Loading...
PMT14-00852 City of Menifee Permit No.: PMT14-00852 29714 HAUN RD. Type: Residential Electrical 49�CCELt - MENIFEE, CA 92586 MENIFEE Date Issued: 05/2912014 PERMIT Site Address: 31065 SADDLEBACK LN, MENIFEE, CA Parcel Number: 360-210-007 92584 Construction Cost: $24,750.00 Existing Use: Proposed Use: Description of GROUND MOUNT SOLAR-22 PV PANELS- 1 INVERTER-5.5 KW Work: Owner Contractor STEVE MCCRIGHT PRECIS DEVELOPMENT INC 31065 SADDLEBACK LN 36625 KEVIN RD STE 147 WILDOMAR, CA 92595 Applicant Phone: 9516969400 ' STEVE GUSCHING License Number: 952305 PRECIS DEVELOPMENT INC 36625 KEVIN RD STE 147 WILDOMAR, CA 92595 Fee Description Ott Amount ISI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 Additional Plan Review Electrical 129 129.07 Additional Plan Review Electrical 129 129.07 _ Additional Plan Review Electrical 129 129.07 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 3.00 $670.21 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION I hereby affirm under penalty or perjury that I am licensed under provisions of ❑ 1, as owner of the property an exclusively contracting with licensed Chapter 9(commencing with section 7000)of Division 3 of the Business and contractors to construct the project(Section 7044, Business and Professions Professions Code and my license is in full force and effect. Code:The Contractor's License Law does not apply to an owner of a property License Class }3 License No.95Z30 s who builds or improves thereon, and who contracts for the projects with a Expires 9-3n-ry Signature_,,S4;;4;L licensed contractor(s)pursuant to the Contractors State License Law). WORKERS'COMPENSATION DECLARATION ❑ lam exempt from licensure under the Contractors'State License Law for the ❑ 1 hereby affirm under penalty of perjury one of the following declarations: following reason: I have and will maintain a certificate of consent of self-insure for workers' By my signature below I acknowledge that, except for my personal residence in compensation,issued by the Director of Industrial Relations as provided for by which I must have resided for at least one year prior to completion of Section 3700 of the Labor Cade, for the performance of work for which this improvements covered by this permit, I cannot legally sell a structure that I have permit is issued. built as an owner-building if it has not been constructed in its entirety by licensed Policy# contractors. I understand that a copy of the applicable law, Section 7044 of the It I have and will maintain workers' compensation insurance, as required by Business and Professions Code,is available upon request when this application is section 3700 of the Labor Code, for the performance of the work for which this submitted or at the following Web site:hHp'//www leoinfo ce gov/calaw html. permit is issued.My workers'compensation insurance carrier and policy number are: �o Property Owner or Authorized Agent Date Carrierc�?TA rc_ ,-��F.�sar,,.� ins�¢atiw r;,,��. Expires;-%i.-%S Policy# 90H 537'/ ,�I By my Signature below, I certify to each of the following: I am the property Name of Agent Phone# owner or authorized to act on the property owner's behalf. I have read this (This section need not be completed if the permit is for application and the information I have provided is correct. I agree to comply one-hundred dollars($100)or less) with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to enter the above- 0 1 certify that in the performance of the work for which this permit is issued,I identified pr arty for the inspection purposes. shall not employ any persons in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers'compensation provisions of Section 3700 of the Labor Property Owner or Authorized Agent Date Code, I shall forthwith comply with those provisions. City Business License# Date; Applicant; WARNING: FAILURE TO SECURE WORKERS' HAZARDOUS MATERIAL DECLARATION COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS WILL THE APPLICANT OR FUTURE BUILDING ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DYES OCCUPANT HANDLE A HAZARDOUS MATERIAL OR A DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE MIXTURE CONTAINING A HAZARDOUS MATERIAL LABOR CODE, INTEREST,AND ATTORNEYS FEES Ig NO EQUAL TO OR GREATER THAN THE AMOUNTS CONSTRUCTION LENDING AGENCY SPECIFIED ON THE HAZARDOUS MATERIALS I hereby affirm that under the penalty of perjury there is a construction lending INFORMATION GUIDE? agency for the performance of the work which this permit is issued (Section WILL THE INTENDED USE OF THE BUILDING BY THE 3097 Civil Code) APPLICANT OR FUTURE BUILDING OCCUPANT REQUIRE Lender's Name OYES A PERMIT FOR THE CONSTRUCTION OR MODIFICATION FROM THE SOUTH COAST AIR QUALITY MANAGEMENT Lender's Address NO DISTRICT(SCAQMD) SEE PERMITTING CHECKLIST FOR GUIDE LINES OWNER BUILDER DECLARATIONS I hereby affirm under penalty of perjury that I am exempt from the Contractor's PRINT NAME: License Law for the reason(s)indicated below by the checkmark(s)I have placed OYES WILL THE PROPOSED BUILDING OR MODIFIED FACILITY next to the applicable item(s)(Section 7031.5. Business and Professions Code: BE WITHIN 1000 FEET OF THE OUTER BOUNDARY OF A Any city or county that requires a permit to construct, alter, improve, demolish, p/7 NO SCHOOL? or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with I HAVE READ THE HAZARDOUS MATERIAL Section 7000)of Division 3 of the Business and Professions Code)or that he or [t YES INFORMATION GUIDE AND THE SCAQMD PERMITTING she is exempt from licensure and the basis for the alleged exemption. Any CHECKLIST. I UNDERSTAND MY REQUIREMENTS violation of Section 7031.5 by any Applicant for a permit subjects the applicant to ❑NO UNDER THE STATE OF CALIFORNIA HEALTH AND SAFETY a civil penalty of not more than($500).) HAOZDAEDOUSTMATERIALSf�EPOR�ING D 25534 CONCERNING ❑ 1, as owner of the property, or my employees with wages as their sole compensation,will do( )all of or( ) porting of the work, and the structure is PR P TY OW -OR AUT ORIZED AGENT not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property X who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the Owner- Builder will have the burden of proving that it was not built or improved for the purpose of sale). CITY IOF MENIFEE PLCKNo: Permit No: 29714 Haun Road City of Menifee )ttlT K gSZ Building & safetyDept. Date: Ogle: 1 Menifee, CA 92586 - - ty 21'b� Phone: (951)672-6777 APR 16 2014 Anne °W1q 3 AToUnt g Z "1 Fax:(951)679-3843 Ck#; Ck#: Received � ��� Building Combination Permit S 3 To Be Completed By Applicant Legal Description: PlanningCase: F: L; Rt: R; Property Address: Assessor's Parcel Number. 31 5 SAIDpLE C34Ck L Ai — b - __ Prot Name: 5l"EV E McCL?I C'7 o-lf Unit#: Floor#: Name: Phone No. S T kV F r Fax No. Property Address: - $1-70 - Owner 3i 0 6 S SfFn/O t- C l/3,4 C/-- Unit Number Zip Code Email Address: Name: nJTFVFN U sc,4 n. (7 Phone No. Fax No- Applicant Applicant Address: n �-m z7 Unit Number Zip Cade Email Address:Si //'<UrcG r£LISsec-rnr( ,C>e.rt Name: I� Phone No. Fax No.' ��a� `1,)-lv°�lo`%Vln Contractor Address: 3Cdn25- lcww PF /Y-7 City State Zip Coda R W MML C� zvI5 Contractors city Business License No. Contractor's City State of California License No. SZ 3n� Classificd<ipn: Number of Squares: .i� Square Footage Description of Work: //�� �6(s+J1J Wl-6 U/J7' $6L-ate. 2Z P�f PA+JELS ``� �vJ Cost of Work:$1a Applicant's Signature 2�15D pD Date: 777777777 "_'` To Be Completed By;Clty'Staff Only - Indica',e As R-Received or N/A Not Applicable 5 Completes sets of fully dimensioned,drawn to sale plans which -cf de: 1 set of documents wh¢h include ❑ Title Sheet ❑ Elevations ❑ Electrical Plan ❑ Gee Tech/Soils Report(on cd only) ❑ Plot/Site Plan ❑ Roof Plan ❑ Mechanical Plan ❑ Title 24 Energy(on 8 '/,x 11) ❑ Foundation Plan ❑ Cross Section ❑ Plumbing Plan ❑ Structural Calculations ❑ Single Line diagram for elec.services over 400 AMP ❑ Floor Plan ❑ Structural Framing Plan&Details ❑ Shoring Plan ❑ Sound Report-Residential Class Code; Indicate New Construction Alteration* [Addition- Meansrhlethods Work Type:HRepair' Retrofit' Revision to Existing Psrmjl' Required? YES NO Proposed Building Use(s): Existing Building Use(s): #Buildings: q Units: #Stories: Will Ole Building Have a Basement? Bldg. Code Occupancy Group Y of NIndicate if Indicate Indicate all Geo-tech.liaz.Zone At Project Sprinklered YES or NO Completion: Construction that apply: Coastal Zone Type(s): C Of O NO Noise,Zone YES or Required? Listed on Historic Resources Inventory CITY PLANNING STAFF ONLY APPROVALS: Costal Commiss Arch.Review Board Landmark Comm. Planning Comm.Zoning Administrator Fee Exempt City Project Elec.Vehicle Charger landmark Seismic Retrofit 'pacial Casa'slog Of/cial Aocmval Expedite Projecl(s): Child Care City Project Green Building Landmark Affordable Hcusing For Sta it Use Only Buildinq!Salely Pumi•i Specialist City Planning qnl Erginaen ng I -Admht Tmnsporlalion i4lgmt. I Rcr,l Contra) THANK YOU FOR HELPING US CREATE A BETTER COMMUNITY McCright 5 . 5 kWpDC00 ��'� pE MEt~gyp SPFE'(� OEQPaSM n1NG P v hotovoltaic Systems tre} Y °v �� O) P U) � U') , y emf'tc "�xa c Q p M y� Y a�yexr �acc»av ? U � VICINITY MAP slue"`} e Y (aR ��' Ern = o LO O � C Z C0 i fU N t s ; rt of J �. � PROJECT ,�m^°rocoa. un n Menifee em,.W OCATION N111. d r A bU. Lyd In � M ruir�a lobo.He '1 _- 9 i 8 awrs,is.c y3 i r m A vmyc.,am 5 .� zY izae,, C 00 J � GENERAL NOTES: a° o s s n.�eew.r s.n.:in Se s „tea 1. The California Residential Code (CRC) requires that Smoke Alarms `J �p and Carbon Monoxide Alarms are retrofitted into the existing dwelling. LO C.) to The required Smoke Alarms and Carbon Monoxide Detectors shall be Lr) located as required per sections R314 & R315 within the California p Residential Code (CRC). co Designer Signa ur CUSTOMER: CONTRACTOR: SHEET SHEET DESCRIPTION City OfMenifee Steve McCright Building & Safety past MAY 2 i _ 31065 Saddleback Lane PRECIS SOLAR T-1 TITLE SHEET Menifee CA 92584 36625 Kevin Rd. St. 147 / 148 Wildomar CA 92595 PV-1 SITE / ROOF PLAN Receive`951 -704-5661 951-696-9400 APN# 360-210-007-7 Lic. No. 952305 PV-2 MOUNTING DETAIL, Title: TITLE SHEET WIRE & CONDUIT CHART Project - Lot: B Date: 3-11-14 Parcel: 10884 PV-3 ELECTRICAL SINGLE LINE Sheet: T-1 Scale: NTS 00 *A CLEAR BRUSH AREA OFTEN FEET(10') IS REQUIRED AROUND THE PERIMETER OF GROUND MOUNTED PHOTOVOLTAIC ARRAYS. KEY NOTES *DO NOT EXPOSE THE INVERTER TO DIRECT SUNLIGHT. 1. PROPOSED 225AMP PANEL ti 2. PROPOSED LOCATION OF ITRON PRODUCTION METER 3. PROPOSED LOCATION OF AC DISCONNECTS 6 4. PROPOSED LOCATION OF(1)SMASB5000US INVERTER WITH INTEGRATED DISCONNECT U) 0-) 3 5. PROPOSED LOCATION OF CONDUIT(BURIAL DEPTH 18")XFER N TO EMT UP THE SIDE OF THE HOME AND ACCROSS ROOF. O7 -0 O 6. PROPOSED LOCATION OF GROUND MOUNTED (22) E250 SOLAR Q O. 00 M 4 MODULES WITH TOTAL AREA=396 S.F. U CV > L 0) a LO m YErn 2p 5 N 0 (0 , cZ m m GENERAL NOTES M J — - — - — - — - — - — - — - — - — - — - — - — - — - — 1. KEY MANUFACTURERS ARE: I — - — - — - — - - —�— - — - — — - — - — - — -MODULES,CENTROSOLAR \ -' E>Xti e��.• 42273 FREMONT BLVD. 'Qw I ® I FREMONT,CA 94538 -+ -INVERTER,SMA SOLAR TECHNOLOGIES 4031 ALVIS CT IfJ� ROCKLIN,CA 95677 C -RACKING,UNIRAC, INC.(OR EQUAL) wVw, _.1 1411 BROADWAY BVD, NE W Burial Depth 18"Minimum/- (.5 ALBUQUERQUE. NM 87102 \ Schedule 40 PVC I m 2. ALL COMPONENTS ARE ILL LISTED AND CEC CERTIFIED, WHERE 100'-155'Distance WARRANTED. 3. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE 2010 CEC,AND 2010 CBC. J V POOL EMT EXISTING m 4. ONLY (1) 225A SERVICE ENTRANCE, (1) 30A UTILITY VISIBLE AC -1--r U LO -- -- --�-- -- -- - �,F.D. EXISTING (A DISCONNECT FOR UTILITY OPERATIONS. � 77•-•�� tE (N DRIVEWAY 5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED •v, 0) Q INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR L 7 U CIRCUIT"EVERY 5 FEET. 70 U 6. A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY � U (n ACCESSIBLE LOCATION EITHER OUTSIDE OF A BUILDING OR STRUCTURE L I OR INSIDE NEAREST THE POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS AS PER SECTION 690-14 OF THE CEC. I 7. HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6' -7"'PER NEC 240.24 I 8. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC L — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — — — — — J 690-47 AND 250-50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER Designer Signature CEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE - USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE, A SUPPLEMENTAL i r GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION ,. 2 1 CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8AWG AND NO GREATER THAN #6AWG COPPER AND BONDED TO THE -- EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4 9.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. - - _ -- 10.PER SECTION R314 AND R315 OF CRC 2010,ITS REQUIRED THAT SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED Propose INTO THE EXISTING DWELLING FORA PERMIT WITH REPAIRS Title: SITE PLAN OR ADDITIONS EXCEEDING$1000.00 Project#: - Array N 11,WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL Date: ' EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE IN 3-11-14 - - ACCORDANCE WITH NEC 110,26. 12.ADEQUATE SPACING SHALL BE MAINTAINED BETWEEN ANY Sheet: PLUMBING SEWER VENTS EXTENDING THROUGH THE ROOFAND THE UNDERSIDE OF THE PHOTOVOLTAIC PANELS �\v,� 13.WHERE DC CONDUCTORS ARE RUN INSIDE THE BUILDING(OR ATTIC), SCALE: THEY SHALL BE CONTAINED IN A METAL RACEWAY.(NEC 690.31 E) SITE ROOF PLAN NTs 1 Scale: NTS 00 GROUND MOUNT NOTES 1. Pro Solar Racking System, or equal E250 Sala Pentls r 2. Mounted in 1 group totaling 22 Modules +: Ln TOP VIEW OF PV ARRAY,TYPICAL OF ONE to M 3. See attached manufacturer spec's for -0 N — — — spacing and bolt size requirements � � �C) 0p M MAWGBARECOPPER Q Q O CO GROUND TRAC SUPPORT FRONT POSTS EXTENDAPPROXIMATELY CONDUCTOR •— U " N�I•� 12-W ABOVE GRADE.REAR POSTS > L0 CHANNEL LAID PERPENDICULAR - EXTEND APPROXIMATELYBO'BOVE OVER GALVANIZED PIPE. — ._ _._..._ _ 1 IYY'I.D.SCHWLE 40 GRADE.ENTIRE HEIGHTOF STRUCTURE Y LO O GALVANIZED PIPE.LAID EXISTING GRADE LO C = O SUPPORT CHANNEL SCORED TO C ACROSS POST TOPS AND - Dom" r -� +s ".P�J's GALVANIZED PIPE WITH � r rs. - V" STAINLESS TEEL U BOLTS.PV SECURED WITH HOLLAENDER L ( u .'� � Z PANELS ATTACHED SUPPORT — _— _ _ FITTINGS,OR EQUAL I IITIDSCHEDULE40 CHANNEL WITH MODULE CLAMP$. GALVANIZED PIPE.PLUMED j M1 UL LISTED SGAWNO ROD,WITH UI \ VERTICAL.47OF PIPE f LISTED ACORN NUT.BONDED TO W u/ •� U EMBEDDED IN CONCRETE 4 f E ARRAY,RACKING AND GROUNOING \ `' ELECTRODE AT SERVICE ENTRANCE 1 12•DIAMETERHOLETOBE POSTS ARE WRAPPEOWITH2O FILLED WI012500 PSI OR MIL TAPE ATTOPWHERE POST O BETTERCONCRETE EMERGEFROM CONCRETETO PREVENTCORPOSION 'w 6� TYPICAL MOUNT DETAILS NITSLE. 1 4 KEY NOTE 12" 61 11 „ 00 5 XO See Single Diagram sheet PV-3 0 U LO 18" Q L Q 7' 10 9/16" LO a MENIFEE TEMPERATURE L6 02 AVERAGE AMBIENT TEMPERATURE(F) 71 M MINIMUM HISTORICAL TEMPERATURE(F) 33 Designer Signature TEMPERATURE ADDER(F)310.15(13)(2)c 40 1 8" CLOSE UP POST SPACING WIRE RUNS, AMPERAGE, VOLTAGE DROP AND CONDUIT CHART WIRE RUN VOLTAGE ONE CURRENT CONDUCTORS GROUND AMPS AMPS MAX FUSE OR OPERARING MAX. DC/AC WAY DESIGN CITY. #IN AWG INSUL. CITY AWG WORST MAX W/NEC BREAKER (NORMAL) DIST. Vdrop(� PARALLEL CASE MINIMUM CONDUIT MULTIPLIER (AMPS) (FT) Vdrop MOUNTING DETAILS, ARRAYS TO JUNCTION BOX 8.76 13.68 15 303.40 340.98 DC 50 2% 2 2 10 PV 1 8 0.59% FREE AIR Title:WIRE CHART (XLPE) Project#: - JUNCTION BOX TOINVERTER 8.76 13.68 15 303.40 340.98 DC 50 2% 2 2 10 THWN 1 8 0.29% 3/4" MFC Date: 3-11-14 SB5000TL-US INVERTER TO POINT OF CONNECTION 21 26.25 30 211.0 264.0 AC 10 1% 3 1 8 THWN 1 8 0.84% 3/4" MFC Sheet: PV-2 SCALE: WIRE & CONDUIT CHART NTs 2I Scale: NTS - r1 KEY NOTE DO (22) MODULES: CENTROSOLAR E250B OX See Wire Run chart sheet PV-2 v (1 ) INVERTER: SMA SB5000-US-11 (240V) CONDUCTORS ARE 3#8AWG TWHN LO IN 1-(SCHEDULE 40 PVC)CONDUIT -0 OR LARGER AND GROUND I3#8 AWG THWN 0) 0 AC DISCONNECT CONDUIT TYPE CHANGES TO EMT Q O M �✓� SQUARE D DU221RB AT THE HOME. t_ U 'q 3 N (11)CENTROSOLAR E250 MODULES _ SWITCH NOT FUSIBLE > 0) LO GO 240V 30A 2P NEMI 0) UL LISTED OR EQUAL tB 'MOUNTED NEAR MAIN T (11)MODULES 2,750 WATTS STC E = 6 SERVICEPANEL CEC-PTC WATTAGE RATING In CONDUCTORS ARE 4#10 AWG (225.9)PER MODULE N t C Z CONDUCTORS ARE 3#8 AWG TWHN PV(XLPE)IN FREE AIR UNDER ARRAY (0 2_ N INa/a"CONDUIT OR LARGER AND AND GROUNDS ARE#6 AWG — Cr) PROPOSED 225A(PANEL)x 120%=270AAVVG BARE COPPER `Permit will be pulled by a licensed C-10 GROUND IS#8 THWN ) 200A(MAIN BREAKER)+30A(SOLAR)=230A (EMT) (11)CENTROSOLAR E250 MODULES ON COMPACT JUNCTION BO O O PULL UL LISTED OR (11)MODULES 2,750 WATTS STC ,w EQUALX I E CEC-PTC WATTAGE RATING r+ O //�\ (225.9)PER MODULE I/L 8 ton OF ON ,r V PV PRODUCTION METER i W OF ; 0 605.11 Solar photovoltaic power systentx.Soho plrolovul- AC DISCONNECT laic power system,shall be installed in acconhrnce with See- SQUARE D DU221 RB SMA SOLAR TECHNOLOGIES •( lints 605AIA through 605.11-4, tiro Califnniia Building GD 240 NO 2PNE A SMA SBSOOOU5240V MAN Code mid the California Electrical Cade. UL LISTED OR EQUAL CEC EFFICIENCY 96.8% QQ` to !ac , nml mu hedhabitable G U structures .r.. MOUNTED AT THE ARRAY PP p OUTPUT 240VAC @60Hz �� O�Q iu 1rmt limited to,parking shade,Wcares,car- J (max=30A _` a tit: trrllives and similar swnwrs siwll not be sots- Iq PROPOSED 30ACIRCUIT Inec=37.5A(Imax @ 125%) AVID N'w``N`` �C�� Q �r U 00 BREAKER TO BE CONDUCTORS ARE 3#8AWG TWHN CONDUCTORS IT ORL LARGER TWHN O� \'" O� ` '[ d '4luirealrnlS of this seeion. INSTALLED AT OPPOSITE IN 3/4"CONDUIT OR LARGER AND r` IN 8AWGTHWIN INTEGRATED DISCONNECT _` rl hury Markings required on interim and Q (6 END OF BUS BAR FROM — GROUND IS!!8AWG THWN GROUND IS #8AWG THWN �1 `_ SWITCH G� act vut-cunrm (I)CI cotxlvit. enclosures, race- �•�1 MAIN BREAKER T (EMT) (EMT) `` - G V. •v// w mG_F.r ���� ��� ways. cable aarmblies,junction boxes, wmbiner Iwxes L Q �x\` QQ� mid dixcpr(nlr ric U 1 Inverter(cd 21A Max output current x 1.25=26.25A V�_\ P .�4ptrfl'Jl.t Materials.rice nruterials used rite nuuking `` Ill sha{tr1( t] weather resistant and suitable for die U (D Q tpb¢ 1Fm�u���7Glarking as required in Sections �f J �N¢is ¢(6tn f�ll -through 605.11.1.4 shall have all letters cap- L vv Epp `1p¢ mied with a mbninanu height of/r inch (9.5 nun! LO SIGNAGE REQUIREMENTS S�attpo�b o�\s\oosotoJ¢aQ�aoS while on led background- PHOTOVOLTAIC �_ taps pyQt aQQI 605.11.1.2 Motidng content.The Rankin,shall con- CM ottb¢SeQ a�\oppt1I POWER the S%ordsE."WARNING: PHOTOVOLTAIC MAIN SERVICE oust S\J\ Q5� Ak r.F•QQl pfa� a\pant. 605.11.13 Main service dlstrumil f. The marking Designer Signature ON t '•l Q\pact S pa0\ `\p• shall be-placed adjacent to the main service discrannect AC r • i i t• r 8Q \pp a t¢ p in a location dearly visible from the location when the METER DISCONNECT WARNING t !r t r'r r t¢gUta� pp`\CplpQ disconnect is operated. ELECTRICAL SHOCK HAZARD.00 NOT t ¢ 605.11.1.4 Location of marldill Marking shall be TOUCH TERMINALS.TERMINALS ON ( t placed on interior Rid exterior DC Conduit.raceways, OFF ETH THE LINE AND ENERGIZED NTTHEOOFF(DES POSITION AY AS per 69D.35(P) y enclosures mill cable assemblies ever 10 rect (IOU min), within 1 fool (305 min)of turns or bends, and within 1 foot(305 icon)above and below penetrations WARNING of rrwf/ceiling accemblias walls or harries. -- THIS SERVICE METER IS ALSO SERVED -__ BY A PHOTOVOLTAIC SYSTEM t DISCONNECT CAUTION: IMPORTANT: - _ soLARCIRcmr PV POWER MAX AC OUTPUT OPFRAT ING CURRENTFF Make sure to measure the line-to-line and the line-to-neutral voltage of all service ELECTRICAL NOMINAL OPERATING AC VOLTAGE 2d0 VOLTS Sticker lxated every five reel on Title: SINGLE LINE RATE°DPERATINGDNRRENT 2,AMPS eooduits,ranewaYs.oabie entrance conductors prior to installing any solar equipment. ProjeDt#: - assemblies,at toms,above WARNING and/or below penetrations,all DC; Date: -- 10.95 .mbi,rc,,.ndLunononBoxas WIRE NUTS ARE NOT ALLOWED ANYWHERE IN THE PV SYSTEM PER INSTALLATION GUIDE 3-11-14 ' PHOTOVOLTAIC CONNECTION.DO NOT RELOCATE THIS OVERCURRENr OEM CE As per 690.53 J AND CEC SECTION 11 O.3[B]. SOLAR Sheet: '. 14.THE BACKFED PV BREAKER(S)AT THE MAIN PANEL WILL BE SYSTEM CAUTION PV BREAKER AS Per 705.10 "A Permanent plaque or directory, denoting all electric power sources INSTALLED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN IssxcKEo I On the remises, shall be installed at each service equip ment location and at PV-3 BREAKER AND A PERMANENT WARNING LABEL WITH THE FOLLOWING p q p MARKING WILL BE PROVIDED ADJACENT THE PV BREAKERS : sticker located next P.C.C. "WARNING-PHOTOVOLTAIC CONNECTIONN..DO NOT RELOCATE THIS ca inside service Panel locations of all electric power production sources capable of being interconnected." OVERCURRENT DEVICE.'•(NEC 690.64 B 7) Scale: NITS I CENTROSOLAR �y 1` �� • II • I �a City Safety Dept. guildin9 "� R 16 2014 - CENTROSOLAR; E-SERIES MODULE 60 CELL ReceiVed Engineered in Germany The Ce trosolar E Series PV modules are developed vvith the highest qualit f, r al �jmrrercial and residrrtial applications. Manufactured and tested undeF our s'rcte t quality .tan�r�di fN IS`a'�f�'��t9v6w,with field r�roven reliability and performance. ��J ,%?gg������ The Centrosolar E-Series modules engineered w with 60 polycrystalline high-efficiency si:,WceZN Wing higher power output per module- This configuration resuliS in reduced installation and balance-of-systern cost. RP �IVPd These mOdLfles have been designed to meet the performance and durability needs o" 'J, v e c y ions in North America - Including ice hail, sno"f, -storm, high humidity, and extreme thermal fluctuations. Neither heat no, cold can harm the Centrosolar E-Seres- It makes optimum use of available solar energy reliably, gemerahng hioh energy yields. Energy from High-Performance Products The Centrosolar E-Series modules are;available In dear or black anodized aluminum frames I-lieirarne is des,giied vv th water drainage holes and grounding holes on four sides and slotted mounting holes on long sides_ Modules are made with high quality materials Including top branded EVA and chernical resistant and flame retardant bark sheet and high-transparency lovv-iron loipact-resistant tempefed glass for lasting durability over the life of the product- UM QUALITY GUARANTEE ■ Pr?S;tib'i' [p`,"JPr ;Olerdn�E' l.' tC' -;b".,' ■ '10 year product workmanship vvxranty ■ Upto 25 year linear power•warranty of mininium peak power / rX ■ Proven ritu performance world id ■ F 1anu cui�eri to German quality and performance standards ■ Internal by-pass d'bde., across 20 series cells resists cffec-:s of shading ■ Passed 3'' party testing: Salt spray and Ammonia resistance ■ Conforms to UL 1703, ULC-ORL-C 1703-01 and CE con ipliant ■ !EC61215 safety tested to IF' 61730 .�GFNTROSOLAR • Model Typo E'<35 or E23513 E240 or E240B *'""E245 a E235E • leak Poe, V`datt; 235 240 245 2,50 Voltage at,MaNmus Power 29.S3 29.95 30 14 3v 114 Current at Maximum Power ditto 7 88 802 a 13 a 24 • Open 7 rcult Voltage(Voct 37^8 37.17 37 27 37.47 Shori Circuit Currant(scl SSo 873 2.76 i--rams Colcr Silver or EI tdenored by 6 at end of model N_Gp� ,,..rigs I ,,c 15 Maxrnum System Voltage 600V Temperature Cceffloerd(Pmaxi -9.y'19,,,! :. j Cjeperature CoeHicre VOID -0.308%b l"C Temperature C,r r an.f;scl B 023 C u.pat`able 412AWG.1 Conne00r eh ig T m 5 MC 4 Load eaeng 49U41- Weight Ins!kut 34 54.:13)1 CIlin mas;Teel-I GO cell,bl F61'"(156> .. NO'TTIaI Opere6ng Cell Temp.INW-1 �Fs1;T pludrsnO ,+ ,.aeln at •neck %%,1h I A, 1,a_—igeimenl bean. d,,,a 4 6 r D E F -, Did. H-Slot _ Inch T4.5 3906 3756 5.52 984 157 016 0 s5x035 _ :r6m i64If, 9W 95r1 140 250 40 14x9 t, HOC ,i1cc EI III I'rra: IT I "r Gue> 2n 2S O 25 2 l� 19n ®r 1 —tan E ,a ea oa 1 .r:nq r r -,T:= ,' ,, 7ca . r AM 1 t[r pc,..aue 25!_ CC �as C E * 1 SEC_ lal crI in / TC ^Elrctr:ct'loierarce N-1p"4: Inrc r nzuol" t .1,1ge 01 t i. , i p2 ASSEMBLED IN THE USA C UL US Certifications Efficient Safe Simple • Far cm.nnes that require UL •97%peak efficiency • Galvanic isolation • Patented automatic grid cetlifimtion(UL 1741/IEEE 15471 •CiptiCooln'active temperature valtage detedion* • Optional integrated AFCI management system •Integrated DC disconnecl switch functionality meets the requirements of NEC 2011 690.1 1 SUNNY BOY 5000-US / 6000-US / 7000-US / 8000-US Versatile performer with UL certification The Sunny Boy 5000-U5, 6000-US, 7000-1-15 and 8000-US inverters are UL certified and feature excellent efficiency. Graduated power classes provide flexibility in system design. Automatic grid voltage detection* and an integrated DC disconnect switch simplify installation,ensuring safety as well as saving time.These models feature galvanic isolation and can be used with all types of modules—crystalline as well as thin-film. `US Patent U57352549BI Technical dole Sunny Boy 5000-US Sunny Boy 6000-US Sunny Boy 7000-US Sunny Boy 8000-US EOBVA< ]daVAC =V AC 2a9VAC 240VAC DIVAr 1e41VAC 240V1L ZnVA[ RgVAC T1)VAC Input IDCI Max.recommended PV power I@ module STCI 6250 W 7500 W 8750 W 10000 W Max.DC power 1@ cosy=1) 5300 W 6350 W 7400 W B600 W Max.DC voltage 600 V 600 V 600 V 600 V DC nominal voltage 310V 310V 310V 345V MPP Voltage range 250 V-480 V 250 V-480 V 250 V-480 V 300 V-480 V Min.DC voltage/slart valtoge 250 V/300V 250 V/300V 250V/300V 300V/365V Max.input Current/per string(at DC disconnect) 21A/20A 25 A/20A 30A/20A 30A/20A 36 A @ combined terminal 36 A @ combined terminal 36 A @ combined terminal 36 A @ combined terminal Number of MPP hackers/fused strings per MPP hacker 1/4 IDC discanned) Output(ACI -_ AC nominal power 5000 W 6000 W 7000 W 76BO W 8000 W e Max.AC apparent power 5000 VA 6000 VA 7000 VA 76BO VA 8000 VA Nominal AC voltage/adjustable Zoe V/• 24o V/• 2nV/0 208 V/• 240 V/• 2nV/• 208V/• 24o V/• 2nV/• 24o V/• 2�v/• AC voltage range 183-229V 211-261V 244-"V 183-229V 211-24N N4-308V 183-229V 211-264V 244-"V 211-2MV 244-305V 5 AC grid frequency;range 60 Hz;59.3-60.5 Hz 60 Hz;59.3-60.5 Hz 60 Hz;59A-60.5 Hz 60 Hz;59.3-60.5 Hz _ Max.output current 24A 21A ISA 29A 25A 22A 34A 29A 25A 32A 29A Power factor(cos yJ 1 1 1 I Phase conductors connection phases 1/2 1/2 1/1 1/2 1/2 1/1 1/2 1/2 1/1 1/2 1/I - Harmonics <4% <4% <4% <4% _ Efficiency Max.efficiency 96.7% 96.8% 96.8% 96.9% 96.8% 97.0% 97.1% 96.9% 97.01. 96.3% 965% CEC efficiency 95.5% 95.5% 95.5% 95.5% 95.5% 96.0% 95.5% 96.0% 96.0% 96.0% 96.0% _ pratedian devices _ DC reversepolonty protection • • • • Integrated AFC(' o 0 0 0 3 , AC short circuit protection • • • • 9 Galvanically isolated/all-pole sensitive monitoring unit •/- •% •/- •% _$ Protection class/oveNolloge category I/III I/III /III /III - General data Dimensions lW/H/DI in mn(in] 470/615/240 (18.5/24/9) DC Disconnect dimensions(W/H/DI in mm(in) 187/297/190 (7/12/7.5) Pocking dimensions(W/H/DI to ram(inI 390/580/800 I I6/23/31.5) DC Disconnect packing dmemions lW/H/D)in man lint 370/240/280 (15/9/Ill Weight/DC Disconnect weight 64 kg 1141 IbI/3.5 kg 18161 66 kg 1145 16)/3.5 kg (8 lb) Paling weight/DC Disconnect packing weight 671,9 11471b)/4 kg (9 IbI 69 kg 1152 Ib)/4 kg (91b) Operalingtemperalurerange(full power)" -25'C...+45'C (-13`F...+113'F) Noise emission(typical) 44 dBIA) 45 dB(A) 46 dB(A) 49 dB[AI Internal consumption W night 0.1 W 0.1 W 0.1 W 0.1 W - Topology LF transformer LF transformer LF transformer LF transformer Cooling concept OptiCoal Optic.] Oplicool OptiCool _ Electronics protection rating/connection area NEMA 3R/NEMA 3R NEMA 3R/NEMA 3R NEMA 3R/NEMA 31Z NEMA 3R/NEMA 3R Features Display:text line/graphic •/- •% •/_ •/_ Interfaces:RS485/Bluetooth® 0/0 0/0 0/0 0/0 Warranty 10/15/20 years •/0/0 •/0/0 •/0/0 •/0/0 Certificates and permits Imore available on request) ULI741 (Second Ed.),ULI 998,UL1699B,IEEE 1547,FCC Part 15(Class A&B),CSA C22.2 No.107.1-2001 _ `For AFCI functionality specify SBXXXXUS-12 when ordering. For extended operating temperature range to-AD'C 1-40°FI,specify SBXXXXUS-11 or SBXXXXUS12 when ordering. •Standard features O Optional features -Not avoilable Data at nominal conditions NOTE US inverters ship with gray lids. `s Type designation SB SOOOUS SB 6000U3 SB 7000US Sit e000U3 _ s Efficiency curve SUNNY BOY 800GUS - ------ -------------_--- ------: Accessories - 98 96 _._..�. ck ......................................." a' 485USPBNRre aTPBINVNROy Bo E >:.., with C and Anlmne T 94r BT B ANTAR 9y 9a.5� biSwit. C953 �-la, 0e dt caeeert aed w {._ s dMwtieerariddedomber box reevemenceoed,.Wy 88COMBOSWflCH SBCB63R or5BC664245VI B6 -. EraIV, AIWVI3n0 V-IVI asoy SMAPrBalancerSet 00 0.2 0.6 0.4 0.8 1.0 Output power/Rated power 4 .............._-___-_-_--__- - Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC acme acme GODOWT OHTPU (ace) another great innovation by Wiley Electronics Faster, Cleaner Wiring! Captive screws for -E Durable UV easy installation -- resistant enclosure Your choice of wiring methods: • Weatherproof butt splices • DIN rail-mounted connector • 10x38mm fuse holders THWN-2 wires - �a s Accepts USE-2 or PV wire conduit from bottom or side _ J aC�ay s Equipment ground ��re conductor (Bare solid copper or Special seal for water- insulated wire only) tight enclosure • Simple array to conduit transition • Compatible with any conduit type - • Protective enclosure for connecting USE-2 or PV _ wire to THWN-2 wires • Two-piece enclosure for i unobstructed wiring • NEMA 3R rated for outdoor use Wiley Electronics L.L.C.®2007-All rights reserved 0 Please Recycle Specifications Input Wire Diameter Range 5.0-6.8mm[0.20.0.27in](10-12AWG USE-21PV Wire) Maximum number of Input conductor slots 9 Maximum number of PV strings 4 Maximum number of combined strings 4 Equipment Ground Conductor Type Bare solid or jacketed only Equipment Ground Conductor Diameter range 4.0-6.8mm[0.16.0.271n] Acceptable Conduit sizes 19.05mm,25.4mm[0.751n,1.01n] Internal Volume 1840cm 112m Internal Height 72.Omm[2.83in] Knockouts Side,Bottom Configurations Terminal Fuse ACE Part ACE Configuration Terminal Block Fuse Holder Combiner Grounding DIN Rail Number Black Internal Bus Bus Terminal ACE-PT Pass-Through using NIA NIA NIA NIA NIA NIA Butt SpiicesMire Nuts ACE-113 1-String Pass-through 2 NIA NIA NIA 1 1 ACE-211 2-String Pass-through 4 NIA NIA NIA 1 1 ACE-313 3-String Pass-through 6 NIA NIA NIA 1 1 ACE-413 4-String Pass-through 8 NIA NIA NIA 1 1 ACE-2C 2-Strings Combiner 4 2X 2-Pole Not required for 2- NIA 1 1 string combiner ACE-3C 3-Strings Combiner 3 1X 3-Pale 3 1X 3-Pole 1 1 ACE-4C 4-Strings Combiner 4 1X4-Pole 4 1X4-Pole 1 1 ACE Mounting Bracket Made of lightweight,corrosion resistant anodized aluminum. Available in Black or Clear Anodize. Mounting Bracket Assembly Includes: I ACE Mounting Bracket 4X Mounting Screws - 2X Bonding Washers PO Box 361 144 Peoples Rd Saugerties, NY 12477 Tel: (845)633.2065(845)247.3852 Websits:www.we-lfc.com -acme pv peripherais- Wiley Electronics LLC.O 2007-AII rights reserved 441 Please Recycle C?0,. I I I Pip Solar Meter As consumers become more environmentally aware of their energy consumption and carbon footprint, the interest in and use of solar power is on the rise. Itron's revenue-grade Solar Meter is ideal for monitoring the production of residential and commercial solar photovoltaic (PV) systems. The meter collects, stores and uploads the PV system's production data to the solar solution provider over an existing cellular network link that is fast, reliable and secure. Itron's cellular meter adheres,at minimum, expensive than other available monitoring doesn't require entrance into the house to the stringent ANSI C12.20 5.5.2.5 systems.Using our technology,you can or property accuracy class CA 0.5 standards — benefit from: » Immediate notification of production measuring inverter production with up to » Revenue-grade meter accuracy issues through alarms 99.50/ accuracy,regardless of inverter or ANSI certification and the highest level » Over-the-air upgrades to ensure your panel type.Simply put,Itron's Solar Meters of security available(meets federal meters have the latest features and are the most accurate and reliable meters security standards) functionality,no on-site visits required available —and are already trusted by leadingelectrical utilities around the U.S. » Unparalleled reliability and proven architecture deployed by leading utilities Simple and Reliable And because our meters can he installed in Itron Solar Meters can monitor any type of a simple"plug and play"fashion with utility- » Low-cost,one-piece installation that solar energy system production with 99.8% standard installation techniques,installation requires significantly less labor accuracy regardless of inverter or panel and activation is streamlined — meters can » Standard meter connections — no type.Information can be stored for up to report production data to the solar provider custom parts or wiring 90 days. in as little as 45 minutes. > Certified with network carrier for the Production data is stored on the meter and highest possible reliability and fast data uploaded automatically over the cellular BENEFITS OF CELLULAR transfer with immediate accessibility network to the collection system.Solar SOLAR MONITORING u Remote disconnect switch option providers retrieve production data via an In addition to quick and easy installation, helps with non-payment issues and industry-standard format or secure XML file Itron Solar Meters are significantly less transfer from the collection system. } R r t � �� ■■■ �► Emilio Emmons Web Prasentment Solar Provider \ N C Utility Utility Disccnnect Meter Switch How it Works Smal'Meter cernmunicaticn over cellular F_t,?od:; Installation 1 hour)as defined by the solar provider. the Solar Meter will remain backward A Solar Meter plugs into a number of Production data can be stared in the compatible so your investment remains energy industry-standard ANSI plug-in meter for up to 90 days.The Solar Meter protected for the long term. bases. For most residential installations module provides the solar provider with a of 200 amps or less,a.widely available vast quantity of meter alarms that provide Cloud and Hosting Services standard Form 2S is used. Installing the information about the installation. Itron offers a hosted server so that solar Solar Meter in-line with the service panel providers don't have to worry about adding feed allows the solar provider to utilize the Network Connectivity "yet another system"to manage and meter's remote disconnect capabilities Itron Solar Meters are truly"plug and play" operate with in-house staff.With our cloud to ensure safety during utility outages or devices that use a cellular connection for and hosting services,production data is modifications to the main service panel. data transfer.Using a Solar Meter,the collected and provided via web services or Every Solar Meter is enabled to accept installer has flexibility to select either AT&T XML files to the solar providers'in-house aver-the-air firmware upgrades,ensuring or Verizon as the commercial network systems or web-portal systems. the meter always has the latest updates. of choice to ensure the highest quality network connection available.Our meters SPECIFICATIONS Data Collection use 3G connectivity for high-speed,secure Meter compatibility and specifications All Itron Solar Meters collect interval data(at and reliable communications.As cellular available upon request. intervals typically between 15 minutes and data networks incorporate new technology, Itron is a global technology company We build solutions that help utilties CORPORATE HEADQUARTERS measure,manage and analyze energy and water.Our broad product portfolio 2111 N Molter Road includes electricity,gas,water and thermal energy measurement and control Liberty Lake,WA 99019 technology;communications systems;software;and professional services. USA With thousands of employees supporting nearty 8,000 utilities in more than 100 countries,Itron empowers utilities to responsibly and efficiently manage Phone: 1.800.635.5461 energy and water resources. Fax: 1.509.891.3355 Join us in creating a more resourceful world;start here:www.itron.com. or ptlevuacy pl.pnp arpressly d s,.',,no b'I ly b ,. a, ,,,rims... such male+'els.ne wa^amy or an,l mu c(I axe vertu,rn sralu my.Pclptl'.rJ hp rcl rm V,1A Te mar zl:a'ron L,In ,, 'ol[hdNl IV ],1.,rner ech+r m,I[N_r: re.vor�I�[-JvprP =e -wr SIP rerp IL�tFn:.'ra [ 'J e_e*erkal aln alp Gr_UV,J I:II f !rp_A1 ly WFi '01 l h 13 lei?, trio STRUCTURAL ENGINEERS January 15, 2014 a�EssioN -4� NNEiq q� h 29�H Fyn' P w m K A Nu.6 79 �grsJRUCTUR�"a}��P F OF CAS Attn.: Engineering Department, Re: Engineering Certification for UniRac's SolarMount Code-Compliant Installation Manual 227.3 PZSE, Inc.-Structural Engineers has reviewed UniRac's "SolarMount Code-Compliant Installation Manual 227.3 published October 2010 and specifically"Part 1. Procedure to Determine the Design Wind Load", and "Part II: Procedure to Select Rail Span and Rail Type". This letter certifies that the structural calculations contained within UniRac's "SolarMount Code- Compliant Installation Manual 227.3 published October 2010 are in compliance with the following Codes 1. 2012 International Building Code, by International Code Council, Inc. 2. 2013 California Building Code 4v California Building Standards Commission 3. 2010Aluminum Design Manual, by The Aluminum Association If you have any questions on the above, do not hesitate to call. Sincerely, Paul Zacher, SE - President 8137 Sunset Avenue,Suite 120 • Fair Oaks,CA 95628 • 916.961.3960 • 916.961,3965 f • WWWRSI.CoN GroundTrac° The Original "Top-Down" PV Mounting System for Ground Applications Benefits of GroundTrac® Patent#6,360,491 • Industry's preferred low cost and easiest to install ground mount system - Used for kW to Multi-MW projects • Patented ground mount system ships from available stock • Proprietary Drop-N-Lock rail insert drops in and locks ProSolar GroundTrac® rails in place • Over 10 years of ProSolar's proven design • Pre-engineered and tested for easy permitting • No cross-bracing required R�Sb - professional SOLAR products See 9elo,v �112" 3"MIn,� ol:oa"ee aepe.es 42" ; n ma rz l (see angle c art7 2 Assemble re-usable grade stakes(ProSolar metal grade stake kit shown). Recommend 2"x 4"vertical support. Dig footings. Use 1/2" drill bit and 9/16" socket to attach grade Lateral (left to right) footing spans stake kit to 2" x 4". Attach 1" x 4" wooden horizontal listed on page 4 (bottom). Front to support using 3-1/2" (min.) C-clamps. Grade stake kit rear footing spans listed in angle includes: 24" threaded metal stake, aluminum spacer charts on page 4 (top). Refer to block, bolt and washer. engineering reports for footing specs. 3 Place horizontal 1-1/2" schedule 40 galvanized water pipe with slip-on Hollaenderf Tees. Adjust C-clamps as necessary to level pipe. I I" i I � I I 1 1 I i 2„ it 4 Measure vertical pipe lengths, allowing 2" (min.) from bottom Insert vertical pipes into of footing to avoid pipe contact tees and fasten lower tee with moisture. set screw. Center pipes in footings by sliding left or right. Pour or pump mixed concrete into footings. Rest rail on top of horizontal pipes. Run string level --- on top or bottom to align tops of support rails. Fasten rail in place by using GroundTrac@ drill guide along top and bottom of horizontal pipes. Drill U-bolt locking holes in place. Leave at least one drill guide attached after drilling to keep rail in place. �2'Kn. ' J GroundTracg' Drill Guide l Base and Drill Bit. e Install at least one rail every 10, for proper pipe ` spacing. Insert U-bolt into locking rail holes and place Optional snout Drop-N-Lock insert into the rail, Remove remaining drill guide and proceed with other rails. Remove grade stakes. Tighten all tee set screws to 17 ft-lbs with torque wrench. Install remaining rails, evenly tightening U-bolt nuts. I Pre-assemble clamping hardware and install solar EZ rail modules and EZ rail endcaps. Completed endcap _ Install 1-1/2" plastic pipe installation. endcaps for schedule 40 pipe as necessary. Front 124" and 136" Rail to Rear 124"x 2-1/2"Support Rail Array Footing Angle Chart Supports up to (3) 39.5"Wide Modules Angle Distance 00 84" 30°, So 84" 10° 83" 15- el" 20° 39.5" 25° 76" ed 15°y -- - _ - 300 73" 8p Q�+. - 10. �- 124" 73- __- �- 2-1/2„ - -_ _- _. 76„ c 84" f /30"Max I_ _ -.--.- 79., -. 60"Max from top _ -. _ _.-.-- 81" --- -___ from top of footing --------.--- 83- ------- of footing 84" 136"x 2-1/2" Support Rail —------ 84"——-----�— Supports up to (4) 32.5"Wide Modules r i 124"and 136"Rail ' Refer to engineering report for footing specs Front to Rear 164" Rail Angle Distance Angle Chart 200 F _._. 2-1/2" 0° 108" 84" 5° 1081, 35q 10° 106" e 164"x 3"Support Rail 15° 104" Fixed t -1.0° Supports up to(4) 39.5"Wide Modules 20' 101" 0. 39.5" _ 106" 108" I" 164' -1 164" Rail 3" II 108 ' Refer to engineering report for footing specs LJ GroundTrac® Rail Sizes 124" x 2-1/2" 136" x 2-1/2" 164" x 3" Number of Modules (3) 39.5" wide (4) 32.5"wide (4) 39.5" wide modules modules modules Lateral (left to right) footing 10' 10' 8' span (max) non-snow load Lateral (left to right) footing 6' 6' Not snowload span (max) 30 Ib/ft2 snowload rated Front to back footing spacing See Angle Chart See Angle Chart See Angle Chart Pre-slotted rails at: 84"on Center 84"on Center 108" on Center Ph°t°courtesy:Neonate Pir&Elelric Professional Solar Products (ProSolar) • 1551 S. Rose Ave., Oxnard, CA 93033 805-486-4700 • www.prosolar.com BProfessional Solar Products, Inc March 2011. GroundTrac@ is a registered trademark and covered under pat.#6,360,491 Product Data Sheet DU221 RB Safety Switch , 30A, 240VAC, Non-Fusible, General Duty, 2-Pole ❑] SOUARE 0 by Schneider it c k;... List Price $177.00 USD Availability Stock Item:This item is normally stocked in our distribution facility. Technical Characteristics Wire Size #14 to#8 AWG(AI/Cu) Action Single Throw Ampere Rating 30A Approvals UL Listed File Number E2875 Enclosure Type Rainproof and Sleet/lce proof(Indoor/Outdoor) Enclosure Rating NEMA 3R Factory Installed Neutral No Maximum Voltage Rating 240VAG Terminal Type Lugs Disconnect Type Non-Fusible Mounting Type Surface Type of Duty General Duty Number of Poles 2-Pole Shipping and Ordering Category 00106-Safety Switch,General Duty,30-200 Amp,NEMA3R Discount Schedule DEtA GTIN 00786901490340 Package Quantity 1 Weight 4.62 lbs. Availability Code Stock Item:This item is normally stocked in our distribution facility. Retumability Y Country of Origin MX As standards..specifications,and designs change from time to time,please ask for confirmation of the information given in this document. ©2009 Schneider Electric.All rights reserved. Schneider VEfectric ,AaW. =,=P 1 BUR' NDY` WEEB-BONDING JUMPER -== The WEEB Bonding Jumper is used to create an electrical connection between two pieces of anodized aluminum, galvanized steel, or any electrically conductive metal which has been mechanically spliced. Long spans of mounting rails are sometimes constructed from two shorter rail sections. Manufacturers may recommend that a floating splice be used to allow for thermal expansion. A floating splice is rigidly attached to only one rail, and allows the rails to expand and contract in line with each other. In such cases, via NEC code, it is also necessary to make an electrical splice, which can be done with a WEEB Bonding Jumper. The Bonding Jumper is constructed of tin plated, braided copper wire with a WEEB attached at each end of the Jumper. The WEEBs provide a reliable, gas tight electrical connection, and the braided copper wire allows for thermal expansion. The examples below illustrate two ways to install the WEEB Bonding Jumper. Catalog Item# Length Hole Hardware Torque WEEB-BNDJMP6.7 30020147 9.0"overall, 114 inch hardware- 8.3"hole-to-hole on center included unassembled 0.257" WEEB-BNDJMP6.7AS 30020117 9.0"overall, 1/4 inch hardware- 8.3"hole-to-hole on center included assembled 10 ft. Its. w/Penetrox-A WEEB-BNDJMP8.0 30020121 6.0"overall, M8 or 5/16 inch hardware- on threads 5.3"hole-to-hole on center 0.315" not included WEEB-BNDJMP8.2MS 30020122 10.0"overall, M8 or 5/16 inch hardware- 9.2"hole-to-hole on center not included Unirac SolarMount SnapNRack Customer Service Department 7 Aviation Park Drive �j Londonderry, NH 03053 ' 1-800-346-4175 Fntertek 1-603-647-5299 (International) 3098177 92012 BURNDY LLC www.we-Ilc.com HUBBEL.L. �' BURNOT WEEB-LUG The WEEB Lug consists of a WEEB (Washer, Electrical Equipment Bond), lay-in lug, and hardware. It is used with one solid or stranded copper wire (14AWG to 6AWG), or two copper wires (12AWG to 10AWG) to provide a continuous ground on roof or ground mounted solar systems. Unlike traditional lay-in lugs, the WEEB Lug does not require surface preparation on rail or module to install. The WEEB Lug is installed using stainless steel mounting hardware. When the hardware is tightened the WEEB's specialized teeth embed into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. The tin-plated Lug assures minimum contact resistance and protection against corrosion. Copper wire is clamped by a 1/4-28 stainless steel screw, which is horizontal to the tang for easy access when mounted under a PV module. The low profile of the WEEB Lug allows it to be installed in a variety of positions. Catalog Item# L x W x H Hole Hardware Torque WEEB-LUG-6.7 30020109 1.60"x 0.71"x 0,47" 1/4 inch hardware- included unassembled 0.266" 7 ft. lbs.for WEEB-LUG-6.7AS 30020110 1.60"x 0.71"x 0.47" 1/4 inch hardware- included assembled terminal screw WEEB-LUG-8.0 30020111 1.60"x 0.87"x 0.47" M8 or 5/16 inch hardware- 10 ft. lbs.for not included mounting WEEB-LUG-8.21MS 30020115 1.60"x 0.71"x 0.47" M8 or 5/16 inch hardware- hardware 0.323" not included w/Penetrox-A WEEB-LUG-15.8 30020112 1.60"x 0.71"x 0.47" M8 or 5/16 inch hardware- on threads not included Material: 304 stainless steel, tin-plated copper, outdoor rated Low profile design — Multiple equipment ground conductor allowance: One 14 AWG to 6 AWG or two 10 AWG, two 12 AWG Listed to ANSI/UL 467 by Intertek ETL I, Customer Service Department 7 Aviation Park Drive Londonderry, NH 03053 ", w 1-800-346-4175 mtenek 1-603-647-5299 (International) 3098177 ©2012 BURNDY LLC www.we-llacom 4`111LIBBELL�