Units: If Storles: Will the Building Have a Basement? Y of N Bldg.Code Occupancy Group Indicate it Indicate all Geo-tech.Haz.Zone At Project Indicate Sprinklers d YES or NO That apply: Coastal Zone Construction Completion: Type(s): Coro YES or NO Noise Zone Requireda Used on Historic Resources Inventory r:ITY PLANNING STAFF ONLY APPROVALS: Costal Commiss Arch.Review Board Landmark Comm. Planning Comm.Zoning Administrator Fee Exempt: City Project Eton.Vehicle Charger Landmark SBlsttlle Retrofit oifdaalA dSB�el °' Expedite Project(s): Child Care 'try Project Green Building ILandmarill lAffordable Housing For Staff Use Only Building/Safely IPermit SpecialistI City Planning I n Transportation Mgmt. Rcnl Control _ THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFRV ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE LOCATIONS INDICATED BY THE ILLUSTRATION. SYSTEM SIZE 3.57KW MODULE 14 PCS. BEN -24/88-9 BUYER:________------- - INVERTER 14 PCS. ENP -ZLL-522-IG ROOF TYPE TILE W/COMPONDER ARRAY DATE:---------—----—---_------------- - SUB-ARRAY INFORMATION ARRAY#I ARRAYMOD CITY I4 NA BUYER:_—_______________—_______TILT23NA' DATE:____—___---------- AZIMUTH 221- NA' NA' V'C V1' UTILITY METER 8 MAIN SERVICE PANEL T —- - I r - VERIFIED BY BUILDER) I I PV AC DISCONNECT EXTERIOR-GARAGE 1 I ' SOLADECK WIRE TRANSITION BOX ' (UNDER ARRAY) I � I 71 23'-&2�ARRAY Ldl.,.,D._ARRAY CITY OF MENIFEE II'-10" 2r/-I}-FLASHING 5'-FLASHING BUILDING AND SAFETY DEPA PLAN APPROVAL REVIEWED BY NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 3105 ELEVATION B of these A 11 not Construed to ORIENTATION 4 LDr#5 ,.- d,,r. any p visionsoftlle ORIGINAL BY: TOM FIDDES OATE:14.03.31 'Iy,,�ut of approved SUMMIT AT LENNAR: REVIEWED BY:STACEY MCKINNEY DATE:14,03-31 980 MONTECITO DRIVE REV.# RY DATE DESCRIPTION MENIFEE HILLS CORONA,CA92789 �ungMaste DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Brw&ay Street INDIVIDUAL 29081 NECTARINE STREET Bodder,CO 80304 PLOT PLAN /Ib'=I'-0' MENIFEE,CA 305.447.0300 SYSTEM LAYOUT 10 i � > +' N PLAN 31D5 ELEVATION O ORIENTATION 4 LO1#5 ORIGINAL BY. TOM TIMES DATE:14.03.31 LENNAR: SUMMIT AT REVIEWED BY:STACEY MCKINNEY DATE:14.03.31 900 MONTECITO DRIVE —REV BY GATE DESCRIPTION MENIFEE HILLS CORONA,CA92789 Vnamas'06 vor�v DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broaeway Street INDIVIDUAL 29001 NECTARINE STREET B..W.r.C000004 PLOP PLAN 2 V64'4-V MENIFEE,CA 303.447.0300 SITE PLAN I MODULE SPECS AND CALCULATIONS INVERTER SPECSAND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE 7 CALC UNIT I DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC IENPHASE TEMP.AMBIENT HIGH(Tnax) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215.60-21-L-S22-I13 TEMP.AMBIENT LOW(THIN) ASHRAH EXTR.MIN •C -2 INV.MAX POWER.(WPC MA%) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTesi) MODULE SPEC °L 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(oc) 48 TEMP.[ LOW(TDELTA) TwM-Treu •C -27 INV.OUTPUT V.(VA[NOhD INVERTER SPEC VOLTS(ac) 240 MOO.MANUFACTURER MODULE SPEC RENESOLA INV.OUTPUT FRE DUE NCY INVERTER SPEC HERTZ GO MOD.PART NUMBER MODULE SPEC JC255S-74189-e INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AO 0.9 MOD.POWER SIC(P) MODULE SPEC WATTS(Do) 255 INV,PHASE QUANTITY INVERTER SPEC PHASE I MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(UD) 30.20 COMPLIANCE INVERTER SPEC ULI741/IEEEI547 MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(06 37.60 INV.GROUNDING INVERTER SPEC ISOLATED MOD.COEFF.VOLT/TEMP(CJ6T) MODULE SPEC VYC -0.1❑ INV.QTY,MAX/BRANCH CCT. IW Yet OTY 14 M00.MAX VOLTAGE(Naaxn00) (V0c (To'CDBFD VOLTS(oQ 17076 BRANCH CCT.OUTPUT.IMAXBC (IAC'INV.OTYOU AMPS(AC) 12.60 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 0.44 INV.QUANTITY,TOTAL INV.OTYr OTY IL MOD.SHORT CCT.CURRENT(USG) MODULE SPEC AMPS(OC) 8.99 TOTAL SYSTEM OUTPUT.IHnzrs (bAC 1NVATYq AMPS(AU 12.60 MOD.MAXIMUM CURRENT(IMAX) (Isc•625) AMPS(DC) 1124 MIN.AMPACITY REO'0,PER NEC (IMAX•1.25) AMPS(DU 14.05 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DcI 20 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY*MANUFACTURER MODEL NOTES TRADE OESOLA JC255S-2L/88-e PV MODULESOLAR 14ASE M213-60-2LL-S22-IG PV INVERTER SOLAR 3 1 /SOLADECK 0706-3R5 PV ROOF JUNCTION BOX,NEMA 3RSOLAR 4 1ER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 I TBD Tp0 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TOO PV BREAKER,I x 20A-2P,LO TE AT OPPOSITE END OF BUS FIRM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN.125A BUS BLDR.ELEC. II 1 TOD TBD UTILITY METER.IPH.120/24OV.200A BLDR.ELEC. I2. TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): (AMPAU7Y•TEMP.DERA7E'fILL DEBATE) .REO'0(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPAW I T AT TERMINALS. YL REQ'D.(IMAX•1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE [U/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REO'0 OCO p115 RATING AMPS 200 TYPE DEBATES DERATE DEBATE (A) (Al USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 .76 1.0 22.80 12,60 ALLOWED PV PER NEC AMPS 40 TERM 25 25 15.75 20 PV OCPD DEVICE USED AMPS 1 20 B #10 CU NM-B COU 40 .91 Lo 36.40 12,60 TERM 35 35 IS.75 20 C #10 CU NM-B COU 40 .91 TO 36,40 12.60 TERM 35 35 15.75 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE.I-#6G.FREE AIR I CU TL-ER I ARRAY SOLAR B 3-viol I-#10 EGC N NM-B(BONE%) INTERIOR SOLAR C 3-#10.I-#10 EGC CU NM-B(BONE%) INTERIOR SOLAR D CAiSE.ETHERNET CABLE CU CATSB INTERIOR SOLAR II 6 5 D ® •o RT ENT SEE 10 NOTE 20 O© I 9 Q 0 Or 2 u' o 3 A I DA 12 EXTERIOR-GARAGE ROOF H 3 I iermit for,or aI ELECTRICAL DIAGRAM 3.57KW eder,I,state or city LOT#5 ust be kept m LENNAR: SUMMIT AT ORIGINAL BY: TOM FIDDES DATE:I .03.31 REVIEWED BY:STACEY MCKINNEV IDATE:14.03.31 980 MONTECITO DRIVE REV.# BY DATE DESCRIPTION MENIFEE HILLS CORONA,CA 92789 S ti namas A IOIAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4511 Bmrt xay Street INDIVIDUAL 29081 NECTARINE STREET Boulder,CO B0304 PLOT PLAN 3 NTS MENIFEE,CA =T447.0300 ELECTRICAL T�R}fTURAI NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(T)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SMALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO HE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, 1.)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO HE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SMALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT MAY BE ELECTRICALLY INSULATEAL PARTS D BECAUSE HALL BE OF PAINT/FINISH. PAIN IECKED FOR FIN SH AER T POINT OF CONTACT SHALTING T14AT L BE PROPERLY REMOVED. ENCLOSURE'S FINISHED SURFACE 5)ROOF PENETRATIONS WILL HE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENT& 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL HE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPMASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIXE MANNER. SIGNAGE- I2)PV SYSTEMS SMALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 13)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 14)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT T;'. 15)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EOUIVALENTI WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL CONTRACTOR- 16)INSTALLATION SHALL BE COMPLETED IN d NEAT AND WORKMAN-LINE MANNER. 17)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE U0.26. IN EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250,122, 19)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 20)A DEDICATED 12OV BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET FOR ENPHASE ENVOY MONITOR. ORIGINAL BY: TOM FIDDF.S DATE:14.03.31 SUMMIT AT LENNAR: REVIEWED BY:STACEY MCKINNEY DATE:14.03.31 980 MONTECITO DRIVE REV.# BY DATE DESCRIPTION MENIFEE HILLS CORONA,A92789 unamaste DWG TITLE: PAGE#o SCALE: SITE LOCATION: 4571 B.a SY Street INDIVIDUAL 29081 NECTARINE STREET Bo303.4 TOGOOCO 4 PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM, DISCONNECTS ARE LOCATED AS SHOWN. UTILITY IIETER B MAIN SERVICE PANEL (VERIFIED BY RIIILDER) PV AC DISCONNECT EXTERIOR-GARAGE SOLADECtt WIRE TRANSITION ROX (UNDER ARRAY) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR AA vA NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION re ORIGINAL RY. TOM FIBRES DATE:R,03.3 SUMMIT AT LENNAR 1 : REVIEWED BY:STACEY IICKINNEY DATE 1A.03.31 980 MONTECITO DRIVE REV.# BY DATE DESCRIPTION •f MENIFEE HILLS CORONA.CA92739 unamasGB OIA• DWG TITLE: PAGE #-. SCALE, SITE LOCATION: 4571 BroaAvay Street INDIVIDUAL 29081 NECTARINE STREET Boulder.CO 80304 PLOT PLAN NiG IIENIFEE,CA 303.44Z0300 PLACARDS